Cleaning - Sony TC-WR350Z Operating Instructions Manual

Stereo cassette deck
Hide thumbs Also See for TC-WR350Z:
Table of Contents

Advertisement

Additional Information

Cleaning

Head assembly of deck B
Erasing head
Recording/playback head
DECK A
COUNTER RESET
0
POWER
p
Cleaning the heads and tape path
Clean the heads and tape path of the tape deck after
every 10 hours of operation to guard against:
• low-quality sound
• a decrease in sound level
• excessive wow or flutter
• sound dropout
• incomplete erasure
• impairment of recording function
To ensure better recording, we recommend that you
clean the heads and tape path before every recording.
1
Press § to open the cassette holder. Grasp the
front cover on both sides and gently lift to remove
it.
2
With the tape deck turned off, wipe the heads, the
pinch rollers and the capstans with a cotton swab
slightly moistened with alcohol or a commercially
available cleaning fluid for tape decks.
3
Replace the front cover.
12
Pinch rollers
Capastans
AUTO
REC LEVEL
DIRECTION
DOLBY NR
D
a RELAY
OFF
B
C
4
5
6
3
7
SYNCHRO DUBBING A B
2
8
HIGH/NORMAL
FADER
ARL
1
9
START(DECK B P)
DECK B
PAUSE
REC MUTE
REC
0
10
P
R
r
)
0
)
PHONES
ª
·
p
ª
·
§
§
§
Demagnetizing the heads
After 20 to 30 hours of use, or when you notice a
hissing sound or loss of high frequencies, demagnetize
the heads with a commercially available demagnetizer
for tape decks. Please refer to the instructions of the
demagnetizer.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc-we405Tc-wr661

Table of Contents