AY-B9250BT Professional Fingerprint Reader User Manual...
Page 2
ROSSLARE. ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
AY-B9250BT User Guide 1. Before Getting Started 1.1. Safety Notes Warning Do not operate the terminal with wet hands, and pay attention not to let any Keep the terminal away liquid such as water enter from inflammables. inside the terminal.
AY-B9250BT User Guide 1.2.1. FRONT BLE embedded State LED Camera Function KEY (F1~F4) Speaker Fingerprint Sensor Card Sensor (EM/SC/HID) USB assist device (UDL10) connection...
AY-B9250BT User Guide 1.2.3. Input / Output 1.2.3.1. Cable & Connector 1.2.3.2. Pin Details Line color Label Explanation IN/OUT Note number (Line name) ORANGE Inside open Connect to Exit button YELLOW DoorMonitor0 Sense door state(DM0) GREEN DoorMonitor1 Sense door state(DM1)
AY-B9250BT User Guide GRAY LOCK1_COM Lock1 COM terminal BROWN L1NC LOCK1_NC Lock1 NC terminal WHITE L1NO LOCK1_NO Lock1 NO terminal PURPLE LOCK2 Lock2 terminal BLACK Ground connection (Lock connecter) BLACK PGND Power GND Power supply ground connection (Lock power) BLACK...
AY-B9250BT User Guide 1.3.1. Initial Screen When powering on at first, the screen is displayed as follow. State icon Operation Mode TNA Mode Date and Time 1.3.2. Icons NONE : No use network : LAN line is disconnected. Server connection...
AY-B9250BT User Guide ENABLE Category choice (ENABLE or DISABLE) DISABLE 1.3.4. Main Screen Operating in Exclusive mode Initial Screen Operating in Network mode Initial Screen Operating in Dummy mode Initial Screen Operating in lock mode (Reject all users authentication) Menu of Initial Screen...
AY-B9250BT User Guide Waiting for Card Input Waiting for Fingerprint Input Waiting for Admin App registration Upgrading firmware 1.4. LED information during operation Operating state Remark Normal Alarm ON or Flash ON (Maintain during authentication time) Authentication Failure OFF...
AY-B9250BT User Guide 1.6. Buzzer guide announced during operation Buzzer Sound State Explanation Key touch -Pressing key or reading card Beep Card tag -When inputting fingerprint, input has Fingerprint touch been completed and hands can take off. If authentication fails or the user's input is...
AY-B9250BT User Guide If your hands are dry, you can blow your breath on the system to operate it more smoothly. For children, too small or unclear fingerprints may be difficult or impossible to use. They need to register a new fingerprint every six months.
AY-B9250BT User Guide 2.2. Diagram 2.2.1. Single Type (Door Lock) Close BLE 2.4G Lock control Open Mobile App Door Lock 2.2.2. Single Type (Lock Controller) Close RS485 BLE 2.4G Open Mobile App Lock Controller 2.2.3. Dummy Type Lock/Open RS485ID Lock/Open...
AY-B9250BT User Guide 2.2.4. Network Type (Door Lock) Close BLE 2.4G Lock Control Open Mobile App Ethernet Door Lock Ethernet Internet Server 2.2.5. Network Type (Lock Controller) Close RS485 BLE 2.4G Open Mobile App Lock Controller Ethernet Ethernet Internet Server...
AY-B9250BT User Guide 3. Environment Setting 3.1. Checkpoints before Environment Setting 3.1.1. Menu Press F4 long until the menu screen is displayed. It is available to enter the menu without authentication because the manager doesn’t register when shipping the product.
AY-B9250BT User Guide 3.1.3. How to access the menu without administrator authentication This is the method to enter the Menu in exceptional cases such as losing your administrator card that is registered in the terminal or inability to make a fingerprint authentication because of absence of administrator.
AY-B9250BT User Guide 3.1.5. Default Setting Category Default setting MENU > NETWORK MENU > NETWORK > USE > AUTH MODE MENU > NETWORK > USE > TERMINAL ID MENU > NETWORK > USE > TERMINAL > STATIC MENU > NETWORK > USE > TERMINAL > STATIC >...
AY-B9250BT User Guide 3.1.6. Setting guide for Network Configuration 3.1.6.1. Single Type (Door Lock=STRIKE) Menu position Possible setting MENU>NETWORK> NO USE MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE STRIKE/OK MENU>EXT DEVICE>DOORLOCK>DM0 N/O or N/C MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE NONE MENU>EXT DEVICE>DOORLOCK>DM1 NONE MENU>EXT DEVICE>DOORLOCK>DM2 NONE MENU>EXT DEVICE>RS485>TYPE NONE 3.1.6.2.
