Download Print this page

Pearl MXA Series Installation And Operating Instructions Manual

Horizontal multistage pumps

Advertisement

Quick Links

1. GENERAL INFORMATION
Before using the product carefully read the information
contained in this instruction manual, the manual should be kept
for future reference.
Italian is the original language of this instruction manual, this
language is the reference language in case of discrepancies in
the translations.
This manual is part of the essential safety requirement and must
be retained until the product is finally decommissioned.
The customer, in case of loss, can request a copy of the manual
by contacting the manufacturer or their agent, specifying the
type of product data shown on the label of the machine (see 2.3
Marking)
Any changes, alterations or modifications made to the product or
part of it, not authorized by the manufacturer, will revoke the "CE
declaration" and warranty.
This appliance should not be operated by children younger
than 8 years, people with reduced physical, sensory or mental
capacities, or inexperienced people who are not familiar with the
product, unless they are given close supervision or instructions
on how to use it safely and are made aware by a responsible
person of the dangers its use might entail.
Children must not play with the appliance. It is the user's
responsibility
to
clean
Children should never clean or maintain it unless they are given
supervision.
Do not use in ponds, tanks or swimming pools or where people
may enter or come into contact with the water.
Read carefully the installation section which sets forth:
- The maximum permissible structural working pressure
(chapter 3.1).
- The type and section of the power cable (chapter 6.5).
- The type of electrical protection to be installed (chapter 6.5).
1.1. SYMBOLS
To improve the understanding of the manual, below are
indicated the symbols used with the related meaning.
Information and warnings that must be observed,
otherwise there is a risk that the machine could dam-
age or compromise personnel safety.
The failure to observe electrical information and
warnings, could damage the machine or compromise
personnel safety.
Information and warnings that must be observed,
otherwise there is a risk that compromise personnel
safety.
i
Notes and warnings for the correct management of the
machine and its parts.
INSTALLATION AND OPERATING INSTRUCTIONS
and
maintain
the
appliance.
MXA-MSC
Horizontal multistage pumps
Operations that could be performed by the final user.
After carefully reading of the instructions, is responsible
for maintenance under normal conditions. They are
authorized to affect standard maintenance operations.
Operations that must be performed by a qualified elec-
trician. Specialized technician authorised to affect all
electrical operations including maintenance. They are
able to operate with in the presence of high voltages.
Operations that must be done performed by a qualified
technician. Specialized technician able to install the
device, under normal conditions, working during "main-
tenance", and allowed to do electrical and mechanical
interventions for maintenance. They must be capable of
executing simple electrical and mechanical operations
related to the maintenance of the device.
Indicates that it is mandatory to use individual protec-
tion devices.
Operations that must be done with the device
OFF
switched off and disconnected from the power
supply.
Operations that must be done with the device
ON
switched on.
1.2. MANUFACTURER NAME AND ADDRESS
PD Water Systems
3000 W. 16 Ave. Miami, FL 33012
Tel: (954) 4749090 | Fax: (954) 8890413
info@pdwatersystems.com | www.pdwatersystems.com
1.3. AUTHORIZED OPERATORS
The product is intended for use by expert operators divided into
end users and specialized technicians.
(see the symbols above).
It's forbidden, for the end user, carry out operations which must
be done only by specialized technicians. The manufacturer
declines any liability for damage related to the non-compliance
of this warning.Provide enough clearance around the unit for
motor ventilation and for filling and draining the pump.

Advertisement

loading

Summary of Contents for Pearl MXA Series

  • Page 1 MXA-MSC Horizontal multistage pumps INSTALLATION AND OPERATING INSTRUCTIONS 1. GENERAL INFORMATION Before using the product carefully read the information contained in this instruction manual, the manual should be kept for future reference. Italian is the original language of this instruction manual, this language is the reference language in case of discrepancies in the translations.
  • Page 2: Technical Features

    1.4. WARRANTY For the product warranty refer to the general terms and XXXXXXX XXXXXXX conditions of sale. Q min/max X/X US gpm H max/min X/X ft TEFC The warranty covers only the replacement and the repair X kW (XHp) n XXXX/min S.F.
  • Page 3: Installation

    6.3. UNPACKING Maintenance operations, requiring full or partial disassembly of the device, must be done only after Inspect the device in order to check any damages which disconnection from the supply. may have occurred during transportation. 4.2. SAFETY DEVICES Package material, once removed, must be discarded/recycled according to local laws of the destination country.
  • Page 4: Startup And Operation

    Always follow the National Electrical Code (NEC), or the Before starting, check that the shaft turns by hand. For Canadian Electrical Code, as well as all local, state and provincial this purpose use the screwdriver notch on the shaft end on the codes.
  • Page 5: Maintenance

    The appliance must be switch off every time there are faults. casing before dismantling the pump (par. 13 fig. 5). (see troubleshooting). For dismantling and re-assembly see construction in the cross section drawing. The product is designed for a continuous duty, the switch off is performed by disconnecting the power supply by means the 9.
  • Page 6 PROBLEM POSSIBLE CAUSE SOLUTION Check that the mains frequency and voltage correspond to the Unsuitable power supply electrical characteristics shown on the indicator plate. Connect the power supply cable to the terminal board correctly. Check that the thermal overload protection is set correctly (see Incorrect electrical connections data on the engine indicator plate) and make sure that the fuseboard upline of the engine has been properly connected.
  • Page 7 PROBLEM POSSIBLE CAUSE SOLUTION Rotating part unbalanced Check that no solid bodies are obstructing the rotor. Worn bearings Replace the bearings. Pump and pipes not firmly attached Anchor the delivery and suction piping as needed. Flow too strong for the diameter of the Use bigger diameters or reduce the pump flow.

This manual is also suitable for: