K-Stove KS 8020HY Instruction Manual

Freestanding pellet stove with hot water

Advertisement

FREESTANDING PELLET STOVE
WITH HOT WATER
(PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE)
Please register your K-Stove pellet stove
@
www.kstove.com

Advertisement

Table of Contents
loading

Summary of Contents for K-Stove KS 8020HY

  • Page 1 FREESTANDING PELLET STOVE WITH HOT WATER (PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE) Please register your K-Stove pellet stove www.kstove.com...
  • Page 2: Table Of Contents

    FREESTANDING PELLET STOVE WITH HOT WATER (PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE) A LIFETIME OF WARMTH *Please read this entire manual before installation and use of this pellet fuel burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. *Save these instructions! INSTALLER: THIS MANUAL MUST STAY WITH APPLIANCE! INTRODUCTION ..................3...
  • Page 3: Introduction

    INTRODUCTION Dear Customer, First, we wish to thank you for the preference granted to K-Stove ESIGN products and in particular to a stove from our Hydro line. In order to obtain the optimum performance of the stove and to enjoy the warmth and sense of wellness being that the warmth of the flame can spread in your home, we recommend that you read this manual carefully before making the first start- up of the stove.
  • Page 4: Warning And Warranty

    1.1. SAFETY INSTRUCTIONS • Installation, electrical connection, check that the installation and maintenance are performed only by qualified and authorized by K-Stove DESIGN. • Install the heater according to the regulations of the place, region or state. • This appliance is not intended to be used by people (including children) with reduced physical, sensory, mental, or with limited experience and knowledge, unless they are trained to use the device or supervised by the person who is fully responsible for his security.
  • Page 5: Operating Instruction

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL • Any liability for misuse of the product is solely responsible and design raises K-Stove from all civil and criminal responsibility ; • Any type of unauthorized tampering or substitution of non-original parts of the stove can be dangerous to the operator safety and lifts K-Stove DESIGN from all civil and criminal.
  • Page 6: Important Information For Correct Disposal Of The Product In Accordance With Ec Directive 2002/96/Ec

    • Never turn on any heater with flammable materials in the event of failure of the ignition system. INFORMATION In case of any problems, get in touch with your dealer, or a qualified engineer authorized by K-Stove, and if a repair is necessary, insist on the use of original spare parts.
  • Page 7: Exclusions

    The guarantee does not cover any parts which may be found to be faulty as a result of negligence or carelessness in use, or of incorrect maintenance, or of installation not complying with the K-Stove specification (see the relevant chapters in this user manual).
  • Page 8: Operating Environment

    K-Stove pellet stoves run exclusively on pellets with a diameter of 6 mm (European countries) with lengths. IMPORTANT! Installation and assembly of the stove must be carried out by qualified personnel.
  • Page 9: Connection To The External Air Intake

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL where there is no fire hazard such as: garages, sheds, storage of combustible materials, etc., strictly complying with the requirements under current rules. It is absolutely prohibited to installation the stove in bedrooms, bathrooms, and where it is already installed another d heating device without adequate airflow (fireplace, stove, etc..).
  • Page 10: Connection To The Chimney

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL It should always use pipes and fittings with appropriate seals to ensure air‐tightness in order to avoid possible harmful CO fumes into the environment. All sections of the exhaust duct must be inspect able and removable to allow for periodic cleaning of the interior, which is necessary for the proper functioning of the system (T-piece with inspection).
  • Page 11 (sometimes) by placing the exhaust duct from the side opposite to the direction of the wind (4) IMPORTANT! The operation of the pellet stove is noticeably sensitive to the conformation and position of the flue which is adopted. Hazardous conditions can only be overcome by suitable setting-up of the stove carried out by qualified K-Stove personnel.
  • Page 12 Full compliance of the system, per the applicable law, and issuing the certificate. K-Stove disclaims any liability for damage to persons or property or in the event of failure or improper operation, if not complied with the above warnings, and issued the necessary certificates of compliance enforcement work in an appropriate manner.
  • Page 13: Preparation And Unpacking

    If the flue of the stove is forced or improperly used to lift or placed into position , it will compromise beyond repair , the operation , and K-Stove DESIGN is not considered in any way responsible for such a maladroit and / or neglect in the work, so in these conditions any Recovery operations are excluded from warranty.
  • Page 14 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL 3.3.1.CONNECT TO THE SYSTEM Carry out the connections to the connections illustrated in the diagram corresponding to the previous page taking care to avoid tension in the pipe and under sizing of the pipes IMPORTANT!!! IT IS NECESSARY TO PROVIDE THE PROPER CLEANING THE WHOLE SYSTEM BEFORE YOU CONNECT THE STOVE TO ELIMINATE WASTE AND...
  • Page 15: Filling The Water Network

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL Always install the heater upstream of the valve gate,to isolate the same water system or move it, if necessary, to perform routine maintenance (or extraordinary maintenance) .Connect the heater hoses for not using the over pressure constrain the stove to allow the stove to lower the pressure.
  • Page 16: Kit Water Production

    “state of art” performance, attesting the conformity of the work in compliance with laws and regulations. K-Stove DESIGN disclaims any responsibility in case of non-compliance to the above, especially in the absence of proof of certification work in a “STATE OF ART”...
  • Page 17: Heating Installation In Combination With A Storage Tank

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL 3.5.2 HEATING INSTALLATION IN COMBINATION WITH A STORAGE TANK...
  • Page 18: Heating Installation Diagram In Combination With A Boiler

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL 3.5.3. HEATING INSTALLATION DIAGRAM IN COMBINATION WITH A BOILER...
  • Page 19: Operation

