Download Print this page

Keis Heated Hi-Power BodyWarmer Operating Instructions page 2

Advertisement

Keis_A5_hi-power-bodywarmer V 2014
HI POWER
BODYWARMER
+
Fused Connection Lead
Auxiliary Power
Socket for use
with Keis 12V
Gloves ONLY
Auxiliary Power
Socket for use
with Keis Insoles
or Trousers
Inside of garment
Pocket containing 12v Supply Lead
SAFETY & ENVIRONMENT FIRST
Do not dispose of electrical equipment with standard domestic waste.
Contact your local authority for disposal information specific to your area.
WARNING
I This electrically heated garment must be used strictly in accordance with the
manufacturer's instructions. Failure to observe this notice may lead to increased risk of
burns and fire resulting in injury or death.
I Switch the garment off immediately and check the affected skin at any sign of irritation
or sensation of excessive heat.
I Do not use the garment when wet. If it becomes wet during use disconnect
immediately from the power source.
I Never leave the garment unattended when switched on.
I Always wear clothing between the heated garment and the skin. Do not wear directly in
contact with the skin.
I This product is unsuitable for young children.
I Do not use this product if you suffer from: heightened or impaired temperature
sensitivity; an inability to sense temperature extremes; circulatory problems resulting
from diabetes or other medical conditions.
I Use this product with 12V systems ONLY.
I Always observe the correct fuse rating – See 'Manage your Fuses'.
I Do not modify or disassemble any part of the system in any way.
I Do not use if the product is visibly damaged.
Do not operate the controller whilst driving!
MANAGE YOUR FUSES
WARNING For your safety it is essential to manage
Connector Block
the fusing to your Keis Heated Apparel.
A selection of up to f
the current drain and potential combinations of the
garments.
Link Wire
On delivery the fuse holder in the supply loom may be
delivered without a fuse. To calculate the fuse value
required simply add the current draws for each of the
garments supplied by the 12V Supply Loom and use
the lowest rated fuse that exceeds the calculated
current.
NOTE: A fuse value below the value required may fail
in use.
FOR EXAMPLE: Sleeved Jacket consumes 7A, Insoles
consume 1.3A. Therefore total is 8.3A. Next fuse value
above this is 10A so use a 10A fuse.
Outside of garment
Power Input Lead
for Heat Controller
PREPARING A VEHICLE TO POWER YOUR KEIS HEATED GARMENT
(not supplied) in
Your Keis heated garment is designed to be powered from a 12V source such as a vehicle battery or
the exterior
Lithium Battery Pack.
Controller Pocket
To power your Keis garment from a vehicle battery attach the Fused Connection Lead directly to the
battery or other live 12V source taking into account any safety notices issued by the vehicle
manufacturer and observing the polarity Red +ve and Black -ve.
Position the power socket so it is in a convenient position to power your garment and secure if necessary
using cable ties or tape ensuring that it cannot become trapped, damaged or interfere with the normal
operation of the vehicle.
WARNING Always connect the Red +ve lead to the battery first.
POWERING YOUR KEIS GARMENT FROM A VEHICLE POWER SOURCE
Your Keis heated garment must be powered from the vehicle battery via the Fused Connection Lead as
installed above or the optional Cigarette Lighter/Accessory Plug. Ask your dealer for details or visit
www.keisapparel.co.uk.
To operate locate the 12v Supply Lead located in the pocket inside the garment. Simply connect or
disconnect this to and from the power source as required. An optional on/off switch is available.
POWERING ACCESSORIES VIA YOUR KEIS HI-POWER BODYWARMER
Your Keis Hi-Power Bodywarmer has dedicated power outputs for Gloves, Trousers and Insoles.
NOTE: These outputs remain live all the time the garment is connected to a power source and are not
affected by devices connected in the Controller Pocket. To control accessories powered by these sockets
separate or integral controllers will be required.
USING A TEMPERATURE CONTROLLER
NOTE: For ultimate comfort this garment is best controlled by a Keis Temperature
Controller. Ask your dealer for details or visit www.keisapparel.co.uk.
Open the Controller Pocket and locate and remove the link wire from the connection block and replace
with the Controller. When using the garment without the Controller simply unplug the Controller and
reconnect the link wire to the connection block inside the
Controller Pocket.
NOTE: The Link Wire or a Controller must be in place for the garment to heat.
Garment
fuses is supplied depending on
Outer Gloves
(Pair)
IUnder Gloves
(Pair)
Lo Power
Bodywarmer
Hi Power
Bodywarmer
Sleeved
Jacket
Trousers
Insoles (Pair)
Current
Fuses
Colour
Draw
3A
Purple
5A
Tan
1.0A
7.5A
Brown
1.0A
10A
Red
15A
Blue
1.5A
NOTE: The potential
current drain when using
3.3A
several garments can be
excessively high in some
7A
situations. It is your
responsibility to ensure the
3.3A
power source can provide
the current required in
1.3A
such circumstances.

Advertisement

loading

This manual is also suitable for:

X20