Advertisement

Quick Links

EQ Series
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
GENERAL INFORMATION .............................................................................................................. 2
SECTION II.
MECHANICAL INSTALLATION AND PRESSURE TESTING ........................................................... 2
SECTION III.
INITIAL OPERATION ...................................................................................................................... 6
SECTION IV.
CLEANING THE STRAINER BASKET ............................................................................................ 6
SECTION V.
REPLACEMENT PARTS ................................................................................................................ 8
SECTION VI.
STRAINER POT ASSEMBLY TECHNICAL DATA ....................................................................... 9-10
TECHNICAL SUPPORT ................................................................................................................ 11
Read and follow all warning notices and instructions accompanying this product before installing.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
Call (800) 831-7133 (US) for additional free copies of these instructions.
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
CE marking only applies to 50 Hz models:
EQK300, EQK500, EQK750, and EQK1000.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 553-5000
www.pentairpool.com and starite.com
Rev. E 02-12-07
®
Strainer Pot Owner's Manual
SAVE THESE INSTRUCTIONS

Table of Contents

Important Notice
WARNING
1
P/N 350062

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Pool Products EQ Series

  • Page 1: Table Of Contents

    ® EQ Series Strainer Pot Owner's Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. GENERAL INFORMATION ......................2 SECTION II. MECHANICAL INSTALLATION AND PRESSURE TESTING ............2 SECTION III. INITIAL OPERATION ........................6 SECTION IV.
  • Page 2: Section I

    This product is intended for use in swimming pool applications only. It may be mounted directly to a Pentair Pool Products EQ Series pump. This will provide filtration of debris that could damage the pump and will allow the pump to be self-priming in installations up to 10 feet.
  • Page 3 7. Repeat steps 4, 5 and 6 for the lower flange connection unless the strainer is directly attached to a Pentair Pool Products EQ Series pump. 8. Inspect both flange connection(s) to ensure that the flanges of the strainer pot and the connection flanges are in line and that the faces are parallel.
  • Page 4 WARNING It is important that the four tabs on the locking ring be fully overlapped with the four tabs on the strainer pot before performing a pressure test. If the locking ring is under tightened or over tightened so that the tabs do not fully overlap with tabs on the pot a structural failure can occur.
  • Page 5 4. Use only a high quality pressure gage that is certified to be accurate for the pressure for which the test is going to be conducted. Do not rely on the pressure gage included with the filtration system as it may not be sufficiently accurate to conduct a pressure test for the system.
  • Page 6: Initial Operation

    SECTION III. INITIAL OPERATION Verify that the following tasks are completed before energizing the circulation pump. 1. Make sure the O-Ring is on drain plug and that drain plug is tightened hand tight. 2. Fill strainer pot with as much water as it will hold. 3.
  • Page 7 WARNING If the pump has been energized for a period greater than 45 minutes without water flowing through the pump for any reason, the water in the strainer pot may be hot. Attempting to remove the locking ring without removing the drain plug in the pot and allowing the pressure to equalize may result in the hot water rapidly escaping and causing severe personal injury.
  • Page 8: Replacement Parts

    SECTION V. REPLACEMENT PARTS Item Part Description 356700 Clamp Cam & Ramp EQ 356750 Lid EQ Clear 350166 Gasket EQ Lid 357184 Basket EQ Strainer 356725 Pot EQ Strainer 154699 Plug Wire .25 in. Drain LGR 192215 O-ring Drain Plug 356766 O-ring Pot Flange 356789...
  • Page 9: Strainer Pot Assembly Technical Data

    SECTION VI. STRAINER POT ASSEMBLY TECHNICAL DATA A. FRICTION LOSS CURVE PRESSURE DROP ACROSS EQ STRAINER POT Pr. Drop Capacity in U.S. GPM m3/h or m3/men because flow is high B. ENGINEERING SPECIFICATIONS — — — — Rev. E 02-12-07 P/N 350062...
  • Page 10 C. DIMENSIONAL DATA FASTENERS AND O-RING ARE INCLUDED WITH EQ 6 X 6 STRAINER TO CONNECT STRAINER DIRECTLY TO PENTAIR POOL PRODUCTS EQ SERIES PUMP. 43.2 cm IF STRAINER IS TO BE INSTALLED AS A STAND - ALONE (17.0") UNIT, CONNECT BOTH FLANGES PER NOTE 1.
  • Page 11: Technical Support

    Technical and Customer Support (Europe) For technical support questions and product service information, contact: Phone: (0032) 14 25 99 66 - 8 A.M. to 5 P.M. (GMT) Fax: (0032) 14 25 99 73 Technical and Customer Support (United States) For technical support questions and product service information, contact: Sanford, North Carolina (8 A.M.
  • Page 12: Pentair Water Pool And Spa, Inc

    This document is subject to change without notice. EQ Series and the Pentair Pool Products logo are registered trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa, Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

This manual is also suitable for:

Strainer pot

Table of Contents