How To Use The PARI Filter Set 
 
Intended Use:
 
The PARI Filter Set is to be used when inhaling nebulised 
antibiotics.  It prevents contamination of the environment by 
the patient's exhaled air.  The PARI Filter Set should be used for 
inhalation therapy of any medication which may be hazardous 
to health if inhaled constantly.  Due consideration for the use 
of the PARI Filter Set should be given by nursing staff in the 
hospital or a parent assisting their child when nebulising 
antibiotics.  It also helps prevent antibiotic resistance.  
Please note; this information sheet does not replace the instructions for use.  
Please ensure you read the Instructions for Use for both the eFlow® rapid and PARI 
Filter/Valve Set. 
How to Assemble to LC PLUS/LC SPRINT  
1) Place a filter pad (2) in the exhalation filter upper part (1b). 
2) Insert the exhalation filter lower part (1a) in the exhalation filter upper part with the 
snap locks in the holes provided. 
3) Close the exhalation filter by turning its lower part clockwise as far as it will go. 
4) Insert the Y‐connection (3) in the exhalation filter and on the nebuliser (5a). 
5) Insert the mouthpiece without the expiratory valve (4) or BABY mask (6) onto the free 
end of the Y‐connection.  
6) Connect the inspiratory valve (7) to the LC Plus. 
a) This part is not necessary if you are using an LC Sprint.  
 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pari and is the answer not in the manual?

Questions and answers

Summary of Contents for Technipro-PulmoMed Pari

  • Page 1   How To Use The PARI Filter Set    Intended Use:   The PARI Filter Set is to be used when inhaling nebulised  antibiotics.  It prevents contamination of the environment by  the patient’s exhaled air.  The PARI Filter Set should be used for  inhalation therapy of any medication which may be hazardous  to health if inhaled constantly.  Due consideration for the use  of the PARI Filter Set should be given by nursing staff in the  hospital or a parent assisting their child when nebulising  antibiotics.  It also helps prevent antibiotic resistance.   Please note; this information sheet does not replace the instructions for use.   Please ensure you read the Instructions for Use for both the eFlow® rapid and PARI  Filter/Valve Set.  How to Assemble to LC PLUS/LC SPRINT   1) Place a filter pad (2) in the exhalation filter upper part (1b).  2) Insert the exhalation filter lower part (1a) in the exhalation filter upper part with the  snap locks in the holes provided.  3) Close the exhalation filter by turning its lower part clockwise as far as it will go.  4) Insert the Y‐connection (3) in the exhalation filter and on the nebuliser (5a).  5) Insert the mouthpiece without the expiratory valve (4) or BABY mask (6) onto the free  end of the Y‐connection.   6) Connect the inspiratory valve (7) to the LC Plus.  a) This part is not necessary if you are using an LC Sprint.      ...
  • Page 2 How to use with an eFlow® rapid  1) Place a filter pad (2) in the exhalation filter upper part (1b).  2) Insert the exhalation filter lower part (1a) in the exhalation filter upper part with the  snap locks in the holes provided.  3) Close the exhalation filter by turning its lower part clockwise as far as it will go.  4) Insert the Y‐connection (3) in the exhalation filter and on the eFlow rapid Aerosol  chamber.  5) Insert the mouthpiece without the expiratory valve (4) or smart mask onto the free end  of the Y‐connection.        ...
  • Page 3 Cleaning your Filter Set  The PARI Filter Set must be cleaned, disinfected and sterilised after each use.  To clean the  Filter Set:‐  1) Dismantle all parts of the PARI  Filter Set  2) Wash in warm water for 5 minutes with a little dishwashing liquid.  a) OR, wash in the dishwasher placing parts in cutlery basket  3) Drain off well.  Disinfection  1) Place all individual parts in boiling water for 15 minutes.  If local water is hard – use  distilled water.   2) Do not let boil dry.  3) It is also possible to disinfect in a baby bottle steam steriliser. E.g. NUK Vaporiser 6 ...

Table of Contents