Page 22
AY-B9250BT User Guide (Use : When only downloading DB) MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE NONE MENU>EXT DEVICE>DOORLOCK>DM0 NONE MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE NONE MENU>EXT DEVICE>DOORLOCK>DM1 NONE MENU>EXT DEVICE>DOORLOCK>DM2 NONE MENU>EXT DEVICE>RS485>TYPE MCP040 MENU>EXT DEVICE>RS485>DEV ID Use in 1~7 3.1.6.6. Network Type (Door Lock=STRIKE) Menu Position Possible setting MENU>NETWORK>...
3.2. Access and Registration between Rosslare Bio9000 and terminal 3.2.1. Install Rosslare Bio9000 When shipping the product, it comes with a CD to install Rosslare Bio9000 on your PC. For installation guide, please refer to the relevant document. 3.2.2. Execute Rosslare Bio9000 If executing the program, login screen is displayed.
AY-B9250BT User Guide If login is successful, the screen is displayed as follows. Set in terminal 3.2.3. In order to connect the terminal to the server, set to the network mode and set the information. Move to MENU > NETWORK > USE > TERMINAL and check whether lower information is correct or not.
3.2.4. LAN connection in terminal At first, you can see the unregistered state because the terminal is not registered. 3.2.5. Register the terminal in Rosslare Bio9000 Select the unregistered terminal and press Registration button to activate the screen below. Enter device name and explanation to press OK.
Page 26
AY-B9250BT User Guide If the registration is successful, the screen is displayed as follow. For more details about Rosslare Bio9000 operation, please refer to the guide document.
AY-B9250BT User Guide 3.3. Menu Configuration The whole menu is composed of seven, and main characteristics are as follows. Menu Submenu1 Submenu2 Submenu3 USER USER USER ADMIN INPUT ID *Authentication Type Card MCARD *Authentication Condition ※ MCARD is OR condition only.
Page 28
AY-B9250BT User Guide TERMINAL ID TERMINAL ID STATIC STATIC DHCP Subnet mask Gateway DHCP SERVER SERVER Port No OPTION ATTEND TYPE NONE M1 F1~F2 M2 F1~F4 M3 F1~F49 AUTO TNA SCREEN LANGUAGE ENGLISH(0) KOREAN(1) INDONESIAN(2) MULTILINGUAL(3) ARABIC(4) SPANISH(5) PORTUGUESE(6) FRENCH(7)
Page 29
AY-B9250BT User Guide AUTH TIME BEEP VOICE BLE READY TAMPER NO ALARM ALARM DOOR LOCK LOCK1 *TYPE DEVICE Not Use Strike/OK Indication Motor1 Schedule alarm *OPEN TIME 3[1~20sec] LOCK2 * TYPE NONE Fail Indication Motor2 Schedule alarm * OPEN TIME...
Page 30
AY-B9250BT User Guide WIRE-OUTPUT *TYPE NONE WIE26BIT WIE34BIT CUSTOM *SiteCode *More Information CARD STATE DB INFO USER CNT: USER MAX: ADMIN: FP CNT: FP MAX: CARD CNT: CARD MAX: M.CD CNT: LOG CNT: LOG MAX: NETWORK TID: xxxx NET: YES, MODE:TN...
AY-B9250BT User Guide 3.4. USER Menu USER menu has the feature as follows. Category Explanation Use to add user and admin with various certification conditions. AUTO ADD Use to add Card or Fingerprint user automatically. MODIFY Use to add certification conditions, card or fingerprint of registered user.
Page 33
AY-B9250BT User Guide ADMIN Available to add and delete user. Available to access menu and modify it. When selecting the administrator, the screen is displayed as follows. 3.4.1.2. AUTH TYPE There are FP (Fingerprint), Card, and MCARD (Mobile card) in the menu.
AY-B9250BT User Guide 3.4.1.4. INPUT CARD When you check Card as AUTH TYPE, you need to follow steps as below. If you input CARD on Waiting state, registration completes and INPUT OK screen is displayed. EM CARD ex) Card No.(5byte): 08h 01h 16h 1Dh D6h Card Format Card No.
AY-B9250BT User Guide 3.4.2.2. AUTO ADD This is the menu when registering the users continuously only by card. After inputting the card, INPUT OK is displayed on the screen. If you want to add the other user, select 2. YES, and register the user.
If you want to see the authentication log data in Standalone mode, move RECOVERY > BACKUP > LOG EXPORT from main menu, download it in USB through UDL module and check it by Rosslare Bio9000 program. Network Mode This is the operation mode by communicating with the server and it can control the functions of the terminal by the remote-control.
