Recover ID ....................41 Delete ID ....................42 Setting Anti-passback ................43 Setting Anti-passback For Individual Addresses ........44 Setting Anti-passback For Multiple Addresses ........45 Auto Open Zone Settings ................ 46 Open Time Zone Settings ................ 47 RSSD AR-727H MANUAL...
Page 3
Changing Language ................62 Time & Attendance Settings ..............63 Setting Serial Port Output ............... 64 Setting RS232 Printer Output ..............65 Resetting Master Code ................66 Upgrading Firmware ................67 Specifications ..................68 Table Of Users ..................69 RSSD AR-727H MANUAL...
The AR 727H Controller 727H Controller 727H Controller The AR-727H is a versatile single door proximity controller that can be used as stand-alone or networked. Key Features: Built-in Proximity reader 1,024 User card capacity, 65,536 User card capacity in stand-alone mode...
Arming Output (Active Low) BA Data Input (W0) Buzzer Output 5V 100mA, Low Buzzer Pink Card Present Output Active Low Brown/White Card Present Green LED Output 5V 20mA, Max Brown (Transistor Output) Yellow Red LED Output 5V 20mA, Max RSSD AR-727H MANUAL...
- Navigates down the menu. In Time & Attendance mode, press once for Overtime Off, press twice for Return. - Press to escape current menu screen. - Press to enter data. - Press together to lock/unlock Keypad. & RSSD AR-727H MANUAL...
Before attempting a Factory Reset make a record programming will be lost. Before attempting a Factory Reset make a record of all necessary programming. of all necessary programming. of all necessary programming. of all necessary programming. RSSD AR-727H MANUAL...
BROWN BROWN OUTPUT OUTPUT YELLOW YELLOW BROWN BROWN OUTPUT OUTPUT SHORT TO GND OPEN WG34 OPEN OPEN WG26 SHORT TO OPEN GROUND NOTICE NOTICE NOTICE NOTICE WG Mode will only change after powering off and on again. RSSD AR-727H MANUAL...
Page 9
737U Reader Token DIP Switch Settings 737U Reader Token DIP Switch Settings 737U Reader Token DIP Switch Settings Soyal Standard TOKENS TOKENS TOKENS TOKENS Soyal Standard NOTICE NOTICE NOTICE NOTICE WG Mode will only change after powering off and on again. RSSD AR-727H MANUAL...
AR- - - - 727HBR1121 WITH AR 727HBR1121 WITH AR- - - - 737HB 737HB- - - - RAY 727HBR1121 WITH AR 727HBR1121 WITH AR 737HB 737HB RSSD AR-727H MANUAL...
Page 11
737HB- - - - RAY FOR READ IN RAY FOR READ IN- - - - READ OUT READ OUT 727HBR1121 WITH 2 727HBR1121 WITH 2 X AR X AR 737HB 737HB RAY FOR READ IN RAY FOR READ IN READ OUT READ OUT RSSD AR-727H MANUAL...
Page 12
AR- - - - 727HBR1121 WITH AR 727HBR1121 WITH AR- - - - 721U 721U 727HBR1121 WITH AR 727HBR1121 WITH AR 721U 721U RSSD AR-727H MANUAL...
Page 13
AR- - - - 727HBR1121 WITH AR 727HBR1121 WITH AR- - - - 727HU 727HU 727HBR1121 WITH AR 727HBR1121 WITH AR 727HU 727HU RSSD AR-727H MANUAL...
Page 14
AR- - - - 727HBR1121 WITH AR 727HBR1121 WITH AR- - - - 661U 661U 727HBR1121 WITH AR 727HBR1121 WITH AR 661U 661U RSSD AR-727H MANUAL...
Page 15
AR- - - - 727HBR1121 WITH S 727HBR1121 WITH S 727HBR1121 WITH SINGLE AND MULTI FLOOR LIFT CONTROL 727HBR1121 WITH S INGLE AND MULTI FLOOR LIFT CONTROL INGLE AND MULTI FLOOR LIFT CONTROL INGLE AND MULTI FLOOR LIFT CONTROL RSSD AR-727H MANUAL...
