Page 1
Control Module Inc., EVSE LLC EVSE Gateway Module Model 3727 Family User Manual and Installation Guide Model 3727 Family EVSE Gateway Module Patents Pending 3727-UG-200 November 2017...
Historical Events ................................... 22 Charge History ....................................22 App Versions ....................................23 Connecting to a Network Management System ........................23 System Configuration ................................25 User Manual Page 1 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
Page 3
State of the Art EVSE Moving, Transporting and Storage ............................26 Customer Support:..................................27 Warranty ...................................... 28 User Manual Page 2 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
As part of a total EVSE network, the Watt Point Gateway Module and Charging Station should be inspected by a qualified installer prior to the initial use. Under no circumstances will compliance with the information in this manual relieve the user of responsibility to comply with all applicable codes or safety standards.
Control Module Inc., EVSE LLC. Watt Point is a U.S. registered trademark and service mark of Control Module Inc., EVSE LLC. All other products or services mentioned have the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Use this product if the enclosure is broken, cracked, open or shows any other indication of damage. Attempt to repair or service the unit yourself. SAVE THESE INSTRUCTIONS User Manual Page 5 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
NE PAS: - N'utilisez pas que ce produit si l'enceinte est cassée, fissuré, ouvrir ou afficher toute autre indication de dommages. N'essayez pas de réparer ou d'un service de l'unité de vous-même ENREGISTREZ CES INSTRUCTIONS User Manual Page 6 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
120 VAC, electrical plug. If mounted to a pole with EVSE chargers, units get their 24VDC operating voltage from the charger. The associated electrical receptacle must be mounted in a weatherproof, in use enclosure, as well, for the system to be truly weatherproof for outdoor installations.
4 in (w) x 17.48 in (h) x 1.34 in (D) *Observe all required Lockout/Tagout procedures while making any electrical connections or servicing the unit. User Manual Page 8 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
Page 10
Includes standard wall frame and 24 VDC power supply (for ZigBee com) Wall with 1-2 Mux (includes Gateway, wall frame, mux, 1-2 EVSE, serial) Wall with 1-4 Mux (includes Gateway, standard wall frame, mux, 1-4 EVSE, serial) Wall with 5-8 Mux (includes Gateway, standard wall frame, mux, 5-8 EVSE, serial) Wall...
50 pounds. The lockout approach shall be used unless the utilization of a tagout procedure will provide full personnel protection. User Manual Page 10 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
The Gateway Module is easily mounted to the wall or a pole. See the 3725 series of Installation Sheets for more information. Back of Gateway Figure 1 User Manual Page 11 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
An internal view of the 3727 Gateway Module wiring. Figure 2 is a cellular ZigBee version, Figure 2A is serial Zigbee and Figure 2B is serial only. Figure 2 Ethernet Figure 2A Ethernet Figure 2B User Manual Page 12 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
- Data Retry: The Network, Signal and Active LEDs blink every 3 seconds. - OTASP: The Network, Signal and Active LEDs blink, one at a time, in order. User Manual Page 13 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
State of the Art EVSE Indicator Lights - Server LEDs These lights reflect communication between the Gateway and the OCPP Server, and the Gateway and EVSE. The lights blink slow during communication to indicate: RXD = Signals received – on for approximately one minute when a message is received ...
The Gateway Module hosts a web browser-based application that allows you to manage the EVSE network and configure various options associated with each EVSE. In addition, it allows you to view current status and historical information that has been accumulated from each EVSE, and configure the Gateway Module’s own system.
5. Click Save Changes. The system automatically resets the gateway. This will take a few minutes. 6. From your network’s browser, enter into the URL and log back into the Module. http://[IP address]:8080/Gateway/evse User Manual Page 16 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
2. Turn on the first EVSE. This is usually the EVSE closest to the Gateway Module. 3. Slide that EVSE’s Data Router Dip Switch number 3 to Closed to put it into ZigBee Setup Mode (Figure 5). After a few moments, all the lights on the Data Router will begin flashing, letting you know the EVSE is now in ZigBee Setup Mode.
9. Slide that EVSE’s Dip Switch 3 to the Open position. After a few moments, its Data Router will first show all lights on with no flashing, and then just the blue Power light will remain on. Replace that EVSE’s cover.
Replacing a ZigBee Mesh Gateway Module In the event that you need to replace a Gateway Module, install it as discussed in the 3727 series of Installation Sheets. After installation, perform the following steps to synch it back up with the existing ZigBee Mesh Network of EVSEs. It is assumed you have logged into the browser.
EVSE. Changing EVSE Assigned Numbers (Serial Connection) 1. From the main screen, expand your list of EVSEs from the EVSE Station dropdown list and click the EVSE number you want to change. The following screen displays: 2.
State of the Art EVSE Viewing EVSE Status and Messages Once you have successfully logged in you will be brought to the EVSE status screen, which provides a list of all EVSEs in the system, as well as their current status.
The historical events view allows users to display a list of the events that were received by the Gateway Module from each EVSE or a specified EVSE for the specified date range. Once a list of events is retrieved, specific events can be located by using the free-form text filter.
5. Click the Enable Client Application checkbox. 6. Click Save. 7. You must now reset the Gateway Module. Click File and select Open Sys Config from the dropdown list. User Manual Page 23 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
Page 25
9. Click Reset Gateway. The Gateway Module resumes operation in approximately 30 seconds. Note: You will not be able to log back into the Gateway Module’s Web Browser page for approximately five minutes. User Manual Page 24 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
SetPANID button – configures the USB ZigBee radio to use the preset PAN ID (used if replacing the USB ZigBee radio) Query ZigBees button – sends a query to all EVSE radios to retrieve system status Test ZiBee – Queries ZigBee to make sure communication is working properly ...
Page 27
Bag all attaching hardware and secure on/in the unit. Store the unit in a dry, low humidity area. Protect the unit using appropriate packaging. User Manual Page 26 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
Page 28
Support at 1-888-753-8222 between the hours of 8:30 am to 5:00 pm EST, Monday to Friday. Letter Service Department Attn: Jack Batalha, Director Product Support Control Module Inc. 89 Phoenix Avenue Enfield, CT 06082 1-860-741-6064 e-mail jbatalha@controlmod.com User Manual Page 27 Model 3727-A02XX EVSE Gateway Copyright EVSE LLC 2017. All rights reserved. Patents pending.
Page 29
After receiving Customer’s notice of an Equipment defect, the EVSE LLC Service Center will provide Customer with a Return Material Authorization (RMA) number to be used by both Customer and CMI EVSE LLC to track the defective unit(s) during the return to depot repair process.