Download Print this page

GE Cafe Series Manual page 54

Dual cavity gas, free standing ranges

Advertisement

Self Clean Sequence of Operation
When the lower oven is placed into clean mode,
1. The gas lockout valve rotates to shut off the cooktop gas, returns signal to ERC.
2. The lower oven latch locks the door , returns signal to ERC.
3. The upper oven latch locks the door , returns signal to ERC.
4. The upper oven lockout relay is activated , returns signal to ERC.
5. The cooling fan is turned on. (Café models)
Clean time can be set from 3 to 5 hours, default is 4 hours.
When the cycle is complete,
1. The lower oven unlocks , returns signal to ERC.
2. The upper oven unlocks , returns signal to ERC.
3. The gas lockout rotates to allow gas flow to the cooktop , returns signal to ERC.
The upper oven follows the same sequence, the cycle time is fixed at 5 hours.
The spark module remains active but the burners will not light during clean.
Note: if any of these sequences fail; the ovens will NOT self clean.