EVO 1000 User's Guide
O
and CO
In-Line Dosing Unit
2
2

Advertisement

Table of Contents
loading

Summary of Contents for Parsec Srl EVO 1000

  • Page 1 EVO 1000 User’s Guide and CO In-Line Dosing Unit...
  • Page 2 A regulator for the CO or N Always use CO , in its gaseous phase (from the top) and have an electric re-heater on hand. Gas tank connectors vary from country to country 2 / 19 EVO 1000 User’s Manual –Rev 2017...
  • Page 3 Check the canister model and type of attachment in your country Standard attachment types used in France for different gas FOR CO Never use the canister when making dry ice with the discharge horn 3 / 19 EVO 1000 User’s Manual –Rev 2017...
  • Page 4: Table Of Contents

    Table of Contents 1. Product description: 2. Installation ________________________________________ How to install the EVO 1000: ___________________________ Connecting the EVO1000 ______________________________ 3. Programming the EVO 1000 __________________________ PRESS F3 FOR INFORMATION ___________________________ Cleaning Procedure: __________________________________ DOSAGE MODE: _____________________________________ 4. OENOLOGICAL USES _________________________________...
  • Page 5: Product Description

    2. I NSTALLATION A. How to install the EVO 1000: ✓ Assemble the stainless-steel chassis according to the picture. ✓ Attach the dosage box to the frame with the 4 screws at the back of the cabinet.
  • Page 6: Connecting The Evo1000

    ✓ Then connect the regulator to the re-heater. Unscrew the pressure adjustment knob as much as possible (counter-clockwise). ✓ Use the hose to connect the regulator to the EVO 1000 INPUT. ✓ Avoid bends and protect the high-pressure line. ✓ Connect the re-heater to the splicer and open the canister.
  • Page 7: Press F3 For Information

    [F3] to start the dosing. The EVO 1000 should be control by a dry contact (from bottling line or filter) when it is working in-line on a filtration process or bottling. (See cable connection diagram on page 27) In that case, the “Status”...
  • Page 8: Cleaning Procedure

    Case of fixed installation: The EVO 1000 is a device that can be used on-line at fixed stations, usually between the filter and a bottling machine. The cleaning procedures adopted throughout the wine pass line can be applied to the EVO1000 and its accessories (probes, flowmeter, etc.).
  • Page 9 - Add a dose of citric acid to have 0.5% concentration on the volume of the tank. - Homogenize, check pH (<3). - Switch on the rotor pump and the EVO 1000 as before. Let it rotate for 3 to 5 minutes, then empty the tank in the sewer. (Check pH) Caution: the mixture of alkaline products with acid products causes an exothermic reaction.
  • Page 10: Dosage Mode

    The initial flow rate can be verified in “PARAMETER SETTING” mode (see below). The flow meter takes 10 seconds to stabilize the amount and communicate with the EVO 1000. Before then, the flow rate shown is the one that is indicated during programming.
  • Page 11: Oenological Uses

    A. AUTOMATIC DEOXYGENATION The stainless steel DO 225 PARSEC probe measures dissolved O directly as it passes through the line. The probe’s cord should be connected to the EVO 1000. In-Line Deoxygenation (DO probe downstream) ASSEMBLY DIAGRAM AUTO COMPENSATION MODE Comp.: (YES) automatically adjusts the nitrogen dose according to...
  • Page 12: In-Line Deoxygenation During Bottling

    CO saturated wines), which saves gas and prevents you from decarbonizing wines. Deoxygenizing with the EVO 1000 prevents oxidation and losses of free SO , which in turn helps preserve wine’s freshness, complexity, and identifying characteristics. When deoxygenating, it is always better to treat the wine in a closed circuit as early as possible. This gives a better yield by mixing the treated wine with the surface wine.
  • Page 13: Carbonication Of White And Rosé Wines

    To add gas over 1 g/l during bottling, use pressurized equipment like ISO barometric bottling line. PARSEC provides a carbodoser with the EVO 1000 to gauge dissolved CO levels in wine. This simple and fragile...
  • Page 14: Adjusting Co 2 - Still Wines (3°C < Temp. < 15°C)

    ✓ 2.300 mg/l (Ex: Perlé de Gaillac - France). EVO 1000 can be used in the 3 situations described below. It is better to have a slight over-pressure at the output to help with gas solubilization. That is why PARSEC has designed a discharge valve that can adjust the necessary back pressure needed to effectively dissolve the CO injected during treatment.
  • Page 15: Gasification For Sparkling Wines

    Eye and ear protection is also recommended. Once the desired pressure has been set up, start the EVO 1000 by programming the dose to be injected. For in- line use, work with about 8 bars of power and a slow flow rate.
  • Page 16: Wine Decarbonication

    At the beginning of treatment, it is possible to fill the tank from the bottom. In that case, the hose must go in through the top of the tank and pull it up gradually. 16 / 19 EVO 1000 User’s Manual –Rev 2017...
  • Page 17: Cabling Diagram

    The square connector is the external source for the EVO 1000, to: ✓ Launch an automatic washing cycle ✓ Instantly stop the dosage (filter or drawer) The EVO 1000 sends and receives dry contacts. The hook-up instructions are as follows: EVO 1000 Connector DOS: Dosage...
  • Page 18 Comparative Chart for the 2 Different Versions of the EVO 1000 Single Double EVO1000 EVO1000 Wine CO2 dosage dosage Flow (g/l) (g/l) Hl/h 6.00 12.00 6.00 12.00 6.00 12.00 4.50 9.00 3.60 7.20 3.00 6.00 2.57 5.14 2.25 4.50 2.00 4.00...
  • Page 19: Certificate Of Compliance

    Model: 2012 Year built: The manufacturer hereby declares and guarantees that the above-mentioned machine complies with all of the specifications mentioned in directive EN 60439-3. EN 55022; EN50082-1; EN61000; EN 61000-3-3. 19 / 19 EVO 1000 User’s Manual –Rev 2017...