AY-B9250BT User Guide processing is done in the terminal or the server when user-authentication. It is a valid setting only when using the network. All authentication log is sent to server through the network. AUTH MODE Explanation Server/Terminal Server Terminal After trying to do server authentication at first, terminal authentication is processed.
AY-B9250BT User Guide Network setting in the terminal can be set in Static IP and DHCP. STATIC: Set the value as a user wants. DHCP: Allocated flexibly. (It can be operated normally when using the router supporting DHCP.) If STATIC is used, it is used when setting IP, Subnet mark and Gateway address of the terminal.
AY-B9250BT User Guide Category Explanation ATTEND TYPE AUTO TNA SCREEN LANGUAGE SHOW ID USER LOGO USER ID LEN DATE SAVE LOGO SAVE IMAGE SAVE TIMEOUT RESULT NET ERROR PING LOCKING NO USE / USE 3.6.1. ATTEND TNA related menu is configured.
AY-B9250BT User Guide Mode Explanation NONE F00 is only displayed in default screen. F1~F2 F1~F2 Function Key is recognized and F01, F02 are displayed in default screen. F1~F4 F1~F4 Function Key is recognized and, F01, F02, F03, F04 are displayed in default screen.
Page 41
AY-B9250BT User Guide default screen. 3.6.2.1. Language It is used to change the voice language and menu text displayed on the screen. Voice guidance is available in English, Korean, Indonesian, Thai, Arabic, Spanish, Portuguese, French, Russian, Farsi, Japanese, and Chinese.
Page 42
AY-B9250BT User Guide Category Explanation NO USE Use basically the provided default image Use the customer’s logo image To use the customer’s logo image, you should update the customer’s image through the server first and then the customer’s image is displayed in the default screen.
AY-B9250BT User Guide 3.6.2.5. DATE It is used to select the order of Year, Month and Day displayed in the default screen. YY: Year MM: Month DD: Day Through SETTING, you can set current Year, Month, Day and Time. 3.6.3. SAVE It is the menu including the function related to SAVE.
AY-B9250BT User Guide 3.6.3.2. IMAGE SAVE It is used to set whether to save the captured photo from camera when authentication successes or fails. The default setting is Fail. 3.6.4. TIMEOUT It is the menu that has the setting related with timeout.
AY-B9250BT User Guide 3.6.4.3. PING It sets the cycle that terminal sets PING command to the server. The setting range is available for 30~255 seconds. 3.6.5. LOCKING Locking mode is the function that it rejects the authentication of all users until the administrator enters the menu and releases the locking mode.
AY-B9250BT User Guide 3.7. INT DEVICE Menu INT DEVICE menu has the features as follows. Category Explanation FP SENSOR 1:1 LEVEL 1: N LEVEL LFD LEVEL AUTH TIME BEEP Set Beep Sound. VOICE Set Voice Sound BLE registration mode TAMPER Set the alarm when opening terminal case.
Page 47
AY-B9250BT User Guide 3.7.1.2. 1: N LEVEL It is the authentication level used when it tries 1: N fingerprint authentication. 3.7.1.3. LFD LEVEL It sets LFD LEVEL to prevent the duress fingerprint. If setting LFD LEVEL higher and higher, the ability to prevent the input of duress fingerprint produced by rubber, paper, film, and silicon etc.
AY-B9250BT User Guide 3.7.2. BEEP It informs key touch, authentication success, and failure as beep and sets the beep level. The beep level is available from 0 to 3. VOICE 3.7.3. It supports the notice such as authentication success/failure and authentication retrial. It sets the authentication level.
AY-B9250BT User Guide If selecting 1. NO ALARM, even if disassembling the terminal, the alarm doesn’t sound but icon is displayed. If selecting 2. ALARM, icon displays and the beep sounds in at regular intervals. 3.8. EXT DEVICE Menu EXT DEVICE has the features as follows.
Page 50
AY-B9250BT User Guide 3.8.1.2. LOCK1 OPEN TIME It sets the time to give the signal when LOCK 1 sets 2. STRIKE/OK. Strike type means the time from opening to locking the door after authenticating. The default value is 3 seconds and the input range is 1 to 20 seconds.
Page 51
AY-B9250BT User Guide 3.8.1.6. DM0(Door Monitor 0) is the input port and it is used to detect the signal state of door open. 3.8.1.7. DM1(Door Monitor 1) is the input port and it is used to detect the signal state of lock.