Page 16
AR- - - - 727HBR1121 WITH O 727HBR1121 WITH O 727HBR1121 WITH O 727HBR1121 WITH OPTIONAL LOCK CONNECTIONS PTIONAL LOCK CONNECTIONS PTIONAL LOCK CONNECTIONS PTIONAL LOCK CONNECTIONS RSSD AR-727H MANUAL...
Page 17
AR- - - - 727HBR1121 WITH A 727HBR1121 WITH A 727HBR1121 WITH A 727HBR1121 WITH ALARM SOUNDER AND DOOR CONTACTS LARM SOUNDER AND DOOR CONTACTS LARM SOUNDER AND DOOR CONTACTS LARM SOUNDER AND DOOR CONTACTS RSSD AR-727H MANUAL...
Page 18
AR- - - - 727HBR1121 WITH PC INTERFACE CONNECTI 727HBR1121 WITH PC INTERFACE CONNECTI 727HBR1121 WITH PC INTERFACE CONNECTIONS 727HBR1121 WITH PC INTERFACE CONNECTI RSSD AR-727H MANUAL...
Page 19
AR- - - - 727HBR1121 NETWOR 727HBR1121 NETWORKING CONNECTIONS KING CONNECTIONS 727HBR1121 NETWOR 727HBR1121 NETWOR KING CONNECTIONS KING CONNECTIONS RSSD AR-727H MANUAL...
Page 20
AR- - - - 727HBR1121 NETWOR 727HBR1121 NETWORKING CONNECTIONS WITH RS KING CONNECTIONS WITH RS- - - - 485 REPEATER 485 REPEATER 727HBR1121 NETWOR 727HBR1121 NETWOR KING CONNECTIONS WITH RS KING CONNECTIONS WITH RS 485 REPEATER 485 REPEATER RSSD AR-727H MANUAL...
Page 21
AR- - - - 727HBR1121 NETWOR 727HBR1121 NETWOR 727HBR1121 NETWOR 727HBR1121 NETWORKING CONNECTIONS WITH AR KING CONNECTIONS WITH AR KING CONNECTIONS WITH AR KING CONNECTIONS WITH AR- - - - 716E 716E 716E 716E RSSD AR-727H MANUAL...
Code is lost, the only way to reset the Master Code is by connecting the unit Code is lost, the only way to reset the Master Code is by connecting the unit Code is lost, the only way to reset the Master Code is by connecting the unit RSSD AR-727H MANUAL...
Networking is for Modes 4 and 8 and is specifically for networking either directly to a PC or under a 716E. NOTICE NOTICE NOTICE NOTICE When changing Control Mode from Mode 6 to Mode 4 and vice versa, it is necessary to delete all User Card Data first RSSD AR-727H MANUAL...
Page 25
Enter Number for required Tag Format. Succeeded ! The Display will now show NOTICE NOTICE NOTICE NOTICE When changing Control Mode from Mode 6 to Mode 4 and vice versa, it is necessary to delete all User Card Data first RSSD AR-727H MANUAL...
Input Date & Time YyMmDdHhMmSs Enter the time and date The Display will show:- Month/Day Format 1: DD/MM 2: MM/DD Current Data: Enter the required number for month/day format and press The Display will now show Succeeded ! RSSD AR-727H MANUAL...
When Latch Mode has been set, the lock relay will switch and the door will latch open after a valid programmed token has been presented. The door will then stay open until a valid programmed token is presented and then the relay will switch back and the door will lock. RSSD AR-727H MANUAL...
Use F1 or F2 to scroll to 2. Egress (R.T.E) and press Request To Exit The Display will show:- 1: YES 2:NO Data: Enter number required. Entering will enable Exit function, entering will disable Exit Function. The Display will now show Succeeded ! RSSD AR-727H MANUAL...
This is the Door number. For all the doors to show different numbers in the software, this must be different for each door. This is usually the same as Door Num: H above. The Display will show Succeeded! RSSD AR-727H MANUAL...
Memory Locations until a suitable number of empty slots is found. When a Memory Location contains a programmed token, the token number is shown on the bottom line of the screen:- User Address : F3: Prev F4: Next Memory (0-01023): 00000 Location Token 05121:73478 Number RSSD AR-727H MANUAL...
The Display will show:- User Address : F3: Prev F4: Next (0-01023):00000 00000 Enter the User Address, for this example and press (User Address is the memory slot into which the token will be entered) Continued Over RSSD AR-727H MANUAL...
