Download Print this page
Hide thumbs Also See for E.SYLINK:

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
Automated Environmental Systems Ltd
Unit 1, 1 Wimbledon Avenue, Brandon, IP27 0NZ
01842 819130
sales@automatedenvironmentalsystems.co.uk
www.automatedenvironmentalsystems.co.uk
Manual valid for firmware versions 1.x

Advertisement

loading

Summary of Contents for DAB E.SYLINK

  • Page 1 INSTALLATION INSTRUCTIONS Automated Environmental Systems Ltd Unit 1, 1 Wimbledon Avenue, Brandon, IP27 0NZ 01842 819130 sales@automatedenvironmentalsystems.co.uk www.automatedenvironmentalsystems.co.uk Manual valid for firmware versions 1.x...
  • Page 2: Installation

    Everything must be done in a workmanlike manner. Failure to respect the safety regulations not only causes risk e.sylink is the DAB accessory with wireless interface 802.15.4, de- to personal safety and damage to the equipment, but invali- signed to allow the e.sybox to use digital inputs (pressure switch, float, dates every right to assistance under guarantee.
  • Page 3: Digital Inputs

    ENGLISH 1.1 Technical Data The e.sylink has 4 optoinsulated digital inputs (connector J3), 2 NO (normally open) relay outputs (connector J15) and has an output for 1 remote pressure sensor (J31). There are 10 leds for the user interface Supply voltage 24 V ±...
  • Page 4: Output Contacts

    ENGLISH Output contacts: Input wiring The connections of the outputs listed below refer to the 9-pole terminal board (J15), indicated with screen printing O1, O2 and CA. Input connected to clean contact Voltage input Table 3 describes the characteristics and limits of the output contacts. Input Clean contact between pins Jumper...
  • Page 5: Pressure Sensor

    For examples of practical applications that can be implemented on the e.sylink, refer to the e.sybox installation manual. Pressure sensor: e.sylink allows the use of 1 remote pressure sensor, directly on the 4-pole connector J31. For further information refer to the e.sybox installation manual.
  • Page 6 Table 4: leds characteristics On the e.sylink there are leds indicating the system operating status. Table 4 describes the meaning of each leds on the user interface: Table 5 described the possible faults that may be found by e.sylink Fault LED FAULT...
  • Page 7 It is now possible to update e.sybox with e.sylink, using the wireless To interrupt the procedure it is possible to press the left key on the e.sylink. interface 802.15.4. To do this the two devices do not need to be asso- In the event of a momentary disconnection from e.sybox, the blue...
  • Page 8 If the update has not been successful, the red Fault led will light up on the e.sylink. Table 1 describes the number of blinks of the e.sylink FAULT led in the case of errors and the actions to be taken.