Page 2
The device bears the CE label in accordance with the provisions of Medical Device Directive 93/42/EEC. THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93/42/EEC SELVAS Healthcare, Inc. 29, Gongdan 4-ro, Jillyang-eup, Gyeongsan-si, Gyeongsangbuk-do, 38470 Republic of Korea TEL: 82-53-856-0993, FAX: 82-53-856-0995 VITAKO Sp.
CONTENTS INTRODUCTION ······································································································· 5 1. INTENDED USE........................5 2. WORD DEFINITIONS........................ 5 3. CLASSIFICATION AND COMPLIANCE..................6 4. SAFETY PRECAUTIONS......................6 5. SAFETY SYMBOLS AND INFORMATION................11 6. Guidance for Electromagnetic compatibility(EMC) ..............13 ABOUT BODY COMPOSITION ······················································································18 TERM AND FUNCTION OF EACH PART ·········································································20 1.
Page 4
3. Measurement ······································································································ 44 1) Basic Analysis ·································································································· 44 2) Analysis Using a height meter ············································································· 48 3) Analysis Using Blood Pressure Monitor ································································· 49 STORAGE OF DATA USING USB MEMORY ··································································· 50 PRINTING ················································································································· 52 RESULT INTERPRETATION ························································································ 53 STORAGE &...
INTRODUCTION We highly appreciate that you chose our company’s product. You are kindly requested to be familiar with these directions before using this product and always keep it together with the product. In case you are not sure about any directions or problems arising while using the product, please contact our service center.
3. CLASSIFICATION AND COMPLIANCE 1) This device is classified as; - Class 1 type-BF against electric shock - Ordinary equipment without protection against ingress of water - Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of EN 60601-1: 2006(Basic safety and essential performance of Medical Electrical Equipment) 2) This device is complied with Class A for Noise-Emission, Level B for Noise-immunity, by standard of IEC 60601-1-2:2007(Electromagnetic Compatibility Requirements).
Page 7
Caution If you have experienced any trouble with the unit, switch it off immediately, and contact our company or its authorized dealer for assistance. If you plan to connect any device from other manufacturers electrically or Caution mechanically to the unit, contact our company or its authorized dealer for instructions before doing so.
Page 8
Caution Cross contamination is possible because this equipment is used with bare hands and feet. Refer to the cleaning and disinfecting methods in this manual. Measurements may be impaired if this device is used near televisions, Caution microwave ovens, X-ray equipment or other devices with strong electrical fields.
Page 9
devices according to IEC 60601-1-2:2007. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity.
Page 10
This manual is made for informational purposes and this manual and product are not meant to be a substitute for the advice provided by your own physician or other medical expert. You should not use the information contained in the product for diagnosis or treatment of health problems or prescription of medication by yourself.
5. SAFETY SYMBOLS AND INFORMATION The International Electro-technical Commission (IEC) has established a set of symbols for medical electrical equipment which classify a connection or warning of any potential hazard. The classifications and symbols are shown below. Save these instructions for your safety. Degree of protection against electric shock: TYPE BF Please observe operating instructions General warning sign...
Page 12
This symbol is used inside system. Identifies the point where the safety ground of the system is fastened to the chassis. Do not open. This is for factory only. Alternating current Direct current Date of manufacture Manufacturer Non-ionizing radiation CE mark Serial No.
1) Guidance and manufacturer’s declaration – electromagnetic emissions The ACCUNIQ BC360 is intended for use in the electromagnetic environment specified below. The customer or the user of the ACCUNIQ BC360 should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
Page 14
2) Guidance and manufacturer’s declaration – electromagnetic immunity The ACCUNIQ BC360 is intended for use in the electromagnetic environment specified below. The customer or the user of the ACCUNIQ BC360 should assure that it is used in such an environment. IEC 60601 test...
Page 15
3) Guidance and manufacturer’s declaration – electromagnetic immunity 2 The ACCUNIQ BC360 is intended for use in the electromagnetic environment specified below. The customer or the user of the ACCUNIQ BC360 should assure that it is used in such an environment. 60601...
Page 16
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the ACCUNIQ BC360 is used exceeds the applicable RF compliance level above, the ACCUNIQ BC360 should be observed to verify normal operation.
Page 17
4) Recommended separation distances between portable and mobile RF communications equipment and the ACCUNIQ BC360 The ACCUNIQ BC360 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ACCUNIQ BC360 can help prevent...
ABOUT BODY COMPOSITION 1. Body Composition Human body consists of body fat and lean body. Lean body means non-fat constituents of human body like body water, muscles, mineral, etc. Body water is divided into intra- and extra-cellular water and the ratio between them is controlled and maintained within a certain range.
Page 19
5. Abdominal Fatness Body fat is divided into subcutaneous fat and visceral fat. Visceral obesity is considered to be a critical risk factor along with Percentage of body fat. Lipoprotein lipase can be easily activated in visceral fat, and it causes visceral fat to be dissolved easily.
TERM AND FUNCTION OF EACH PART 1. Basic Package The main system of ACCUNIQ BC360 consists of as follows. ① Main body ② User manual ③ Adapter ④ USB Cable ⑤ Data management program ⑥ Bolts ⑦ 5mm L-wrench ⑧ Body Cover ⑥...
