Refrigerant Flow Diagrams - LG LS180HSV5 Engineering Manual

Single-zone high efficiency wall mount
Hide thumbs Also See for LS180HSV5:
Table of Contents

Advertisement

REFRIGERANT FLOW DIAGRAMS

Refrigerant Flow Diagram for LSN / LSU090, 120HSV5
Indoor Unit
Th2
Th1
Heat
Exchanger
(Evaporator)
Th3
Th4
Th5
Table 8: Single Zone High Efficiency Wall Mount LSN/LSU090-120HSV5 Thermistor Details.
Thermistor
TH1
Indoor air temperature thermistor
TH2
Evaporator inlet temperature thermistor
TH3
Evaporator middle temperature thermistor
TH4
Evaporator outlet temperature thermistor
TH5
Water level sensor (optional)
TH6
Outdoor air temperature thermistor
TH7
Condensing temperature thermistor
TH8
Discharge pipe temperature thermistor
22 | PRODUCT DATA
Field Pipin g
(Copper Tubing)
Liquid Side
Ø1/4 Inches
M
Field Pipin g
(Copper Tubing)
Vapor Side
Ø3/8 Inches
Description
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Outdoor Unit
2-Way Valve
EEV
3-Way Valve
Th8
Compressor
PCB Connector
CN-TH1 (Indoor)
CN-TH3 (Indoor)
CN-TH2 (Indoor)
C_PIPE/AIR (Outdoor)
D_PIPE (Outdoor)
Th6
Heat
M
Exchanger
(Condenser)
Reversing
Th7
Valve
: Cooling
: Heating

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls090hsv5Ls120hsv5

Table of Contents