Advertisement

Quick Links

www.osram.asia
DEC
2015
Technical Application Guide
®
PrevaLED
SKY Module
Light is OSRAM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PrevaLED SKY and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Osram PrevaLED SKY

  • Page 1 2015 Technical Application Guide ® PrevaLED SKY Module Light is OSRAM...
  • Page 2: Table Of Contents

    LED modules and light engines 4.2 Photobiological safety Please note: All information in this guide has been prepared with great care. OSRAM, however, does not accept liability for possible errors, changes and/or omissions. Please check www.osram.com or contact your sales partner for an updated copy of this...
  • Page 3: Introduction

    - fully integrated IP66 module with optical and heat sink as less than 400g. Additional details on optical, thermal, mechanical and electrical characteristics can be found in the following sections. Further and updated information (IES files, CAD files and updates of this guide) will be posted at www.osram.com.
  • Page 4: System Information

    ® Technical Application Guide | PrevaLED SKY Module Introduction ® PrevaLED SKY: Two power packages Parameter Electrical Power @700mA (typical) Flux [lm] 6000 6000 3000 3000 CCT [K] 6500 4000 6500 4000 Light Output Light Distribution / x 60 , 100 x 100 , 100 x 60...
  • Page 5: Nomenclature And Marking

    ® Technical Application Guide | PrevaLED SKY Module Introduction 1.2.1. Nomenclature and marking ® The PrevaLED product series follows a consistent naming convention for identifying key parameters of the LED module and the LED power supply. LED Module Product Family ®...
  • Page 6 ® Technical Application Guide | PrevaLED SKY Module Introduction LED power supply: OSRAM Outdoor ECG On/OFF Product Family ® OT: OPTOTRONIC Wattage: Input voltage: 120-277V AC Max output current 700mA IP rating: IP65 OT 50/120…277/700 P5 LED power supply: OSRAM Outdoor ECG 2DIM Product Family ®...
  • Page 7: Technical Data

    The data above is for reference only. Please contact Osram sales or marketing staff for advice if customers has any specific demand on particular parameters. Ranking at Ta = 25°.Tolerance of measurements for the colour rendering Ra is ±2.
  • Page 8 ® Technical Application Guide | PrevaLED SKY Module Introduction Nominal Outdoor Output Lifetime L90 output Typ. Tc max. Current at Tc point power Efficiency [mA] On/OFF OT 50/120-277/700 P5 17-50 80000 at Tc=70 OT 100/120-277/700 P5 50-100 80000 at Tc=75 -40 to +55 80000 at Tc=80 OT 180/120-277/700 P5...
  • Page 9: Possible System Combinations

    ® Technical Application Guide | PrevaLED SKY Module Introduction 1.2.3. Possible system combinations ® ® Within rated power and voltage range, PrevaLED SKY modules and OPTOTRONIC power supplies can be flexibly combined. Valid and possible combinations of LED modules and ECGs are shown in the table below.
  • Page 10: Luminaire Design

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design 2. Luminaire Design 2.1. Optical considerations 2.1.1. Quality of light ® The PrevaLED SKY optical design has three light-emitting zone consisting of optical lens and high power LEDs, as shown in the image above. ®...
  • Page 11: Cri, Cct

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design 2.1.2. CRI, CCT The nominal available correlated color temperatures (CCT) of LED modules are 4000K and 6500K. The color rendering Index (CRI) is >70 for all LED modules. ® ® Color bin of PrevaLED SKY modules with CCT:4000K Color bin of PrevaLED...
  • Page 12: Led Power Supply And Cable Dimensions

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design 2.2.2. LED power supply and cable dimensions - OT outdoor On/Off 700mA IP65 Driver OT 50/120-277/700 P5 OT 100/120-277/700 P5 OT 180/120-277/700 P5 OT 250/120-277/700 P5 Cable dimensions of driver Value Item Unit...
  • Page 13: Ot Outdoor 2Dim Ip64 Driver

