Meter Test Stand
Null4:
General Information
These are instructions for installing attachments and
accessories to mount and operate the Great Plains
®
Air-Pro
Meter on the MeterMax
These instructions apply to an installation of:
Kit
®
403-940A Air-Pro
Ultra Test Stand Kit
One kit provides everything needed to operate an
®
Air-Pro
meter on the MeterMax
seed disks not included.
Tools Required
• basic hand tools
Entanglement Hazard:
Keep hands, loose clothing, and hair away from all moving
parts. Unplug Test Stand when making adjustments or servic-
ing. The drive can cause serious bodily injury.
Call-Outs
to
Single-digit callouts identify components in the
1
9
currently referenced Figure. These numbers
may be reused for different items from page to
page.
to
Two-digit callouts in the range 11 to 23 refer-
11
23
ence new parts from the list on page 16.
®
a. MeterMax
is a registered trademark of Precision Planting, Inc.
© Copyright 2019
Printed 05/17/2019
®
Meter Ultra Test Stand Kit - Second Generation
®
UltraTest Stand.
Kit Description
®a
Ultra Test Stand,
Part Lists
When you see this symbol, the subsequent instructions
and warnings are serious - follow without exception.
Your life and the lives of others depend on it!
Null4:
Air-Pro
MeterMax
Part Lists
Great Plains Manufacturing, Inc.
Figure 1
®
Meter Mounted on the
®
Ultra Test Stand
1
TP-71226
403-942M

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Air-Pro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GREAT PLAINS Air-Pro

  • Page 1 - follow without exception. Your life and the lives of others depend on it! General Information These are instructions for installing attachments and accessories to mount and operate the Great Plains ® ® Air-Pro Meter on the MeterMax UltraTest Stand.
  • Page 2: Remove Existing Attachments

    ® Front Page Part Lists Air-Pro Ultra Test Stand Kit Great Plains Manufacturing, Inc. Remove Existing Attachments Refer to Figure 2 1. Remove the following six attachments from the ® MeterMax UltraTest Stand and store with unit. • Finger Meter Left Hand •...
  • Page 3 ®  in hose supplied with the Air-Pro kit. ® 7. Use the two spacers to center the Air-Pro seed tube in the seed tube bracket. 8. Position seed tube and holder in its proper location ® on the RH Air-Pro...
  • Page 4: Connect Blower Supply Hose

    ® Front Page Part Lists Air-Pro Ultra Test Stand Kit Great Plains Manufacturing, Inc. Connect Blower Supply Hose Refer to Figure 7, Figure 8, and Figure 9 ® 9. The Air-Pro meter uses the blower port found at the back of the Ultra Test Stand. Make sure you add the hose extension for a secure connection.
  • Page 5: Mount Air-Pro ® Meter

    Null4: Figure 11 TP-71233 Adaptor for Blower Hose Refer to Figure 12 ® 16. Mount the Air-Pro meter on the locating pins of the brackets installed in Figure 5 and clamp in place. Null4: Figure 12 TP-71234 ®...
  • Page 6: Display Monitor

     18. Cut seed hose in above the black molded boot. Insert the funnel and attach to top of seed in ® port of the Air-Pro meter. Refer to Figure 1 on page 1. Null4: Figure 14 31086 Funnel and Seed Hose...
  • Page 7: Meter Pressurization

    Meter Pressurization Front Page Part Lists Great Plains Manufacturing, Inc. Meter Pressurization Note: These are suggested initial (starting) pressures. Higher or lower pressure adjustments can be expected to maximize singulation. Initial Meter Pressurization: Cotton Reading a Corn Pressure Chart 1.5 inches of water (any seed density) 1.
  • Page 8 ® Front Page Part Lists Air-Pro Ultra Test Stand Kit Great Plains Manufacturing, Inc. Initial Meter Pressurization: Flat Corn Pressure/Seed Comparison Linear (Flat Corn Large) Linear (Flat Corn Small) Disks 817-836C & 817-838C Flat Corn-Large Disks 817-795C & 817-797C Flat Corn-Small...
  • Page 9: Air-Pro ® Meter Disk Selection

    ® Air-Pro Meter Disk Selection Front Page Part Lists Great Plains Manufacturing, Inc. ® Air-Pro Meter Disk Selection Front Page Part Lists 05/16/2019 403-942M...
  • Page 10 ® Front Page Part Lists Air-Pro Ultra Test Stand Kit Great Plains Manufacturing, Inc. Null4: Recommended Seed Disks (2 of 3) Front Page Part Lists 403-942M 05/16/2019...
  • Page 11 ® Air-Pro Meter Disk Selection Front Page Part Lists Great Plains Manufacturing, Inc. Recommended Seed Disks (3 of 3) Front Page Part Lists 05/16/2019 403-942M...
  • Page 12 ® Front Page Part Lists Air-Pro Ultra Test Stand Kit Great Plains Manufacturing, Inc. Front Page Part Lists 403-942M 05/16/2019...
  • Page 13: Seed Spacing

    ® Air-Pro Meter Disk Selection Front Page Part Lists Great Plains Manufacturing, Inc. Seed Spacing Seed Spacing (U.S. Customary units, page 1 of 2) Row Spacings Twin Row Single Row 20 in. 30 in. 36 in. 38 in. 40 in.
  • Page 14 ® Front Page Part Lists Air-Pro Ultra Test Stand Kit Great Plains Manufacturing, Inc. Seed Spacing (U.S. Customary units, page 2 of 2) Row Spacings Twin Row Single Row 20 in. 30 in. 36 in. 38 in. 40 in. Plant 10 in.
  • Page 15 Ezee Glide Plus Talc + Graphite Mix 821-069C bucket, 5 gallon (19 liter) Ezee Glide Plus Lubricant To maximize performance of Great Plains metering sys- tems, it is imperative to use only “Ezee Glide Plus” lubri- cant. “Ezee Glide Plus” Talc + Graphite lubricant is mandatory for all seeds, especially treated or inoculated seed.
  • Page 16 CP KENT CAT4 M QD X 1/4 HB 830-415C CP KENT CAT4 F QD X CAP 891-328C EL 45 7/16MORB X 1/4HB 990-021R HOSE 1/4 RUBBER AIR AEOD??????? Great Plains Manufacturing, Inc. Corporate Office P.O. Box 5060 Salina, Kansas 67402-5060 USA Front Page Part Lists 403-942M 05/16/2019...

Table of Contents