Locking Collet

Not locking shaft in place
If the locking collet fails to lock the rod/shaft in place with 35 ft-lb (47 .45 Nm) of torque applied to the collet locking
bolt, the locking collet is damaged and must be replaced . Please contact the factory to order a replacement .
Do not interchange collets between tool holders . Collets are specially machined for each tool holder individually and cannot
be interchanged . Collet repair must be performed by the factory .
Rod/shaft marred by collet
1. Check collet orientation . If the collet has an orientation indicator dot (see photo), the
indicator dot must always face toward the top of the holder . Collets without the indicator
dot are not dependent on orientation .
a. If the collet is upside down, remove the locking collet bolt from the holder and gently
tap the holder on a hard surface to remove the collet .
b. Reinstall the collet with the orientation indicator dot facing toward the top of the
holder, and then reinstall the locking collet bolt .
2. Check the collet for wear .
– A worn collet will not distribute pressure evenly on the rod/shaft and may cause
damage .
– If the collet is worn, the entire holder must be replaced immediately . Collets are matched to a body assembly
during manufacturing and cannot be replaced separately .

Standard Warranty

Sentry Equipment Corp ("Seller") warrants products manufactured by it and supplied hereunder ("Products") to be free
from defects in workmanship and, to the extent materials are selected by Seller, to be free from defects in materials, in
each case for a period as defi ned in the table below:
Product Line
Sentry®
Waters Equipment
To view the full warranty, go to www .sentry-equip .com/warranty .
12
Product Category
1 . Automatic Sampling
2 . Corrosion Monitoring
3 . Manual Sampling
4 . Sample Conditioning
5 . Sampling & Analysis Systems
6 . Replacement Parts (without expiration dates)
1 . Sampling & Analysis Systems
2 . Replacement Parts (without expiration dates)
Warranty Period
Eighteen months from date of shipment
or twelve months from startup, whichever
occurs fi rst
Twelve months from date of shipment
Sentry Equipment Corp