Adeunis RF WMBUS ANALOG PWR ARF8201CA User Manual

Transceiver analog/digital interface
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

WMBUS ANALOG PWR
Transceiver Analog/Digital Interface
Ce Guide utilisateur s'applique à partir des versions logicielles suivantes :
This User Guide applies from the following firmware versions:
Version RTU : V00.04.00
Version APP : V01.03.04
Adeunis
283 rue Louis Néel - Parc Technologique Pré Roux
38920 CROLLES - France
www.adeunis.com
Guide utilisateur / User Guide
Version 2.0.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WMBUS ANALOG PWR ARF8201CA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Adeunis RF WMBUS ANALOG PWR ARF8201CA

  • Page 1 WMBUS ANALOG PWR Transceiver Analog/Digital Interface Guide utilisateur / User Guide Version 2.0.1 Ce Guide utilisateur s’applique à partir des versions logicielles suivantes : This User Guide applies from the following firmware versions: Version RTU : V00.04.00 Version APP : V01.03.04 Adeunis 283 rue Louis Néel - Parc Technologique Pré...
  • Page 2 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Préambule / Preamble / Präambel / Preambolo / Preámbulo • Ce guide décrit les fonctionnalités du produit adeunis®. Il explique les modes de fonctionnement du produit et la manière de le confi gurer. •...
  • Page 3: Table Of Contents

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 TABLE DES MATIERES FRANCAIS INFORMATIONS PRODUITS ET REGLEMENTAIRES PRÉSENTATION DU PRODUIT 1.1. Description générale 1.2. Encombrement 1.3. Carte électronique 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales 1.4.2 Caractéristiques des interfaces physiques 1.4.3 Compatibilité...
  • Page 4 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 ENGLISH PRODUCTS AND REGULATORY INFORMATION PRODUCT PRESENTATION 1.1. General description 1.2. Dimensions 1.3. Electronic board 1.4. Technical Specifications 1.4.1 General characteristics 1.4.2 Physical interface characteristics 1.4.3 Sensor compatibility PRODUCT OPERATION 2.1.
  • Page 5: Francais

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 FRANCAIS Page of 83...
  • Page 6: Informations Produits Et Reglementaires

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 INFORMATIONS PRODUITS ET REGLEMENTAIRES Information document Titre WMBUS ANALOG PWR - Guide utilisateur Sous-titre Type de document Guide utilisateur Version 2.0.1 Ce document s’applique aux produits suivants : Référence Version firmware WMBUS ANALOG PWR 868 - Replaceable battery ARF8201CA...
  • Page 7 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Déclaration UE de Conformité Nous Adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit : ANALOG LoRaWAN Références :...
  • Page 8 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 INTRODUCTION Tous les droits de ce manuel sont la propriété exclusive de adeunis®. Tous droits réservés. La copie de ce manuel (sans l’autorisation écrite du propriétaire) par impression, copie, enregistrement ou par tout autre moyen, la traduc- tion de ce manuel (complète ou partielle) pour toute autre langue, y compris tous les langages de programmation, en utilisant n’importe quel dispositif électrique, mécanique, magnétique, optique, manuel ou autres méthodes, est interdite.
  • Page 9 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superfl us ont été supprimés. Nous avons fait notre possible afi n que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et poly- éthylène (sachets, feuille de protection en mousse).
  • Page 10 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifi ez si la tension d’alimentation fi gurant dans son manuel d’utilisation corres- pond à votre source. Dans la négative, consultez votre fournisseur. •...
  • Page 11: Présentation Du Produit

    NOTE IMPORTANTE : le démarrage du WMBUS ANALOG PWR ne peut se faire que grâce à un aimant. Description : • Le WMBUS ANALOG PWR d’ADEUNIS RF est un émetteur radio prêt à l’emploi permettant de transformer tout type de capteur 0-10V ou 4-20mA en un capteur communicant sans-fil.
  • Page 12: Encombrement

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.2. Encombrement Valeurs en millimètres 1.3. Carte électronique Antenne interne Module RF Protocole WMBUS Batterie interne Port USB pour configuration produit Borniers à vis pour connexion capteurs Page of 83...
  • Page 13: Spécifications Techniques

