Advertisement

E200PS Operation Manual
(Version: V1.02)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E200PS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Estun E200PS

  • Page 1 E200PS Operation Manual (Version: V1.02)
  • Page 2: Table Of Contents

    Contents Preface ........................1 Chapter 1 Product Introduction ................3 1.1 Characteristic ....................3 1.2 Operation Panel ..................... 3 1.3 Display ......................4 Chapter 2 Operation Example ................. 5 2.1 Single-Step ....................5 2.1.1 Background ......................5 2.1.2 Analysis ......................5 2.1.3 Procedure ......................
  • Page 3: Preface

    Attention  Copy right is preserved by ESTUN. It is not allowed to add or delete part or all of the manual content without ESTUN’s consent. Do not use part or all of manual content for the third party’s design.
  • Page 4 E200PS Operation Manual Caution Sign The following symbols with an adjoining safety advice or notice are used in this document. You have to read the safety advices carefully and adhere them strictly! Risk of injury! If you do not adhere the safety advise adjoining this symbol, there is...
  • Page 5: Chapter 1 Product Introduction

    Chapter 1 Product Introduction 1.1 Characteristic E200PS CNC device is a very suitable for torsional axis shearing machine, providing solutions for most of the wiggle or gate machine both complete and economy, with high performance, flexible configuration, compact structure, easy to use, high reliability characteristic: ...
  • Page 6: Display

    E200PS Operation Manual Function Description Start key: automatic start-up, top left corner of the key is operation indicator LED. When operation is started, this indicator LED is on. Stop key: stop operation, top left corner of the key is Stop indicator LED. When initialize normal start-up and no operation, this indicator LED is on.
  • Page 7: Chapter 2 Operation Example

    According to the actual situation to set. 2.1.3 Procedure Step 1 When the E200PS device is electrified, wait a few seconds into the SINGLE page (Default page). Step 2 According to the analysis, press the arrow keys and number keys to modify the corresponding parameters, as shown in Figure 2-1.
  • Page 8: Multi-Step

    1.00mm 3 / 3ST 5.00mm Repeat Times 2.2.3 Procedure Step 1 When the E200PS device is electrified, wait a few seconds into the SINGLE page (Default page). Step 2 Press to enter PROGRAMS page. Step 3 Press or arrow key to select 2program, and then press to enter the NO.2 PROGRAM page.
  • Page 9 E200PS Operation Manual NO.2 PROGRAM 10.00 G = 10.00 3 STEP 5 PIECE 5 PIECE :Total Step Figure 2-2 Multi-Step example configuration Step 5 Press to enter 1/3ST page, and modify the parameters according to Step4, the result of modifying is as shown in Figure 2-3.
  • Page 10: Chapter 3 Operation Description

    E200PS Operation Manual Chapter 3 Operation Description 3.1 Tipwizard 3.1.1 Start and Stop  After finishing the programming, press to run the device.  The device starts, the green indicator light.  Only on the SINGLE page, PROAGRAM page or STEP page, the machine can run after pressing .
  • Page 11: Operation Flow

    E200PS Operation Manual 3.2 Operation Flow Power Press Press Single-Step Manual Single Run Press Press Press Programs Mutil-Step Mutil-Step Run Press Press Press Press Press Press ALARM CONST IO MONITOR RECORD Press Press Press Password: 5656 Password: 1212 Password: 14789...
  • Page 12: Single Step

    Because of the SINGLE page has simple and direct parameter, it more suitable for the shearing operation just only one-step. When the E200PS device is electrified, wait a few seconds into the SINGLE page (Default page), as shown in Figure 3-2.
  • Page 13: Multi-Step

    In the actual processing, operator user pedal switch to control the shearing process. In PROGRAM page, you can finish the complex operation with carefully programmed. Step 1 When the E200PS device is electrified, wait a few seconds into the SINGLE page (Default page). Step 2 Press to enter the PROGRAMS page, as shown in Figure 3-3.
  • Page 14 E200PS Operation Manual The description of the PROGRAM parameters is as shown in Table 3-2. Table 3-2 The description of the PROGRAM parameters Parameter Default Range Unit Description 0~25 The total number of steps in this program. The number of processing workpiece in this 0~99999 program.
  • Page 15: Manual

    In general, operator wants to adjust the backgauge or the block, need to enter MANUAL page to do relevant operation. When the E200PS device is electrified, wait a few seconds into the SINGLE page (Default page), press enter MANUAL page, as shown in Figure 3-6.
  • Page 16: Alarm And Monitor

    E200PS Operation Manual 3.6 Alarm and Monitor  On the CONST page, press to enter IO MONITOR page, as shown in Figure 3-7. IO MONITOR INPUTS 01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10...
  • Page 17: Appendix A Common Fault And Troubleshooting

    E200PS Operation Manual Appendix A Common fault and troubleshooting Fault phenomena Trouble shooting  When power on, the device will not The electrode of power supply terminal is connected display. error; please see the information of power nameplate.  Voltage is too low.
  • Page 18: Appendix B Alarm List

    E200PS Operation Manual Appendix B Alarm List Alarm NO. Alarm Information Alarm Description Normal message, that the count reaches a preset A.01 Pieces reached value. The current position of X-axis is out of the minimum A.02 XPos < minimum value, it is necessary to move the X-axis to the soft limit range manually.
  • Page 19: Appendix C Parameter Description

    E200PS Operation Manual Appendix C Parameter Description Parameter Default Range Unit Description CONST  0: mm mm/inch  1: inch 0: 中文  中文/English  1: English The current software version Version number. TchIn PARA When the teaching of X-axis is enabling, the operator X-tea.
  • Page 20 E200PS Operation Manual Parameter Default Range Unit Description  PP=0: this value is the current work piece. 0~99999  PP>0: this value is the remain work piece. STEP -9999.999~999 0.00 mm/inch Program position of X-axis. 9.999 0.00 0~99.99 mm/inch Program position of G-axis.

Table of Contents