Do you have a question about the IPU-1025 and is the answer not in the manual?
Questions and answers
Summary of Contents for Ude IPU-1025
Page 1
IPU-1025 Audio over IP AUDIO IP DECODER with 25W Class D AMPLIFIER Installation - Configuration - Use 179,5 FRONT IPU-1025 DEVICE CALL FAULT CONFIG NET 45,0 ACTIVITY Engineered and made in E.U. SIDE 135,2 INPUT IPU-1025 MADE IN SPAIN AUDIO LINK...
Webserver using a password, but if the user or operator needs to monitor the status of it, then also can be done remotely, just knowing the IP address of the device. Installation - Configuration - Use - IPU-1025 Rev. 1...
32W máx. at 24Vdc. (IPU-100P mode: 38W) Operation temperature -5 a +45ºC (0 a +40ºC, recommended) Storage temperature -15 a +60ºC Humidity 5% a 95%, witthout condensation Weight 0.6 Kg Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
Page 4
Figure 1 provides an example configuration of the PA system for IP networks of UDE. The audio decoder IPU-1025 model is the element that allows the decoding of audio sent digitally to a conventional audio signal to be amplified conveniently and connected directly to speakers, horns or trumpets.
. This indicator is activated when the IPU-1025 device is the generator of a voice call, there are two types of call: Using a IP Paging Desk Controller (IPU-100P) connected to the IPU-1025 reports that the user is performing an outgoing call to one or more areas.
Page 6
IPU-360 server. The IPU-1025 automatically executes a registration attempt to the server configured in its settings and every time you restore the power will also run the connection attempt. During the process, the device remains without registration with the IPU-360 server, the DEVICE FAULT LED is RED, indicating that there is a connection problem with the server so the device is not operating temporarily.
DC IN. This connector allows us to power the device using a 24Vdc external power supply ( model: IPW-25). These include that of the 2 powering methods available on the IPU-1025, the power input with the IPW-25 AC adapter (DC IN), is the highest priority input and disables the battery backup input, which only supply power if the voltage delivered in the DC IN terminal is absent or is lower than 18Vdc.
5. DEVICE CONFIGURATION (WEBSERVER). The IPU-1025 configuration is done by accessing to the IP address assigned to the device by the site administrator if you work in Manual mode assignment (Static Mode), or by the DHCP server if you work in automatic mode.
Page 9
Sensor level status. It shows the voltage measurement of the sensors included on the device: 24V Adaptor, 24V Backup Battery, VOX signal level detected, Microphone supply. Area 5: Time and Date. Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
The signaling communication with the server is SIP. Furthermore due to the public address characteristics, the codifiers and decoders requires additional information inside the standardized datagram. Choose ON to use the UDE PAsignaling information. In case of priority or IPU-100P installations, the box must stay in ON option. In case of 100% SIP standard compliance OFF option.
Page 11
05004 Device extension (username) (from 4 to 8 numbers): It is the IPU-1025 SIP identifier for registering to the IPU-360 (SIP server) to be identified as unique equipment in the SIP net, of the public address by IP protocol. In the systems with UDE Audio equipments, the extensions must be contained in a specific rank:...
Page 12
SIP Streaming Priority Level (Max:01...min:99): f the UDE PA system is active and the IPU-1025 in codifier mode, a priority can be applied and the IPU-360 will manage. This priority should be between 01 (max priority) in consequence will cut other emitters and 99 (lowest priority).
Page 13
5.3 EXTENSION SIP CONFIGURATION (ONLY IPU-100P mode). The public address zone configuration with an IPU-100P desk control must be done with a IPU-1025 codifier. It is not possible to make the desk control configuration with the touch screen. The extension web server of the IPU-1025 menu will allow erasing all IPU-100P zone buttons or editing the PAbuttons of the IPU-100P desk control.
Page 14
Zone extension Main room Exit Description label Description label To edit the IPU-100P zones, exists 2 ways: 1. Erasing the whole desk control memory. 2. Editing zones keeping the zones configuration. Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
18.12 IPU-1025P Zone edit page When the erase process has finished, the webpage will be redirected to the zone edit webpage, also the touch screen of the IPU-100P will work. Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
The zone edit page has two main areas, one is the general navigation and edition of the buttons that already exist in the desk control (IPU-100P) and another area allows editing one specific button, adding the label and the different extensions that will call. IPU-1025P Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
” the new number appears in the extension Validate When all extensions, labels and buttons are ready, click on “ Send data ”. This action must be done every time one button is edited. Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
Page 18
“Send data”. ZONE EDIT PAGE IPU-1025P Without any data inside the system, the webpage should look like: - Edition of button 1. - First extension to configure inside the button 1. Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
Page 19
In button number one has only one extension to call (1001), there is no other extension to configure and configuration must be uploaded. Click on button: Send data. Button 1 configuration has been saved and screen shows the new button. 00.00 IPU-100P Paging Desk 1001 Zona 1 Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
Page 20
In button number two has only two extensions to call (1002, 1400), there is no other extension to configure and configuration must be uploaded. Click on button: Send data. Button 2 configuration has been saved and screen shows the new button. 00.00 IPU-100P Paging Desk 1001 #002 Zone 1 Main room Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
Page 21
Click on button: Send data. Button 3 configuration has been saved and screen shows the new button. 00.00 IPU-100P Paging Desk 1001 #002 #003 Zone 1 Main room Yard Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
Page 22
The IPU-1025 behaves as audio reception point and is ready to receive calls ONLY. This option is set by Factory default. AMPLIFIER (Receiver). The IPU-1025 behaves as audio reception point, allowing you to receive IP calls, with the difference that when it receive no IP calls, then IPU-1025 will amplify the audio signal present at the INPUT connector (MIC/LINE).
Page 23
+0dB (mín.) +15dB (max.) Output Bass (Cut-off Frequency): Filter cut-off frequency for supplement low frequency response. Example: 20Hz (mín.) 150Hz (max.) Options ONLY VALID when SPEAKER (Recever) mode is active. Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
(max.) DESK.MIC IN Volume (format: XXX): Select between 070 and 127, the gain level to be applied to audio from the desk control IPU-100P connected to the IPU-1025. This configuration parameter can only be used in IPU-100P mode. Always use a 3-digit format.
Page 25
Host Name (Max: 15 Characters Defines the name of our IPU-1025 within the group of interconnected devices to differentiate it from the rest in a character format. Follow NETBIOS format that enable us to access your device from a web browser without knowing its physical IP address, user being easier to remember since you can assign a name representative of the function or area where it is being serviced.
Page 26
Save NETWORK: For the changes to be validated must be pressed the button "Save Network" . As these changes modify the essential connection parameters, IPU-1025 must be reset and that is why the "Reboot In Progress" screen is displayed temporary. IPU-1025...
Enter the day, month and year desired, considering always use 2 digits format. Click on "Save DATE" to update the system calendar. IPU-1025 Always use the format: (dd/mm/yy) Example: Day (dd): 20 Month (mm): 01 Year (yy): 13 Installation - Configuration - Use - IPU-1025 Rev. 1 610.440A...
The new password will take effect only if the old password has been entered correctly and has not been wrong to confirm the new password. The system will reset to the new password take effect. Installation - Configuration - Use - IPU-1025 Rev. 1...
Caution! The erasing process is irreversible; in case of error the memory information cannot be recovered. 5.10 REMOTE REBOOT (Reboot) The IPU-1025 can be remote rebooted just click to the Reboot icon on the left menu and confirm clicking on REBOOT! icon.
Need help?
Do you have a question about the IPU-1025 and is the answer not in the manual?
Questions and answers