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.4. Spécifications Techniques 1.4.1 Caractéristiques générales Paramètres Valeur Alimentation 5-36V continue Courant maximum 90mA Température de fonctionnement -25°C / +70°C Dimensions 105 x 50 x 27mm Poids Boîtier IP 67 Normes radio EN 300-220, EN 301-489, EN 60950 Fréquence...
  • Page 14 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Les valeurs supérieures aux valeurs maximales absolues endommageront le produit. 1.4.2.02 Interfaces 0-10V Le schéma de principe des interfaces 0-10V est le suivant : Valeurs absolues maximum Unité Tension d’entrée minimum Tension d’entrée maximum Caractéristiques électriques Unité...
  • Page 15: Compatibilité Capteurs

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.4.2.04 Alimentation Exigences de l’alimentation externe Unité Tension d’entrée minimum Tension d’entrée maximum Puissance requise minimum Les valeurs supérieures aux valeurs maximales absolues endommageront le produit. 1.4.3 Compatibilité capteurs Exemple de capteurs testés par adeunis®...
  • Page 16: Fonctionnement Du Produit

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2. FONCTIONNEMENT DU PRODUIT 2.1. Modes de fonctionnement NOTE IMPORTANTE : adeunis® utilise le format de données Big-Endian Le produit dispose de plusieurs modes de fonctionnement : MODE PARC Présence d’un aimant sur le produit >6s Envoi commande...
  • Page 17: Fonctionnement Applicatif

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2.2. Fonctionnement applicatif 2.2.1 Transmission périodique Le produit permet la mesure et la transmission périodique des valeurs des capteurs selon le schéma suivant : Produit en veille Période atteinte Mesure entrée A (si activée) Mesure entrée B...
  • Page 18: Transmission Sur Dépassement De Seuil

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2.2.2 Transmission sur dépassement de seuil Le produit permet la détection de dépassement de seuil (haut et bas) pour chaque capteur selon le schéma suivant : Produit en veille Période atteinte Mesure entrée A...
  • Page 19 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Explication des seuils et hystérésis : La période de scrutation des capteurs est fixée à 10 minutes (pour changer cette valeur, contactez le service support). Les paramètres associés à ce mode de fonctionnement sont : •...
  • Page 20: Transmission Sur Événement Suite Déclenchement Entrée Tor

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S324 Décimal 1 200 La valeur du seuil haut de la voie A est : 1 200 000x10=12 000 000nA soit 12mA S325 Décimal 100 000 La valeur de l’hystérésis du seuil haut de la voie A est : 100 000x10=1 000 000nA soit 1mA S326 Décimal...
  • Page 21: Transmission D'une Trame De Vie Journalière

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Exemple : Registre Codage de la valeur Valeur Résultat S301 Décimal Mode événementiel S320 Hexadécimal 0x02 Voie A configurée pour un capteur 4-20mA S322 Hexadécimal 0x01 Voie B configurée pour un capteur 0-10V S321 Hexadécimal 0x1C...
  • Page 22: Mode Test

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2.2.5 Mode TEST Ce mode permet à l’utilisateur de réaliser des essais du produit plus rapidement en réduisant les échelles de temps du mode production et en modifiant le comportement des LEDS. Il est obtenu en positionnant le registre S306 à...
  • Page 23: Configuration Du Produit

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 CONFIGURATION DU PRODUIT La configuration du produit au travers du port micro-USB peut désormais se faire de deux manières : via l’IoT Configurator (application à l’inter- face conviviale) soit par envoi de commandes AT. Pour ouvrir le boitier du produit se reporter au paragraphe 5.1. 3.1.
  • Page 24: Mode Commande

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 3.2.2 Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en téléchargement gratuit à l’adresse suivante : http://www.hw-group.com/products/hercules/index_en.html •...
  • Page 25 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Tableau des commandes AT : Commande Description Exemple de réponse Entrée en mode commande «CM»<cr><lf> ATPIN <PIN> Donne accès aux commandes AT si le registre S304 est différent de 0 AT/V Affiche la version du firmware de l’application et la APPx_Vxx.xx.xx:RTUx_Vyy.yy.yy...
  • Page 26: Description Des Registres

