Description 
 
 
Features 
 
Application 
 
Components 
 
 
TS‐3D... series three phase enclosures are suited for any Deaerator, 
Surge, Condensate, or Combination DA/SRG, DA/Condensate, or 
Surge/Condensate stand‐alone 480VAC panels. Provide a single 
point power entry and connects to SCC Inc. control system. 
  
The TS‐3D... three phase enclosures are suited for DA, Surge, or 
condensate for feedwater or transfer pump motor controls with 
starters or VFDs. 
 Up to 6 pumps  
 Up to 50HP feedwater pump motor starter or VFD protected 
connection, up to 20HP compressor motor starter, and up to 
10HP for the oil pumps motor starter 
 120VAC fused power connection 
 Control panel command and feedback connections 
 NEMA12/4X 
 UL 508 listed
 
 
 
The TS‐3D... three phase enclosures are suited for DA, 
Surge, Condensate, or combination with 480VAC 
 
TS... 3 phase panel may include the following components: 
Technical Instructions
 
Document No. TS‐3500 
 
 
 
 
 
 
January 11, 2019
 
SCC Inc. 
 
 
 

Advertisement

loading
Need help?

Need help?

Do you have a question about the TS-3D Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SCC TS-3D Series

  • Page 1 SCC Inc. Technical Instructions         Document No. TS‐3500      January 11, 2019         TS‐3D…. Stand‐Alone Deaerator/Surge or Condensate Tanks Three  Phase Enclosures                                                                                                                                                                                                                                                                        Description  TS‐3D… series three phase enclosures are suited for any Deaerator,  Surge, Condensate, or Combination DA/SRG, DA/Condensate, or  Surge/Condensate stand‐alone 480VAC panels. Provide a single  point power entry and connects to SCC Inc. control system.     The TS‐3D… three phase enclosures are suited for DA, Surge, or  condensate for feedwater or transfer pump motor controls with  starters or VFDs.       Up to 6 pumps   Features   Up to 50HP feedwater pump motor starter or VFD protected ...
  • Page 2  Starters control and feedback current switch terminals   Power indication light                                                                  Page 2      SCC Inc.  ...
  • Page 3: Product Part Numbers

    Enclosure and NEMA rating (Steel, powder coated enclosures)           S = NEMA12/4X no cooling fan, no VFDs installed in enclosure           1 = NEMA1 with cooling fan, drives shipped loose or by others           2 = NEMA12 with cooling fan includes hood over fan, drives shipped loose or by others           4 = NEMA4X with cooling fan includes hood over fan, drives shipped loose or by others            A = NEMA1 with cooling fan, Yaskawa drives installed in enclosure (Future, contact SCC)            B = NEMA12 with cooling fan includes hood over fan, Yaskawa drives installed in enclosure (Future, contact SCC)        C = NEMA4X with cooling fan includes hood over fan, Yaskawa drives installed in enclosure (Future, contact SCC)                          Pump Run Indicator Lights        Y = Included in enclosure ...
  • Page 4: Specifications

    Voltage    Power Consumption    HP Dependent      SCCR (Short Circuit Current Rating)  200KA RMS                Operating environment  Operating Temperature  ‐10 to 131 °F  [‐23 to 55 °C]      Humidity  Max. 85% with no  condensation                        Page 4      SCC Inc.  ...
  • Page 5: Field Connections

    TS Series    Technical Instructions    Document No. TS‐3500    Field Connections    Three Phase Disconnect Switch and Motor Connections with Starter Control         SCC Inc.    Page 5  ...
  • Page 6 Technical Instructions    TS Series  Document No. TS‐3500  Field Connections (continued)    Three Phase Disconnect Switch and Motor Connections with Variable Speed Drive       Page 6      SCC Inc.  ...
  • Page 7 TS Series    Technical Instructions    Document No. TS‐3500    Field Connections (continued)    Connections with SCC Deaerator/Surge/Condensate Control Panel and with Starter Control                     SCC Inc.    Page 7  ...
  • Page 8 Technical Instructions    TS Series  Document No. TS‐3500  Field Connections (continued)    Connections with SCC Deaerator/Surge/Condensate Control Panel and with VSD                     Page 8      SCC Inc.  ...
  • Page 9: Parts Description