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design LED power supply dimensions - OT outdoor 2DIMmA IP64 Driver Driver dimensions OT 50/120-277/800 2DIMLT2 P OT 100/120-277/800 2DIMLT2 P OT 50/120-277/1A2 2DIMLT2 P OT 110/120-277/1A4 2DIMLT2 P Cable dimensions of driver Value Item Unit...
  • Page 14: Thermal Considerations

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design 2.3. Thermal considerations ® The PrevaLED SKY LED module has integrated heat sink providing optimal thermal management. Customer do not need to install extra heat sink for the SKY LED module. ®...
  • Page 15: Over Temperature Protection - Otp

    Temperature Coefficient Thermistor) sticking on the Tc point of PrevaLED SKY module to realize the over temperature protection function. Customer need to program the parameter of NTC into OT 2DIM LED driver via device of ‘OSRAM OT Programmer’ and the software “Tuner4TRONIC ”. See below graph.
  • Page 16: Wiring Information

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design 2.4.2. Wiring information ® The PrevaLED SKY LED module provide 2 type of input wire: - Input wire with tin plated at the end of wire (a) - Input wire with M15 waterproof connector (b) For the type ‘a’...
  • Page 17 ® Technical Application Guide | PrevaLED SKY Module Luminaire Design ® System wiring between OT outdoor On/Off driver and PrevaLED OT 50/120-277/700 P5 OT 180/120-277/700 P5 ® PrevaLED ® PrevaLED LED Driver LED Driver LED+ LED- (red) (black) LED+ LED- (red) (black) +(brown)
  • Page 18: Electrostatic Discharge (Esd)

    ® Technical Application Guide | PrevaLED SKY Module Luminaire Design 2.4.3. Electrostatic discharge (ESD) To protect the light engine from electrostatic damage, the module must not be opened. The light engine fulfills the requirement of the immunity standard IEC/EN 61547. ESD Protection: contact 4kV and air 8kV.
  • Page 19: Installation Guide

    ® Technical Application Guide | PrevaLED SKY Module Installation Guide 3. Installation Guide Note: The installation of LED systems (LED modules and ECGs) needs to be carried out in compliance with all applicable electrical and safety standards. Only qualified personnel should perform installations. 3.1.
  • Page 20: Installation Of More Than One Led Module Inside A Luminaire

    ® Technical Application Guide | PrevaLED SKY Module Installation Guide 3.2.2. Installation of more than one LED module inside a luminaire Road orientation Pole position 3.3 LED module application and mounting layout a) 150º x 80º T40º Transverse (80 Tilting (40 Staggered or Opposite 6000 lm 3000 lm...
  • Page 21 ® Technical Application Guide | PrevaLED SKY Module Installation Guide c) 150º x 80º T40º 150º x 80º T40º Need combine two optics in one luminaire Single Side mounting d) 100º x 60º Transverse (100 Asymmetric (Floodlight) 6000 lm 3000 lm e) 60º...
  • Page 22: Application Of Mechanical Installation

    ® Technical Application Guide | PrevaLED SKY Module Installation Guide 3.4. Application of mechanical installation Please keep the module lens clean. Any stains or mechanical damage will affect the optical performance of LED module. Suggested min. clearance distance between modules Please do not remove the plastic >10mm.
  • Page 23: Norms And Standards

    ® Technical Application Guide | PrevaLED SKY Module Norms and Standards 4. Norms and standards ® 4.1. Norms and standards for PrevaLED LED modules and light engines IP Rating IP66 Standard IEC 62471; EN 60529; EN 62031;IEC 60598-1; EN 55015; EN 61547 Flammability IEC 60598-1 Environment...
  • Page 24 OSRAM Asia Pacific Management Company China office: Sales and Technical Support 5/F, Hantang Building, Overseas Chinese Town, Shennan Ave, Nan Shan District, 518053, Shenzhen, Guangdong, P.R. China...

Table of Contents