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 3.3. Description des registres A la mise sous tension le produit fonctionne selon la dernière configuration sauvegardée (configuration usine si c’est la première mise sous tension, ou si cette configuration n’a pas été changée). La commande de modification ATS<n>=<m>...
  • Page 27 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S321 Configuration du compor- Hexadécimal Défaut 0x10 tement événementiel de la Bits 0 à 1 : Déclenchement sur seuil voie A • 0 = Aucun • 1 = Bas uniquement •...
  • Page 28: Registres Réseau

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S326 Valeur seuil Bas voie A Décimal Défaut : 0 Pour un capteur 4-20mA : • Unité : x 10nA • Valeurs Min/Max : 400 000 à 2 000 000 Exemple : si S326=600 000, le seuil bas aura une valeur de 600000x10=6 000 000nA soit 6mA Pour un capteur 0-10V :...
  • Page 29 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S222 Clé AES (première Hexadécimal Défaut : 0 partie – MSB) Clé codée sur 32 caractères. Chacun des 4 registres contient 8 caractères. S223 Clé AES (deuxième Hexadécimal Exemple : partie –...
  • Page 30: Description Des Trames

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 4. DESCRIPTION DES TRAMES Le produit transmet des informations brutes en provenance des capteurs en utilisant le protocole Wireless M-BUS. Vous trouverez dans ce chapitre les informations permettant de décoder la trame Wireless M-Bus ainsi que les données utiles. NOTE IMPORTANTE : Le produit n’interprète pas ni ne décode les informations en provenance du capteur.
  • Page 31: Trames D'information Sur La Configuration Du Produit

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 4.2.1.02 Status byte L’octet de statut (status byte) est décomposé de la manière suivante : Alarm Status Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Frame Counter...
  • Page 32 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Code Status PAYLOAD 0x11 Cf Status S324 S325 0x11 0xA0 0x124F80 0x0186A0 Description de la trame : • Octets 2 à 4 : registre 324, seuil haut du capteur voie A •...
  • Page 33: Trame D'information Sur La Configuration Du Réseau

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Dans l’exemple en gris cela donne : • Octets 2 à 4=0x2DC6C0=3 000 000 en décimal : registre 330, la valeur du seuil bas pour la voie B est : 3 000 000 µV soit 3V •...
  • Page 34: Trame De Données

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 4.2.5 Trame de données Cette trame (0x42) contient les valeurs relevées sur les différents capteurs. Code Status PAYLOAD 0x42 Cf Status S320 Valeur lue sur le capteur voie A S322 Valeur lue sur le capteur voie B 0x42...
  • Page 35: Préparation Et Configuration

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5. PRÉPARATION ET CONFIGURATION 5.1. Démontage du boîtier Le produit est livré démonté, de sorte à pouvoir accéder à la partie basse de l’électronique. Cette partie permet le branchement du ou des cap- teurs sur les borniers à...
  • Page 36: Câblage Des Capteurs Analogique

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5.4. Câblage des capteurs analogique Exemple de montage capteur(s) Analogique(s) Alimentation électrique Exemple : 10-29V, 100mA (dépendant des besoins du capteur) Alim.externe + Alim.externe - Voie 1 4-20mA 0-10V 4-20mA Voie 2 0-10V...
  • Page 37: Fermeture Du Boîtier

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5.6. Fermeture du boîtier Une fois les étapes précédentes effectuées, vous pouvez fermer le boiter du WMBUS ANALOG PWR. Procédure : Assurez-vous que le joint d’étanchéité est bien en place sur la semelle Clipser la carte électronique sur la semelle du boîtier.
  • Page 38: Démarrage Du Produit Via Aimant

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5.7. Démarrage du produit via aimant Une fois la configuration du produit effectuée et son montage finalisé, le produit est prêt à être démarré. Le démarrage s’effectue à l’aide d’un aimant que l’on appose sur la partie haute du produit (cf schéma ci-dessous). L’aimant doit être maintenu en position au minimum 6 secondes de sorte à...
  • Page 39: Installation Et Utilisation