    5‐ Pump status current switches  9‐ Pump on indication lights                    VFD Control                 1‐ Main Fused Disconnect with locking handle  5‐ Feedwater pump fused VFD connection  2‐ Three phase power distribution blocks  6‐ Feedwater pump fused VFD connection  3‐ 480VAC to 120VAC control transformer  7‐ Power indication light  4‐ 120VAC feed through and interconnecting  8‐ Main fused disconnect handle  terminals  9‐ Pump on indication lights          SCC Inc.    Page 9  ...
  • Page 10 100A  100A  Main disconnect fuse size (Amp)  30  40  50  70  80  Starter Upstream Fuse Holder (Amp)  N/A  N/A  N/A  N/A  N/A  Enclosure Size  24"X24"X10"  24"X24"X10"  24"X24"X10"  24"X24"X10"  24"X24"X10"  Wire AWG from Disconnect to Distribution  TS‐W‐6  TS‐W‐6  TS‐W‐6  TS‐W‐6  TS‐W‐4  Wire AWG Distribution to Fuse Holders  TS‐W‐10  TS‐W‐10  TS‐W‐10  TS‐W‐10  TS‐W‐10           Page 10      SCC Inc.  ...
  • Page 11 400A  Main disconnect fuse size (Amp)  90  125  150  200  225  Starter Upstream Fuse Holder (Amp)  60  60  60  60  60  Enclosure Size  40"X32"X10"  40"X40"X12"  40"X40"X12"  47"X40"X12"  47"X40"X12"  Wire AWG from Disconnect to Distribution  TS‐W‐1/0  TS‐W‐2/0  TS‐W‐2/0  TS‐W‐3/0  TS‐W‐4/0  Wire AWG Distribution to Fuse Holders  TS‐W‐4  TS‐W‐4  TS‐W‐4  TS‐W‐4  TS‐W‐4             SCC Inc.    Page 11  ...
  • Page 12 300  400  N/A  Starter Upstream Fuse Holder (Amp)  100  100  100  100  N/A  Enclosure Size  40"X32"X10"  47"X40"X12"  47"X40"X12"  47"X40"X12"  N/A  Wire AWG from Disconnect to Distribution  TS‐W‐2/0  TS‐W‐3/0  TS‐W‐4/0  TS‐W‐350Kcmil  N/A  Wire AWG Distribution to Fuse Holders  TS‐W‐1/0  TS‐W‐1/0  TS‐W‐1/0  TS‐W‐1/0  N/A                    Page 12      SCC Inc.  ...
  • Page 13 100A  Main disconnect fuse size (Amp)  35  50  65  80  90  VSD Fuse holder (Amp)  30  30  30  30  30  Enclosure Size  24"X24"X10"  24"X24"X10"  24"X24"X10"  24"X24"X10"  24"X24"X10"  Wire AWG From Disconnect to Distribution  TS‐W‐6  TS‐W‐6  TS‐W‐6  TS‐W‐6  TS‐W‐4  Wire AWG From Distribution to Fuse Holders  TS‐W‐10  TS‐W‐10  TS‐W‐10  TS‐W‐10  TS‐W‐10             SCC Inc.    Page 13  ...
  • Page 14 400A  400A  Main disconnect fuse size (Amp)  120  165  200  250  300  VSD Fuse holder (Amp)  100  100  100  100  100  Enclosure Size  40"X40"X12"  40"X40"X12"  40"X40"X12"  47"X40"X12"  47"X40"X12"  Wire AWG From Disconnect to Distribution  TS‐W‐1/0  TS‐W‐2/0  TS‐W‐2/0  TS‐W‐3/0  TS‐W‐4/0  Wire AWG From Distribution to Fuse Holders  TS‐W‐4  TS‐W‐4  TS‐W‐4  TS‐W‐4  TS‐W‐4           Page 14      SCC Inc.  ...
  • Page 15 350  400  N/A  VSD Fuse holder (Amp)  200  200  200  200  N/A  Enclosure Size  40"X40"X12"  47"X40"X10"  47"X40"X12"  47"X40"X12"  N/A  Wire AWG From Disconnect to Distribution  TS‐W‐2/0  TS‐W‐3/0  TS‐W‐4/0  TS‐W‐350Kcmil  N/A  Wire AWG From Distribution to Fuse Holders  TS‐W‐1/0  TS‐W‐1/0  TS‐W‐1/0  TS‐W‐1/0  N/A                     SCC Inc.    Page 15  ...
  • Page 16 Technical Instructions    TS Series  Document No. TS‐3500  Dimensions  Dimensions in inches; millimeters in brackets  24” x 24” x 10” Combustion Enclosure                                      Page 16      SCC Inc.  ...
  • Page 17 TS Series    Technical Instructions    Document No. TS‐3500    Dimensions (continued)  Dimensions in inches; millimeters in brackets  32” x 32” x 10” Combustion Enclosure                          SCC Inc.    Page 17  ...
  • Page 18 Technical Instructions    TS Series  Document No. TS‐3500  Dimensions (continued)  Dimensions in inches; millimeters in brackets  40” x 32” x 10” Combustion Enclosure                                Page 18      SCC Inc.  ...
  • Page 19 TS Series    Technical Instructions    Document No. TS‐3500    Dimensions (continued)  Dimensions in inches; millimeters in brackets  40” x 40” x 12” Combustion Enclosure                            SCC Inc.    Page 19  ...
  • Page 20 Technical Instructions    TS Series  Document No. TS‐3500  Dimensions (continued)  Dimensions in inches; millimeters in brackets  47” x 40” x 12” Combustion Enclosure                      Information in this publication is based on current specifications.  The company reserves the right to make changes  in specifications and models as design improvements are introduced.  Product or company names mentioned  herein may be the trademarks of their respective owners.  © 2018 SCC Inc.    SCC Inc.  Your feedback is important to us.  If you have  Document No. TS‐3500 1250 Lunt Avenue  comments about this document, please send them  Country of Origin:  US  Elk Grove Village, IL  60007  to techsupport@scccombustion.com  Page 20    U.S.A.    ...