This generally includes, but is not limited to, safety glasses, face shields, hard hats, safety shoes, insulating (rubber) gloves with leather protectors, insulating sleeves, and flame-resistant (FR) clothing. Do not work alone if hazardous conditions exist. ā ā Need Help? www.buddy.com/support...
Buddy Ohm and Ohm Link units via RJ45 cable, but is optional for real power (high accuracy). If the Link can also be wired to an Ohm Sense unit as well. will run on batteries in a single-phase installation, have (3) AA lithium Ion batteries per Link.
After a minute, the light should change to solid green. Buddy Ohm is the main base unit which other Note: If the light doesn’t become solid blue, that means devices communicate with. Buddy Ohm connects there is no cellular connection and the Ohm is unable via cellular network to Buddy Cloud.
If required, contact a qualified electrical expert. Locate the electrical panel. Open the panel cover using the necessary tools, if needed. polarity Use the required amperage CT clips and install to the desired circuit(s) that you want to measure. Need Help? www.buddy.com/support...
Mounting Information Using the magnetic back cover on Link, mount the Link on a metal surface. Note: If you are seeing a low signal strength icon next to your device, try repositioning it closer to the Buddy Ohm. Need Help? www.buddy.com/support...
Ohm Installation Guide | Installing Ohm Sense Installing Ohm Sense The Ohm Sense wirelessly measures temperature and humidity and communicates with Buddy Ohm over radio frequency (433 Mhz). Open the top cover of the Sense. Install the double (AA) batteries.
Ohm Installation Guide | Installing Ohm Pulse About Ohm Pulse The optical Ohm Pulse sensor is used to detect light pulses from digital meters and works with Buddy Ohm, Ohm Link and Ohm Sense units. Parameter Notes Operational Temperature Range...
Page 9
Ohm Installation Guide | Installing Ohm Pulse Installation Notes DIP switch 1 MUST be ON (Ohm Link and Ohm Sense). The switch is located inside the Ohm Sense and Ohm Link. Open the top cover of the Ohm Link and Ohm Sense...
If you don not have access to the Ohm Portal you can ā ā This means a CT clip was installed improperly, ensure cycle the Buddy Ohm’s menu by pressing the front ā ā CTs have polarity (facing the proper direction).
Page 11
Adelaide Level 2, 333 King William Street Adelaide SA 5000, AUS +61 8 8121 8004 Seattle 217 Pine Street, Level 700 Seattle, WA 98101, USA +1 (206) 745-9077 Buddy.com...
Need help?
Do you have a question about the Ohm Sense and is the answer not in the manual?
Questions and answers