Website: www.strandlighting.com The material in this manual is for information purposes only and is subject to change without notice. Strand Lighting assumes no responsibility for any errors or omissions which may appear in this manual. For comments and suggestions regarding corrections and/or updates to this manual, please contact your nearest Strand Lighting office.
CD80/CD80AE Processor Retrofit Kit Installation Guide IMPORTANT SAFEGUARDS Safeguards When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not use outdoors. c. Do not mount near gas or electric heaters.
CD80 and CD80AE Dimming Racks. These processors represent premium performance and high value for all levels of users. Designed to interface directly with Strand Lighting’s ShowNet Ethernet, the processors include an Ethernet port. An available Ethernet switch option may be added to any processor to simplify network wiring for multiple rack installations.
Retrofit Fan Assembly Figure 1: CD80/CD80AE Processor Retrofit Kit Included Items CD80/CD80AE Processor Retrofit Kit (with C21 Processors - 120V Markets) The following items are included with the 76698-0004 CD80/CD80AE Processor Retrofit Kit: 1 Each CD80/CD80AE Retrofit C21 Processor Unit...
CD80/CD80AE Processor Retrofit Kit Installation Guide INSTALLATION Note: The procedures described in this section are the same for all versions of the CD80/CD80AE Processor Retrofit 1. Original CD80/CD80AE Processor and Fan Assembly Removal To remove the current (old-style) CD80/CD80AE processor: Step 1.
Page 8
CD80/CD80AE Processor Retrofit Kit Installation Guide Step 3. If there is sufficient clearance, connect fan power connector and mount the fan assembly as shown in Figure Existing CD80/CD80AE Dimming Rack Retrofit Fan Assembly Note: Some components not shown for clarity.
Page 9
Step 8. If applicable...if a DMX input cable was connected to original interconnection board (in upper left side of CD80/CD80AE dimming rack), move this cable to rear of retrofit kit processor housing. As illustrated in Figure 5, connect DMX input cable to either Mux A or Mux B five pin connector.
Page 10
CD80/CD80AE Processor Retrofit Kit Installation Guide Step 9. After all connections are made, install retrofit kit processor directly above new fan assembly using original processor mounting guides as shown in Figure 6. Note: Some components not shown for clarity. Existing CD80AE Dimming Rack...