  • Page 2 Benefits and Technical Information SUN-2242 is an Ethernet I/O controller with build-in web server. It has 2 digital inputs, 2 analog inputs, 2 relay outputs and 1-Wire input for up to 5 temperature & humidity sensors. SUN-2242 can be controlled and monitored over any TCP/IP network and Internet by web browser or any specialized monitoring software by SNMP v1 and v2 protocol.
  • Page 3: Technical Information

    Technical information Power requirements Input Voltage: 12VDC / 0.5 A (adapter) Power Connector: Jack Ø5.5 x 2.0 / 10mm Ethernet Interface Connector: 8-pin RJ45 Magnetic Isolation Protection: 1.5 kV (built-in) Number of ports: 1 Speed: 10/100 Mbps, Auto MDIX Protocols HTTP, DHCP, SNMP v1 and v2, SNTP, SMTP, SMTP TLS, XML Operating conditions Operating temperature: -20 to +70 °C...
  • Page 4: Device Connection

    Warranty – 2 years Device Connection Connect the SUN-2242 to 10/100 Mb/s network. Use a classic TP patch cable for connection to switch, router or to PC. If the Ethernet connection is OK, the ACT and LINK indicator should light up and then ACT indicator blink according to network data transfer.
  • Page 5: Installation Guidelines

    SUN-2242 controller must be installed by qualified personnel. Controller must not be installed directly outdoors. SUN-2242 must not be used for medical, life saving purposes, or for any purpose where its failure could cause serious injury or the loss of life.
  • Page 6 Login Page -  access to the SUN-2242 is protected by name and password  Status Page - Monitoring parameters S U N - 2 2 4 2 U s e r M a n u a l v 1 . 1...
  • Page 7 Status page has 4 sections – “Digital inputs”, “Analog inputs”, “Outputs” and “Sensors”.  Digital Inputs section can be used for monitoring sensors in “dry contact”(volt free) mode - motion PIR sensors, Water Leak sensors, Water level sensors, Door/window sensors, Smoke detectors. One side of the sensor is connected to IN1 or IN2 terminal and the other is connected to GND terminal.
  • Page 8 Device name – up to 15 characters. MAC address – hardware address of the device. It is unique and cannot be changed. IP address – The SUN-2242 IP address configuration can be either static or set through DHCP. Enable DHCP - allows device automatically obtain a valid IP address from Gateway Gateway –...
  • Page 9: System Settings

    Time zone – offset of time zone with respect to that of the NTP Server. Interval – Automatic synchronization interval. This option allows the user to specify how often the time on the SUN-2242 will be synchronized with the NTP server Uptime - time since SUN-2242 was last powered.
  • Page 10: Account Settings

    Sensor Settings This page is used to configure temperature and humidity sensors. Up to 5 x 1-Wire sensors can be connected to the SUN-2242. Every 1-Wire sensor comes with a unique ID. After a sensor is connected must to find it by click on the button "Find sensors".of Status web page.
  • Page 11 Name – can be entered a description up to 15 characters ID – unique number for each sensor Type – Temperature or Humidity Measured value – the value that sensor is reading. Lower range - value below this range are considered to be “incorrect” and alarm event occurs Upper range - value above this range are considered to be “incorrect”...
  • Page 12: Snmp Settings

    SNMP Settings The Simple Network Management Protocol - SNMP, is a commonly used service that provides network management and monitoring capabilities. SNMP offers the capability to poll network device and monitor data. SNMP is also capable changing the configurations on the host, allowing the remote management of the network device.
  • Page 13: Email Settings

    Email Settings Mail server address can be set by hostname or IP address. SUN-2242 supports TLS 1.0, TLS 1.1 and TLS 1.2 encryption. This ensures successful send emails with most of the public email servers . When TLS encrypted connection is selected, the connection to the email server will be securely.
  • Page 14 Inputs / Outputs Settings Name - this text field describes the function of the selected input or output. Up to 15 characters may be entered. Digital inputs – used for direct connection of volt-free contacts. One side of the contact is connected to Input1 or Input2 and the other side is connected to terminal in the middle –...
  • Page 15 Local Relay Outpus settings can select whether the local relay to be activated manually by click button “ON/OFF” or automatic by any of the following parameters: Digital Input 1 Digital Input 2 Analog input 1 Analog input 2 Sensor 1 Temperature Sensor 1 Humidity Sensor 2 Temperature Sensor 2 Humidity...
  • Page 16: Dynamic Dns

    SUN-2242 supports Dynamic DNS services from DynDNS and No-IP. Firmware update On this web page you can update SUN-2242 with the new firmware. Please keep in mind not to power off the device during the update! It can damage the device! S U N - 2 2 4 2 U s e r M a n u a l v 1 .
  • Page 17: Application Examples

    Application Examples Remote monitoring application S U N - 2 2 4 2 U s e r M a n u a l v 1 . 1 P a g e...
  • Page 18 S U N - 2 2 4 2 U s e r M a n u a l v 1 . 1 P a g e...
  • Page 19 Control of 220V AC / 20 A motor using external relay S U N - 2 2 4 2 U s e r M a n u a l v 1 . 1 P a g e...
  • Page 20 S U N - 2 2 4 2 U s e r M a n u a l v 1 . 1 P a g e...