eWON FLX 3401 Installation Manual

8di-4ai-2do extension card

Advertisement

eWON
Installation Guide
IG 018 / Rev 1.1
This installation guide explains how to install the eWON Flexy
8DI-4AI-2DO Extension Card FLX 3401.
This installation guide explains how to install the eWON Flexy 8DI-
4AI-2DO Extension Card FLX 3401.
eWON Flexy
8DI-4AI-2DO Extension Card
FLX 3401
Installation Guide
Subject to change without notice.
Check
http://wiki.ewon.biz
for the last document release.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLX 3401 and is the answer not in the manual?

Questions and answers

Summary of Contents for eWON FLX 3401

  • Page 1 FLX 3401 Installation Guide This installation guide explains how to install the eWON Flexy 8DI-4AI-2DO Extension Card FLX 3401. This installation guide explains how to install the eWON Flexy 8DI- 4AI-2DO Extension Card FLX 3401. Subject to change without notice. Check http://wiki.ewon.biz...
  • Page 2: Table Of Contents

    Cards..............19 5. Check Card Detection on the Embedded Web Page..............20 5.1 Connecting to the Embedded Web Server................20 5.2 Detected Cards Displayed in the System Page.................20 Revision history............................. eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 2/21...
  • Page 3: Introduction

    FLX 3401 of the eWON Flexy family. The eWON Flexy family is a range of modular industrial gateway/router. As the name eWON Flexy suggests, it has been designed to enable numerous different combinations of Extension Cards and Base Units. The present Installation Guide is focusing on an extension card which, as such, needs to be inserted in one of the Base Units in order to work.
  • Page 4: Safety, Environmental & Regulatory Information

    2. Safety, Environmental & Regulatory Information Scope The present section addresses Safety, Environmental & Regulatory Information for the 8DI-4AI- 2DO Extension Card FLX 3401. This Extension Card is basically belonging to the same compliance frame than the Base Units. ESD Damage Prevention Caution! ontains parts and assemblies susceptible to damage by electrostatic discharge (ESD).
  • Page 5: Fcc Compliance

    UL declaration of conformity (DOC) # E350576 ● CB certificate # DK-29479-M1-UL ● These certificates can be downloaded as PDF files on the eWON Support web site: http://wiki.ewon.biz/Support/07_Documentations/Official_documents eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 5/21...
  • Page 6: Hardware Description

    Chapter 3. Hardware Description 3. Hardware Description Mechanical Layout and Interfaces IO mating connector 18 screw terminals Back-plane connector eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 6/21...
  • Page 7: Extension Card Label

    1111-2233-0001-44 1111 = MTID (product related) 2233 = Year Week 0001 = sequential mfg order = product type CE, UL,... certificate number and Marks logos if applicable. eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 7/21...
  • Page 8: Part Number Structure For Extension Cards

    1 is closed ON Green REL2 when relay 2 is closed (*) Two simultaneous status changes on different DI will result in no LED status change. eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 8/21...
  • Page 9: Io Specifications

    (*) Terminal numbers R11, R14, R22 and R24 are derived from 11 (Common) and 14 (NO) that refer to the Single Pole, Single Throw, Normally Open (SPST NO) relay terminal numbering as per standard EN 50005. eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 9/21...
  • Page 10: Typical Wiring Diagram

    Chapter 3. Hardware Description 3.4.2 Typical Wiring Diagram eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 10/21...
  • Page 11: Analog Inputs (4)

    4 (2 independent outputs) Relay type Single Pole, Single Throw, Normally Open = SPST NO Input voltage max. 24 VDC/VAC Max. current (ext. source) Functional Isolation 1,5 kV eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 11/21...
  • Page 12: Ewon Flexy Extension Cards Environmental Conditions

    -25 to +70 °C Storage temperature -40 to +70 °C Relative humidity 10 to 95% non-condensing Operating altitude Up to maximum 2000m Storage altitude Up to maximum 3000m eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 12/21...
  • Page 13: Plugging The Extension Card Into The Base Unit

    3.6.1 Base Unit Slot Compatibility The 8DI-4AI-2DO Extension Card (FLX 3401) can be inserted in all slots of the Base Unit. Explanation: The Flexy Base Units feature two type of slots. The A slots are the two first slots starting from the left.
  • Page 14: Extension Card Insertion

    Hooks to be pressed are off-centered – press while pulling upwards Insert the Extension Card carefully and slide it down until the hooks are clicking. Make sure the card is completely inserted. eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 14/21...
  • Page 15: Multiple 8Di-4Ai-2Do Extension Cards

    Cards. This detection is done sequentially, slot per slot starting from the left to right. The Extension Cards of type FLX 3401 can be inserted in all slots. The eWON Flexy firmware supports up to 4 Extension Cards of this type.
  • Page 16 Slot number append to prevent tag address mismatch: Let's take the example of an eWON Flexy featuring 2 IO cards FLX 3401 in slots #2 and #4 as shown in the picture above. The tag address for the eWON IO server can be extended as follows:...
  • Page 17: Power Requirements

    3.6.5 Power Requirements The internal power converter of the eWON Flexy Base units has been dimensioned to cover a broad range of different combinations of Extension Cards. Users should make sure the total power demand of the Extension Cards does not exceed the capabilities of the Base Unit. That is why the notion of “Energy Points”...
  • Page 18: Powering On The Base Unit With Its Extension Cards

    If the boot process completes normally, you should observe the following LED status Base Unit flashing green slowly Extension Card flashing green (acquisition running) eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 18/21...
  • Page 19: Check Card Detection On The Embedded Web Page

    Unit is: Diagnostic (1) > Status (2) > System Info (3) > System (4). The screen capture below gives an example of an FLX 3401 extension card that has been detected in slot 1 (5). eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide)
  • Page 20 Chapter 5. Check Card Detection on the Embedded Web Page eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 20/21...
  • Page 21: Revision History

    No part of this handbook can be reproduced, transmitted or copied in any way without written consent from the manufacturer and/or the authors of this handbook eWON sa, Member of ACT'L Group. eWON Flexy - 8DI-4AI-2DO Extension Card - FLX 3401 (Installation Guide) Page 21/21...