Page 32
The Display will briefly show:- Set ***** Code: 00012:62362 Scan Data: XXXX **** Scan Data: XXXX will quickly scroll through 00001 to 65535 The Display will now show:- Completed! Address: 00000 ID: 00012:62362 The Token has been programmed successfully. RSSD AR-727H MANUAL...
Into RF Area Present the token with the lowest Card Code number to the bottom of the controller. The Display will now show:- Close Tag Into RF Area 00001 - 00010 OK ! All Tokens have been successfully programmed. RSSD AR-727H MANUAL...
The Display will now show:- Close Tag Into RF Area 00001 - 00001 OK ! Present the rest of the tokens one at a time, and when finished press until the display shows and then press 6. Quit RSSD AR-727H MANUAL...
The Display will now show:- Close Tag Into RF Area Present the token to the bottom of the controller. The Display will now show:- Close Tag Into RF Area 00001 - 00001 OK ! The Token has been programmed successfully. RSSD AR-727H MANUAL...
Token and PIN number 4: Pause Suspend token The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE When Networking, the above programming is not required. Please refer to the 701 Client Software manual for Access Mode settings in networking mode. RSSD AR-727H MANUAL...
E.g. To suspend 25 addresses starting with address 00012:- Input Start Address (0-01023): 00000 Enter 00012 and press The Display will now show:- Input End Address (˜-01023): 00012 Enter and press 00036 The Display will now show Succeeded! RSSD AR-727H MANUAL...
E.g. To recover 25 addresses starting with address 00012:- Input Start Address (0-01023): 00000 Enter 00012 and press The Display will now show:- Input End Address (˜-01023): 00012 Enter and press 00036 The Display will now show Succeeded! RSSD AR-727H MANUAL...
E.g. To delete 25 addresses starting with address 00012:- Input Start Address (0-01023): 00000 Enter 00012 and press The Display will now show:- Input End Address (˜-01023): 00012 Enter and press 00036 The Display will now show Succeeded! RSSD AR-727H MANUAL...
The Display will now show:- Code: 00012:xxxxx (1-65535) 62362 Enter the SECOND five digit number on the bottom line of the token Using the above example, type in 62362 The Display will now show Succeeded! RSSD AR-727H MANUAL...
00012 The Display will now show:- Code: 00012:xxxxx (1-65535) 62362 Enter the SECOND five digit number on the bottom line of the token Using the above example, type in 62362 The Display will now show Succeeded! RSSD AR-727H MANUAL...
The Display will now show:- Code: 00012:xxxxx (1-65535) 62362 Enter the SECOND five digit number on the bottom line of the token Using the above example, type in 62362 The Display will now show Succeeded! RSSD AR-727H MANUAL...
The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE This only enables Anti-passback. Refer to the next two pages for full programming. RSSD AR-727H MANUAL...
Enter Number required. The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE For Anti-passback to function properly it needs to be enabled following the programming on the previous page of this manual. User Address = Memory Slot RSSD AR-727H MANUAL...
1: Yes 2: No Data : Enter the number required. The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE For Anti-passback to function properly it needs to be enabled following the programming on page 51 of this manual. RSSD AR-727H MANUAL...
Auto Open Zone 1:Yes 2:No Data: Enter number required. The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE This function only enables Auto Open Zone. Refer to the next page, Open Time Zone Settings for full programming parameters. RSSD AR-727H MANUAL...
Auto Open Zone Settings for details on enabling this function. For Firmware Version 7V6 Onwards, there are a total of 10 time zones. If any more than 1 time zone is required, follow the steps above for programming all desired time zones. RSSD AR-727H MANUAL...
Single Floor Range: 1 32 Enter floor number required. The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE This function only programs access to single floors. For multi floor access, refer to the following page of this manual. RSSD AR-727H MANUAL...
1 0 1 0 0 0 1 0 1 0 0 0 1 1 1 1 The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE For multi floor access, the AR-401-R016B needs to be set up. The following page shows DIP switch and jumpers settings needed for this function. RSSD AR-727H MANUAL...
The Display will show: - Quit from programming and test time is as required. **Please note: The time set using the above procedure will be the time for all 16 relay outputs on the AR-401R16 interface pcb. RSSD AR-727H MANUAL...
