Download Print this page

Magnum M8-EPSM Manual

Plug-in switch module

Advertisement

Quick Links

Plug-In Switch Module
[Mx-
]
EPSM
Package Contents:
- Plug-in Switch Module
Product Description:
The Magnum Plug-In Switch Module provides an easy way to save energy and control
lighting and appliance loads based on room occupancy.
The module simply plugs into any standard wall receptacle and receives wireless signals
from Magnum compatible products that tell it when to power on or off.
Features Include:
• Provides switching of plug-in electrical loads
• Communicates with other Magnum devices to enable energy savings
• Plugs into any standard outlet, no wiring required (optional mounting plate provided)
• Easily links with wireless rocker pads or sensors or connects to simple corded accessory
rocker pad
SPECIFICATIONS
Part Numbers
M9-EPSM (902 MHz - North America)
(Frequency Dependant)
M8-EPSM (868 MHz - Europe and China)
MJ-EPSM (928 MHz - Japan)
Power Supply
120 VAC 50/60Hz
Maximum Load or Contact
General purpose: 15A@ 120VAC
Ratings
Resistive: 15A 120VAC
Motor: ½ HP @ 120VAC
Tungsten: 960W @120VAC
Ballast: 600W @ 120 VAC
Power Consumption
1.1W full load, 500mW quiescent
Transmission Range
80ft (25m)
Module Dimensions
4.09" L x 1.85" W x 1.26" D
Cord Lengths
Plug cord: 3 ft. Outlet cord: 1 ft.
Weight
12.3 oz. (348 g)
Environment
• Indoor use only
• 32° to 104°F (0° to 44°C)
• 20% to 95% relative humidity (non-condensing)
Agency Compliance
cULus, FCC, and I.C.
Magnum Innovations
5675 Hudson Industrial Pkwy, Suite 3 -
Proudly Made
In America
Tools Required:
- None
Hudson, OH 44236 -
phone 330.915.2382 - fax 330.529.5279 - www.magnum-innovations.com - info@magnum-innovations.com
Planning
Take a moment to plan and install the module for user convenience and optimal communi-
cation with other system components.
• Consider where the device will be plugged in, what it will control, and how power cords
can be kept out of the way
• Consider the construction materials in the space and obstacles that may interfere with
RF signals
Installing
Warning: ELECTRCAL SHOCK HAZARD. Do not open, cut the cord, or rewire the device.
Serious injury or death could result.
1. Turn the electrical load on (for example, a lamp) and unplug the cord from the wall
outlet.
2. Plug the cord of the electrical load, for example a lamp, into the outlet cord of the
module.
3. Plug the module into a standard wall outlet.
4. Test the connection by actuating the load using the Set button ( ) on the module.
Note: The plug and outlet are polarized, and not intended to be
mated with unpolarized devices.
Optional Mounting
The Plug-In Switch Module provides a fixed mounting option to prevent damage and theft.
Using the included mounting plate, mount the device high enough off the floor to avoid
spills and impact with cleaning equipment.
1. Using a level and a pencil, lightly mark two small dots to align the upper edge of the
module on the wall where you want to mount it.
Tip: For easy housekeeping, provide sufficient clearance for vacuum cleaners.
2. Slide the mounting plate off the back of the module.
3. With the tab lock side down, mount the plate securely to the wall.
a. Using the pencil marks to
ensure it's level, mark the
two mounting screw drill
points.
b. Drill two holes for the wall
anchors with a 3/16" drill
bit and insert the wall
anchors.
c. Insert the first screw
loosely and level the module.
d. Insert the second screw, and then hand tighten the first screw.
4. Slide the module onto the
mounting plate until it clicks in place.
Note: Any of the Magnum rocker
pads can be linked to the module.
For affordable remote control,
consider the Magnum Corded Accessory Rocker Pad (soldseparately).

Advertisement

loading

Summary of Contents for Magnum M8-EPSM

  • Page 1 Note: The plug and outlet are polarized, and not intended to be Product Description: mated with unpolarized devices. The Magnum Plug-In Switch Module provides an easy way to save energy and control lighting and appliance loads based on room occupancy. Optional Mounting The module simply plugs into any standard wall receptacle and receives wireless signals from Magnum compatible products that tell it when to power on or off.
  • Page 2 • Rocker Pad: click the top button 3 times quickly. (switching a light on or off for example). Transceivers can be linked to transmitters as well as other transceivers. A Magnum transceiver can have up to 30 devices linked to it. Device linked successfully.
  • Page 3 1. Access Basic Setup mode. 2. Select the Vacancy Check menu. 3. Select an option. 4. Save the selection. Magnum Innovations 5675 Hudson Industrial Pkwy, Suite 3 - Hudson, OH 44236 - phone 330.915.2382 - fax 330.529.5279 - www.magnum-innovations.com - info@magnum-innovations.com...
  • Page 4 (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Magnum Innovations 5675 Hudson Industrial Pkwy, Suite 3 - Hudson, OH 44236 - phone 330.915.2382 - fax 330.529.5279 - www.magnum-innovations.com - info@magnum-innovations.com...

This manual is also suitable for: