  • Page 2: Operation

    Operation • Bright-time is a waterproof, 4 channel, real time clock • Each channel may be programmed with up to 8 timing entries • The timing entries may be programmed to operate in a continuous ‘TIMED’ mode or a pulsed ‘CYCLIC’ mode •...
  • Page 3: Installation Diagram

    Installation Diagram NO C GND NO C GND NO C GND NO C GND ~230V NO C GND NO C GND NO C GND NO C GND...
  • Page 4 With the links in place, the relevant outputs will supply 24V DC Channel 1 - LK1 & LK2 Channel 2 - LK3 & LK4 Channel 3 - LK5 & LK6 Channel 4 - LK7 & LK8 G756-3 BRIGHTWELL DISPENSERS Links in place L N E NO C GND NO C GND...
  • Page 5 Channel 1 - LK1 & LK2 Channel 2 - LK3 & LK4 Channel 3 - LK5 & LK6 Channel 4 - LK7 & LK8 G756-3 BRIGHTWELL DISPENSERS Links removed L N E NO C GND NO C GND...
  • Page 6: Programming Instructions

    Programming Instructions BRIGHTWELL Channel 1 Wednesday Channel 2 14:52:02 Channel 3 Tel:+44 1273 513566 Channel 4 Shown above are the default screens available when in operating mode. Either screen can be selected using the + and - keys. The second screen shows the current state of each channel.
  • Page 7 Program channel, Clear timing entries and Set up system options will require a PIN number before allowing access. When selecting one of these options, the following screen will be displayed. Use the + and - key to enter your 4 digit access code and PROGRAM MODE press the ACCEPT key to move on.
  • Page 8 Channel/Entry Number Mode; TIMED (Continuous); Operational Days CYCLIC (Pulsed) Edit TIMED Start time; HRS:MIN START M------ 00:00 DURATION 00:00:00 Run duration; HRS:MIN:SEC • Using the + and - keys, select the mode that you wish the channel entry to operate in, TIMED or CYCLIC •...
  • Page 9 Clearing Timing Entries (access code protected) PROGRAM MODE Using the + and - keys, select the Channel that you wish Clear timing entries Channel 1 to clear. PROGRAM MODE Press ACCEPT to clear ALL the timing entries of the Clear timing entries Channel 1 chosen channel.
  • Page 10 Viewing Total run time PROGRAM MODE Using the + and - keys, select the Channel that you wish View total time Channel 1 to view the total run time of. CHANNEL 1 TOTAL TIME The total run time will be displayed along with the date SINCE --/--/-- --:-- =----Hrs --min --sec and time that it was last reset.
  • Page 11 ON, then it will be switched OFF and if the channels is OFF, then it will be switched ON. An OVER-RIDDEN channel will only remain in this state until the next programmed ON/ OFF time. The OVER-RIDE feature only works from the default screens. BRIGHTWELL Press the OVER-RIDE key to enter the OVER-RIDE Wednesday menu. 14:52:02...
  • Page 12: Specification

    Specification OVER- RIDE Enclosure: IP66M ABS Supply: ~230V 50/60Hz Fusing: T400mA Volt free - 250V 6A Maximum Outputs: DC - 24V DC 0.7A Clock Accuracy: ±4 Min/Yr EMC 89/336/EEC - EN50081-1:EN50082-1 Approvals: LVD 72/23/EEC - EN60335-1...
  • Page 16 Norton Road Enschede Newhaven NL-7524 DN BN9 OJF The Netherlands All Orders: +44 (0)1273 513566 Sales: +44 (0)1273 511300 Sales: +31 (0)53 4344018 Fax: +44 (0)1273 516134 Fax: +31 (0)53 4344022 www.brightwell.co.uk brightmail@brightwell.co.uk 2000 Brightwell Dispensers Ltd. All rights reserved.