Z-Wave IR Extender PAR01
PAR01, is a Z-Wave plus compliant Z-Wave-to-IR Bridge to control split
air conditioner by receiving Z-Wave command and translating to
Infrared command. With its comprehensive built-In and cloud-stored IR
database (library). PAR01 can control different
brands and models of air conditioners worldwide.
PAR01 is a security enabled Z-Wave plus device. A security Enabled
Z-Wave Plus Controller must be used in order to fully utilize the
product.
PAR01 is a Z-Wave slave device, it depends on gateway to setup
particular AC brand with correct IR code. Different gateway has
different user interface for setup.
This product can be included and operated in any Z-Wave
TM
with other Z-Wave
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
The device adopts the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
TM
500 series chip, when your Z-Wave
TM
500 series devices. The
Adding to Z-Wave
In the first time, activate the device through battery, then it can be
added into the Z-Wave
controller is in the add mode. And then power on the device. The
device will auto start the NWI (Network Wide Inclusion) mode. And it
should be added in 5 seconds. You will see the LED light ON one
second.
Function
Add
Remove
TM
network
Reset??
TM
TM
Network
TM
network.
First, make sure the primary
Description
TM
1. Have Z-Wave
Controller entered add mode.
2. Press the add key in the casing three times
3. After add successful, the device will wake to
receive the setting command from Z-Wave
Controller about 20 seconds.
TM
1. Have Z-Wave
Controller entered remove mode.
2. Press the add key in the casing three times
3. Hold down the central key, then press the top-right
key three times within 1.5 seconds to enter the
remove mode.Node ID has been excluded.
Notice: Use this procedure only in the event that
the primary controller is lost or otherwise
inoperable.
1. Hold down the central key, then press the top-right
key four times within 1.5 seconds and do not
release the top-right key in the 4
LED will light ON.
Note: PSR03-C is reset by pressing panic key four
times within 1.5 seconds and do not release the top-
th
right key in the 4
pressed.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the keys. If successful,
the LED will light ON one second. Otherwise, the
TM
th
pressed, and the
Need help?
Do you have a question about the PAR01 and is the answer not in the manual?
Questions and answers