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 6. INSTALLATION ET UTILISATION 6.1. Positionnement correct des émetteurs Deux règles sont primordiales pour une optimisation des portées radio. • La première consiste à positionner votre produit le plus haut possible. •...
  • Page 40: Fixation Par Vis

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Pour retirer celui-ci, tirer vers le bas sur le levier jusqu’à ce que les Ergots ergots de blocage soient face à une partie dégagée et retirer le levier Partie dégagée 6.2.2 Fixation par vis Le produit est livré...
  • Page 41: Historique Du Document

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 6.2.3 Fixation Rail-DIN Ce système, intégré au boîtier, permet de fixer le produit sur un rail standard de 35mm • Pour installer le boîtier, placer les inserts supérieurs sur le rail et abaisser le produit pour le clipser •...
  • Page 42: English

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 ENGLISH Page of 83...
  • Page 43: Products And Regulatory Information

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 PRODUCTS AND REGULATORY INFORMATION Document Information Title WMBUS ANALOG PWR - User Guide Sub-title Document type User Guide Version 2.0.1 This document applies to the following products : Référence Version firmware WMBUS ANALOG PWR 868 - Replaceable battery ARF8201CA...
  • Page 44 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 EU Declaration of Conformity Adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product: Apparatus model/Product: ANALOG LoRaWAN Type:...
  • Page 45 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 INTRODUCTION All rights to this manual are the exclusive property of adeunis®. All rights reserved. Copying this manual (wit- hout written permission from the owner) via printing, copying, recording or by any other means, translating this manual (in full or partially) into any other language, including all programming languages, using any electrical, mechanical, magnetic or optical devices, manually or any by other methods, is prohibited.
  • Page 46 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 ENVIRONMENTAL RECOMMENDATIONS All superfl uous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (fi ller material) and polyethylene (packets, foam protective sheets).
  • Page 47 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier. •...
  • Page 48: Product Presentation

    IMPORTANT NOTE: The WMBUS ANALOG PWR can only be started with a magnet. Description: • The ADEUNIS RF WMBUS ANALOG PWR is a ready-to-use radio transmitter enabling any type of 0-10V or 4-20mA sensor to be converted into a wireless communicating sensor. •...
  • Page 49: Dimensions

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.2. Dimensions Values in millimeters 1.3. Electronic board Internal antenna RF module WMBUS protocol Internal battery USB port for product configu- ration Screw terminals for connecting sensors Page of 83...
  • Page 50: Technical Specifications

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.4. Technical Specifications 1.4.1 General characteristics Parameters Value Power supply 5-36V continue Maximal power 90mA Working temperature -25°C / +70°C Dimensions 105 x 50 x 27mm Weight Casing IP 67 Radio standards EN 300-220, EN 301-489, EN 60950 Frequency...
  • Page 51 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.4.2.02 0-10V interfaces The schematic diagram of the 0-10V interfaces is the following: Absolute maximum values Units Minimum input voltage Maximum input voltage Electrical characteristics Units Minimum input voltage Maximum input voltage Equivalent input impedance 337,3 (+/-0,2%)
  • Page 52: Sensor Compatibility

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 1.4.2.04 Power supply External power supply requirement Unit Minimum input voltage Maximum input voltage Minimum power required Values higher than the absolute maxima would damage the product. 1.4.3 Sensor compatibility Examples of sensors tested by adeunis®...
  • Page 53: Product Operation

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2. PRODUCT OPERATION 2.1. Global Operation Important: adeunis® use the most significant byte first format. The product has several operating modes: PARK MODE Presence of a magnet on the product >6s Command sending by serial link COMMAND MODE...
  • Page 54: Application Operation

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2.2. Application operation 2.2.1 Periodic transmission The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram: Product in standby Period reached? Measurement input A...
  • Page 55: Transmission On Exceeding Of The Threshold

