Troubleshooting Calibration By Distance - Force 5100ex Calibration Manual

Table of Contents

Advertisement

Troubleshooting Calibration By Distance

Error Message
Value below min. Setting to min.
Value above max. Setting to max.
Calibrating Axle Pulses By Distance
Condition
The 5100ex recorded
less than 5000
pulses.
This may be caused
by a disconnected or
intermittent
speedometer signal
or not driving far
enough.
The 5100ex recorded
more than 200,000
pulses.
This may be caused
by excess noise, a
connection to a digital
communication circuit
on the vehicle, or
driving too far.
31
5100ex Calibration Manual
Possible Solutions
Verify the wiring and
connections of the
speedometer cable.
Verify the
Speedometer Type
is set properly.
Increase the Low
Trip Point.
Decrease the High
Trip Point.
Verify the wiring and
connections of the
speedometer cable.
Verify the
Speedometer Type
is set properly.
Decrease the Low
Trip Point.
Increase the High
Trip Point.