With the Switch set to N.C. and the Jumpers set to NO, the Relays are closed going open. With the Switch set to N.O. and the Jumpers set to NC, the Relays are closed going open. With the Switch set to N.O. and the Jumpers set to NO, the Relays are open going closed. RSSD AR-727H MANUAL...
Press (#) On Bell 1:Yes 2:No Data: Enter Number required. The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE When this function is enabled it uses the Alarm Output, which cannot be used for any other purpose. RSSD AR-727H MANUAL...
If this function is enabled, as soon as the door is closed, regardless of how much lock activation time is left, the door will lock. The Display will show Succeeded! RSSD AR-727H MANUAL...
Door Close Time is the amount of time the door can be held open before activating the alarm output. The door has to have normally closed door contacts fitted for this function to work. Succeeded ! The Display will now show RSSD AR-727H MANUAL...
Enter the time required in seconds and then press E.g. Entering will give an alarm relay time of 10 seconds. This function controls how long the Alarm will be activated arter an alarm event trigger. The Display will now show Succeeded ! RSSD AR-727H MANUAL...
Enter the time required in seconds and then press E.g. Entering will give an Alarm Delay Time of 10 seconds. Alarm Delay Time is the amount of time between an alarm event trigger and the alarm activating. The Display will now show Succeeded ! RSSD AR-727H MANUAL...
The Display will show:- Input 4 Digit No Range: 0001 9999 Data: 1234 Enter the desired password and then press This function programs the Password for setting the Alarm. The Display will now show Succeeded ! RSSD AR-727H MANUAL...
The Display will show:- Input : (0 2500) Current (ms): 1000 Enter the time required in seconds and then press E.g. Entering will give an Alarm Pulse of 0.1 seconds. 0100 The Display will now show Succeeded ! RSSD AR-727H MANUAL...
This function cuts short the alarm time. Door contact s need to be fitted for this function to operate properly. If the alarm goes off, it is stopped by the door closing. The Display will show Succeeded! RSSD AR-727H MANUAL...
The Display will show:- Force Open Alarm 1:Yes 2:No Data: Enter number required. This function will enable the Alarm to activate if the door is opened without using a valid token or egress button. The Display will show Succeeded! RSSD AR-727H MANUAL...
The Display will show Succeeded! NOTICE NOTICE NOTICE NOTICE For this function to work properly, the Serial Port needs to be enabled for Duress Code. For further details refer to Setting Serial Port Output on page 71 of this manual. RSSD AR-727H MANUAL...
NOTICE NOTICE If the language setting is changed by mistake the easiest way to change it back to English is to enter the following: Enter Programming Mode *123456# *MASTER CODE# Enter The display will show Succeeded ! RSSD AR-727H MANUAL...
Break RTN. In Time & Attendance mode, press once for Overtime On, F3..press twice for Go. In Time & Attendance mode, press once for Overtime Off, F4..press twice for Return. RSSD AR-727H MANUAL...
For further details on the Duress Alarm features refer to the Duress Code For further details on the Duress Alarm features refer to the Duress Code Settings section on page 68. Settings section on page 68. Settings section on page 68. Settings section on page 68. RSSD AR-727H MANUAL...
DB25 Male Black (8th Pin of CN3) Pin GND SH24 Suggested Circuit Printer Pin RX (in Serial Port Yellow/White (2nd Pin of CN2) MAX232A Alternative Circuit (Distance between AR-727H & SH24 Printer < 1M C1815 TP1 DATA RSSD AR-727H MANUAL...
Open ISP Tools and select AR727,747H from the list on the left hand side, then select the relevant COM Port and Node Number of the controller. Click on the Reset Master Code button and the master code will be reset to *123456#. RSSD AR-727H MANUAL...
WILL This type of interruption stop the controller from functioning and the processor will need to be replaced for the system to function correctly. RSSD AR-727H MANUAL...
TABLE OF USERS TABLE OF USERS TABLE OF USERS TABLE OF USERS ____________________________________________________________________ Name of On-Site Programmer(s): ____________________________________________________________________________ Installation Company: ____________________________ Tel: DEFAULT MASTER CODE:- *123456# __________________________ Date: ______________________ Lock Time: USER MASTER CODE: ______________________ Lock Type: User Address User Address User Address User Address Users Name...