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2.2.2 Transmission on exceeding of the threshold The product allows detection threshold overrun (upper and lower) for each sensor according to the following diagram: Product in standby Period reached? Measurement input A (if enabled) Measurement input B...
  • Page 56 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Explanation of thresholds and hysteresis: high threshold High threshold - high threshold hysteresis Sensor value Low threshold + low threshold hysteresis Low threshold Low alarm enabling Low alarm disabling High alarm enabling High alarm disabling The monitoring period by the sensors is fixed at 10 minutes (to change this value, contact the Technical Support Department).
  • Page 57: Transmission On Event Of Digital Input

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S324 Decimal 1 200 000 The value of the high threshold of channel A is: 1 200 000x10=12 000 000nA so 12mA S325 Decimal 100 000 The value of the hysteresis of the high threshold of channel A is: 100 000x10=1 000 000nA so 1mA S326 Decimal...
  • Page 58: Transmission Of A Daily Keep Alive Frame

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Register Value encoding Value Result S301 Decimal Event mode S320 Hexadecimal 0x02 Channel A configured for a sensor 4-20mA S322 Hexadecimal 0x01 Channel B configured for a sensor 0-10V S321 Hexadecimal 0x1C...
  • Page 59: Test Mode

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 2.2.5 TEST Mode This mode allows the user to perform tests of the product more quickly by reducing the time scales of the production mode and modifying the behavior of the LEDs. It is obtained by positioning register S306 at the value 2 in the COMMAND mode.
  • Page 60: Device Configuration

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 DEVICE CONFIGURATION The product can be configured using the USB interface and in two modes: or using the IoT Configurator (a user friendly application, recommend- ed) or using the AT command. 3.1.
  • Page 61: Command Mode

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 3.2.2 Command mode Use a COM port terminal in order to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking on the following link: https://www.hw-group.com/products/hercules/index_en.html •...
  • Page 62 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Table of AT commands: Command Description Reply example Input request in command mode CONNECTING... <cr><lf> CM<cr><lf> ATPIN <PIN> Gives access to AT commands if register S304 is different of 0 AT/V Feeds back the version of the APPLICATIF and APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_WM-...
  • Page 63: Description Of The Registers

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 3.4. Description of the registers On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configura- tion has not been changed).
  • Page 64 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S320 Configuration of the channel A sensor Hexadecimal Default : 0x00 Bits 0 to 3 : Type • 0 = none • 1 = 0-10 V • 2 = 4-20 mA Bits 4 to 7: Identifier (free to use) WARNING : if none of the channels (A et B) is configured (value = None), the product will send the...
  • Page 65: Network Registers

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S326 Low threshold value channel A Decimal Default : 0 For a 4-20mA sensor: • Unit: x 10nA • Min/Max values: 400 000 to 2 000 000 E.g.: if S326=600 000, the low threshold will have a value of 600000x10=6 000 000nA i.e.
  • Page 66 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 S222 AES key (first section Hexadecimal Default : 0 – MSB) Encoded key on 32 characters. Each of the 4 registers contains 8 characters. S223 AES key (second section Hexadecimal –...
  • Page 67: Description Of The Frames

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 4. DESCRIPTION OF THE FRAMES The product transmits raw information from the sensors using the Wireless M-BUS protocol. In this chapter, you will find information for decoding the Wireless M-Bus frame and useful data. IMPORTANT NOTE: The product does not interpret or decode information from the sensor.
  • Page 68: Product Configuration Information Frames

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Details of the fields: • Frame counter: Frame counter, it increments at each transmission and allows the user to see quickly if a frame has been lost. It counts from 0 to 7 before looping back.
  • Page 69 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 In the example in grey this gives: • Bytes 2 to 4=0x124F80=1,200,000 in decimal: register 324, the value of the high threshold for channel A is: 1,200,000x10=12,000,- 000nA i.e.12mA •...
  • Page 70: Network Configuration Information Frame

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 4.2.3 Network configuration information frame During the passage into operation mode (from the Park or Command Mode), the following frame (0x20) representing the network configuration of the product is transmitted: Code Status PAYLOAD...
  • Page 71: Summary Of The Conditions Of The Transmission Of The Uplink Frames

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 Frame description: • Byte 2: Type of the sensor on channel A. Configured by the user (register 320). • Bytes 3 to 5: Value measured on channel A. • If the type of sensor is 0-10V: The value is expressed in µV •...
  • Page 72: Preparation And Configurations