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL 4.Operations Instructions - Quick reference guide...
  • Page 20 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL The switching on Stage, which has the duration of Switching on / switching off about 5-15 minutes, are necessary to the resistance The heater switching on and switching off is to carry the pellets at the switching on temperature, (depends from the heater).
  • Page 21 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL HOWEVER, It is possible to switch off the heater in every functioning phase. The switching off performs pressing the key ON/OFF for two seconds, make sure the stove is under your eyes, until its “Stabilisation”, After push the button, then the phrase "Cooling"...
  • Page 22 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL FLAME POWER VARIATION Depending on the heating desire, fuel intake quantity can be adjusted from few to large by the fuel intake Button. For example, Pressing the key the feed quantity can be changed, the display shows the selected power. LOW POWER P3 MINIMUM POWER P4 MAXIMUM POWER P1...
  • Page 23 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL DESIRED TEMPERATURES SETTING Pressing the keys , on the display The temperature is selecting. How to Check the Room temperature, Exhaust (Smoke) Temperature, Safety (Protection) Temperature which is located under the hopper.--------------- By Push button The number with “R”...
  • Page 24 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL 3.) How to set details Setup - Quick reference guide...
  • Page 25 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL CLOCK SETTING Press the key , the time can be amended: You can select week or time by keys also using to change the day or time , to save the correct data by press and move to next stage.
  • Page 26 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL TIMER SETTING Press the key into next stage: On the display the following wording will appear With this function you program the heater for a weekly programming, associating the switching on and the switching off at the pre fixed timetables. You can program daily switching on and switching off for the whole week.
  • Page 27 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL ECO mode SETTING By keeping pressing the key it will appear the following words: Pressing the key , to select the Mode 1 or Mode 2, Mode 2 is for turning to minimum Power, while mode 1 is for stopping the stove.
  • Page 28 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL It means fire put out automatically during It means Igniter failure at the beginning. t the operation, when the exhaust gas Such as: 1. there have clinkers in fire pot. t temperature is below 40-45degree. 2.
  • Page 29 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL Check everything is fine, you can press to delete the Error code !! ATTENTION !! If showing following words when you start the stove, such as: It means temperature sensor 1(exhaust gas It means temperature sensor 1 is open-circuit. temperature sensor) is short-circuit.
  • Page 30 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL 4.) Safety POWER FAILURE After the power failure, the display will show E7. If you have a short cut of power failure, you manually go back to "Stabilization" by clearing the E7 with the "okay button" restart the stove and then keep pressing 3 seconds on the "fire button"...
  • Page 31: Maintenance And Cleaning

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL If the stove cools down below a minimum temperature, then the stove will switch off. This switch off can also occur if pre-heating is too slow. 5. MAINTENANCE AND CLEANING ATTENTION! All cleaning of all parts must be carried out with the stove completely cold and unplugged. The stove does not need much maintenance if used with certified quality pellets.
  • Page 32: Cleaning Of Stainless Steel And Satin-Finish Surfaces

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL ATTENTION! Do not use abrasive products and do not spray the cleaning product on the glass of the painted parts or on the gaskets of the fire door (ceramic fiber cord) 5.1.4. Cleaning of stainless steel and satin-finish surfaces Normally these surfaces do not need to be treated, but if they do, avoid cleaning them with abrasive materials.
  • Page 33: Cleaning The Exchanger And Pipe Unit (Suite/Musa And Club)

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL the soot and ash which has accumulated in the exchanger “H”. Also remove the grate “F” and clean it every 2/3 days as explained in chap. 5.1 ATTENTION: It is advisable to carry out the cleaning of the lower compartment once a week and in any case according to the fuel consumption.
  • Page 34: Check Of Internal Components

    The check of the internal electromechanical components must be carried out only by qualified personnel with technical knowledge of electricity and combustion. If necessary, contact authorized K-Stove retailers. We recommend that an annual maintenance service is carried out, preferably under a programmed service contract.
  • Page 35: Problems / Causes / Solutions

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL stove. 6. PROBLEMS / CAUSES / SOLUTIONS NOTE: All repairs must be performed by a technician with the stove off and disconnected the mains. The control panel of the stove has trouble examine sensors. When the sensor detect the abnormal work temperature (below 40˚C), or the other sensor’s temperature is above 70˚C the auto-control temperature switches will react accordingly.
  • Page 36 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL boiler) degrees on the venting pipe. No power in stove or in the Check the power and wires. If after 15 mins, it does control panel. not work, there must be Or Unplugged on the mother Plug it wrong board...
  • Page 37 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL B. The fire is off due to The level of feeding Adjust the combustion fan's speed Down little wood pellet can be speed is too low burned 5 After ignition the power Pellet feeder unit is off or Check the pellet feeder unit and restart.
  • Page 38 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL Heat exchange tubes are Clean the heat exchange tubes. dirty. 10. Showing "Pressure Vent pipe is blocked Shut down the stove, check the venting pipe Erro" on the display Close the door and unplugged then restart The door is opening Check it and repair it.
  • Page 39: Electrical Diagrams

    PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL ELECTRICAL GENERATOR OPERATION Your stove can be powered with a gas driven electrical generator. However, the generator’s electrical regulator may not be compatible with the stove’s electronics. The higher the quality of the generator, the greater the chance that it is compatible with the stove. 7.electrical diagram...
  • Page 40 PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL Distributor K-Stove pelletstoves: HAVE Verwarming BV Tel. (0318) 488 600 Fax (0318) 488 620 E-mail info@haveverwarming.nl Bezoekadres: Hullerpad 34 6741PA Lunteren The Netherlands...