AY-B9250BT User Guide 3.8.2. RS485 It is the setting for the device with RS485 communication to interface with external. 3.8.2.1. TYPE TYPE Explanation NONE It doesn’t use RS485. LC010 Lock Controller It controls LOCK through the other external module. LC015 Lock Controller It controls LOCK through the other external module.
Page 53
AY-B9250BT User Guide WIEGAND supports each one of Input port and Output port. 3.8.3.1. WIRE-INPUT It is used to set the input type when working with the device connected into WIEGAND input port. Category Explanation NONE WIEGAND input port is not used.
AY-B9250BT User Guide 3.8.3.4. SITE CODE It is used to set the value of Site Code that is sent to WIEGAND output port. 3.8.3.5. SEND INFO It is used to select the transmitting data by the output port. SEND INFO...
AY-B9250BT User Guide NETWORK The setting information related to network OPTION TNA, Screen setting, Saving, Time out, Lock mode INT DEVICE Display the setting state related to the internal device. EXT DEVICE Display the setting state related to the external device.
AY-B9250BT User Guide 3.9.5. EXT DEVICE It displays the setting information related to the external device. 3.9.6. I/O PORT It reflects the current I/O Port state and displays it on the screen. Output Port: LOCK1, LOCK2 Input Port: DM0~DM2, W0IN, W1IN, INSIDE Open, Tamper When the input port shorts GND, the signal modifies from HIGH to LOW.
AY-B9250BT User Guide 3.10. RECOVERY Menu RECOVERY has the features as follows. Category Explanation INITIALIZE CONFIG LOG DB FACTORY SELF TEST INT DEVICE EXT DEVICE BACKUP LOG EXPORT USER EXPORT USER IMPORT FW UPDATE REBOOT REBOOT 3.10.1. INITIALIZE It is used to initialize CONFIG, LOG DB, and FACTORY in the terminal.
AY-B9250BT User Guide 3.10.1.3. FACTORY INIT If trying FACTORY INIT, setting data, authentication log data, and user registration information are initialized as setting state when shipping from factory. ★ It should be careful because the current data can be lost when you setting wrong.
Page 59
AY-B9250BT User Guide When authentication successes, it repeats and play voice guidance. Card Test As you see below, the screen displays “INPUT CARD” state at first. When recognizing the card, “Success” screen displays and it returns “INPUT CARD” state again. If you want to stop testing, press F2.
Page 60
AY-B9250BT User Guide 3.10.2.2. EXT DEVICE It can test the features related to the external device by itself. Category Explanation DOORLOCK Lock1, Lock2 SENSOR IN INSIDE OPEN TAMPER DOORLOCK Test It is used to check the state of LOCK1, LOCK2 OPEN /CLOSE from the terminal.
AY-B9250BT User Guide 3.10.3. BACKUP When the saved data from the terminal sends to USB by using UDL device or brings the data from USB memory and then applies it, it is used. It is available only when the UDL module is.
AY-B9250BT User Guide 3.10.3.2. USER EXPORT The saved User DB from the terminal saves in USB memory through UDL. It saves as USER.NDB file. 3.10.3.3. USER INPUT It reads the user DB from USB memory through UDL and adds it in terminal user DB.
AY-B9250BT User Guide Appendix 1. Glossary <Glossary > Administrator (Admin) - The administrator can access the terminal menu mode. He/she has the authority to add/modify/delete terminal users and to change the operating environment by changing settings. - If there is no registered administrator in the terminal, anybody can access to the terminal menu and change settings.
AY-B9250BT User Guide Appendix 2. Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: - This device may not cause harmful interference. - This device must accept any interference received, including interference that may cause undesired operation.
AY-B9250BT User Guide Appendix 3. Radio Equipment Directive (RED) Rosslare hereby declares that the AY-H6355BT is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU.
AY-B9250BT User Guide Appendix 4. RoHS Directive Under our sole responsibility that the following labeled AY-U9xxBT is tested to conform to the Restriction of Hazardous Substances (RoHS) directive – 2011/65/EU – in electrical and electronic equipment.
Page 67
+86 755 8610 6101 Toll Free: +1-866-632-1101 support.cn@rosslaresecurity.com Local: +1-817-305-0006 India Fax: +1-817-305-0069 support.na@rosslaresecurity.com Rosslare Electronics India Pvt Ltd. Tel/Fax: +91 20 40147830 Europe Mobile: +91 9975768824 Rosslare Israel Ltd. sales.in@rosslaresecurity.com 22 Ha'Melacha St., P.O.B. 11407 Rosh HaAyin, Israel Tel:...
Need help?
Do you have a question about the AY-B9250BT and is the answer not in the manual?
Questions and answers