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5. PREPARATION AND CONFIGURATIONS 5.1. Disassembling the casing The product is delivered disassembled so that you can access the lower part of the electronics. This part enables the sensor or sensors to be connected to the screw terminals as well as access to the configuration switches.
  • Page 73: Wiring Of Analog Sensors

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5.4. Wiring of analog sensors Example of analog sensor(s) assembly Electric power supply example: 10-29 V, 100 mA (depending on the sensor’s needs External power supply + External power supply - Channel 1 4-20mA 0-10V...
  • Page 74: Closing The Casing

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5.6. Closing the casing Once previous stages have been carried out, you can close the casing of the WMBUS ANALOG PWR Procedure: Make sure that the seal is properly positioned on the base Clip the electronic board onto the casing’s base.
  • Page 75: Starting Up The Product Using A Magnet

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 5.7. Starting up the product using a magnet Once the product has been configured and its assembly has been finalized, the product is ready to be started up. The start-up is carried out using a magnet which you place on the upper part of the product (cf. the diagram below). The magnet must be held in position for at least 6 seconds so as to confirm the start-up of the product.
  • Page 76: Installation And Use

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 6. INSTALLATION AND USE 6.1. Correct positioning of the product There are two key rules for optimizing radio ranges. • The first one consists of positioning your product as high as possible. •...
  • Page 77: Fixing With Screws

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 To optimise fastening onto a tube or mast, we recommend you Pins remove the Rail-DIN locking/unlocking lever. To remove it, pull the lever down until the locking pins are opposite Freed up part a freed-up part and then remove the lever 6.2.2 Fixing with screws...
  • Page 78: Din-Rail Fixing

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 6.2.3 DIN-Rail fixing This system, integrated into the casing, enables the product to be fastened onto a standard 35 mm rail. • To fit the casing, place the upper inserts on the rail and lower the product to clip it into position. •...
  • Page 79: Deutsch Vorschriften

    WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 DEUTSCH Vorschriften Page of 83...
  • Page 80 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 HAFTUNGSAUSSCHLUSS Dieses Dokument und die Nutzung aller darin enthaltenen Informationen setzt das Einverständnis mit den Bestim- mungen und Bedingungen von adeunis® voraus. adeunis® übernimmt keine Garantie für die Richtigkeit oder Vollständigkeit des Inhalts dieses Dokuments und behält sich das Recht vor, jederzeit und ohne Vorankündigung Änderungen an den Produktspezifi...
  • Page 81 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 VORBEMERKUNG Alle Rechte an dieser Anleitung liegen ausschließlich bei . Alle Rechte vorbehalten. Die Vervielfältigung dieser Anleitung (ohne schriftliches Einverständnis des Eigentümers) mittels Drucken, Kopieren, Speichern oder in ande- rer Weise, die Übersetzung dieser Anleitung (vollständig oder teilweise) in jedwede Sprache, einschließlich aller Programmiersprachen, unter Verwendung jeglicher elektrischer, mechanischer, magnetischer, optischer, manueller Geräte oder anderer Methoden, ist untersagt.
  • Page 82 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 UMWELTSCHUTZHINWEISE Es wurden alle überfl üssigen Verpackungsmaterialien vermieden. Wir haben uns bemüht, dass die Verpackung leicht in drei Materialarten getrennt werden kann: Pappe (Schachtel), expandiertes Polystyrol (Puff ermaterial) und Polyethylen (Tüten, Schaumstoff -Schutzlage). Ihr Gerät besteht aus recycelbaren Materialien, die im Falle einer Demontage durch ein Fachunternehmen wiederverwendet werden können.
  • Page 83 WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.1 GEBRAUCHSHINWEISE • Überprüfen Sie vor Benutzung des Systems, ob die in dessen Betriebsanleitung angegebene Versorgungsspan- nung mit Ihrer Stromquelle übereinstimmt. Falls nicht, wenden Sie sich an Ihren Lieferanten. • Stellen Sie das Gerät auf eine ebene, feste und stabile Oberfl...

Table of Contents