2. Options 1) Ankle electrodes AE-202 Convenience: can measure with one's socks or stockings on. ① Selectivity: can choose either plate electrodes or ankle electrodes. ② Hygienic: protects from mold or bacteria ③ High accuracy: analyzes more accurately for the person whose sole is corneous 2) Professional health counseling support software This program helps managing body composition easily and...
Page 22
7) Bluetooth Bluetooth It allows to do wireless communicate with a PC or mobile device. 8) Height Meter Height meter This is an instrument to measure subject’s height more accurately and quickly. It employs standoff determination method using ultrasonic sensor. Note Measuring height in the morning is average 1~2cm higher than in the evening.
3. Appearance of the device 1) Front Part Color LCD Start button Handle Electrode ▪ Color LCD panel as touch screen. It displays the procedure and results. ▪ Handle Electrode Handle Electrode measure the impedance by sending harmless electric current to the body. Hold them with the hands during measurement.
Page 24
2) Rear Part Spare port (I) Height port Spare port (II) Blood Pressure port USB port (A) USB port (B) Adapter port Power switch ▪ Spare port(I): Connecting the peripheral devices(Bluetooth, etc.). ▪ Spare port(II): Connecting the peripheral devices. ▪ Height port: Connecting the height device. (OPTION) ▪...
Page 25
3) Base Part Plate electrode Weight scale ▪ Weight scale: It consists of four plate electrodes and it measures weight. ▪ Plate electrode: It measures the impedance. The user should step it in bare feet.
INSTALLATION 1. Power Supply Connect the power cable to the 'ADAPTER INPUT' placed on the lower back panel of the device. Connect the cable. Turn on the power switch placed next to Power input, then after moment initial screen animation is displayed automatically. 1.
2. Peripheral Device Installation 1) Connecting Computer Connect the “USB(B)” port placed on the rear panel of this device to the USB port in computer with USB cable. Or it can be connected through Bluetooth (option). Note 1. If use USB port, the cable should be connected to the computer port. 2.
2) Connecting Printer ① Connecting the device and the printer directly Connect A4 printer offered with this device to the “USB(A)” port placed on the rear panel of this device with USB cable. ② Connecting the device, computer, and the printer Connect a computer to the “USB(B)”...
3) Connecting Blood Pressure Monitor This device can be connected to the automatic blood pressure monitor of our company. (Option) Connect a blood pressure monitor to “BLOOD PRESSURE (RS-232C)” jack placed on the rear panel of the device with blood pressure monitor cable. 4) Connecting Ultrasonic Height meter Connect RS 232 cable to the 'HEIGHT ' port placed on the rear panel of the device.
5) Replacing of thermal paper (Option) Replace thermal paper while the power is on. ① Turn the screws counterclockwise and open the cover as shown in the picture. ② Insert the thermal paper to the direction as shown in the picture. ③...
SYSTEM SETUP ‘SYSTEM SETUP' allows the users to change the setting of operational parameters. Note For the purpose of improvement, the contents in SYSTEM SETUP can be changed. 1. Entering SYSTEM SETUP On the initial display, press ‘ ’ button on LCD for 3~5 second to enter System Set up. 2.
3. Selecting a Menu in SYSTEM SETUP Select menu according to one’s desire, and confirm changes using「SET」button. 4. Exiting SYSTEM SETUP Press 「CLOSE」button on 'SYSTEM SETUP' phase, then back to initial view of the analyzer. 5. Moving to SYSTEM SETUP Press「CLOSE」button on the menu view, then program is returned to 'SYSTEM SETUP' phase.
6. Setup < DATE / TIME > It sets date and time (year, month, day, hour, and minute). - Select (DATE / TIME) on SYSTEM SETUP screen and press SET button on touch pad. - Pre-set: The date of the device released from the manufacturer's factory.
Page 34
< PRINT > It selects the printing mode of the A4 printer. - Select (PRINT) on SYSTEM SETUP screen and press ‘SET’ button on touch pad. - Pre-set: AUTO - Choose one button on touch pad. - Press ‘SET’ button on touch pad to save it. - Return to SYSTEM SETUP screen by pressing ‘CLOSE’...
Page 35
< CLOTHES > It is to subtract the weight of clothes worn by the subjects from measured weight. Calculated value from this setting is used in body composition analysis as subject’s weight. - Select (CLOTHES) on SYSTEM SETUP screen and press ‘SET’ on touch pad. - Pre-set: 0.0 kg - Range: 0 ~ - 9.9 kg - Set the value with ‘▼, ▲’...
Page 36
< DATE TYPE > This is to set the format of the date. - Select (DATE TYPE) on SYSTEM SETUP screen and press ‘SET’ button on touch pad. - Pre-set: YY-MM-DD - Choose the format on touch pad. - Press ‘SET’ button on touch pad to save it. - Return to SYSTEM SETUP screen by pressing ‘CLOSE’...
Page 37
< ID usage > ID USAGE can be turned off or on. - Select (ID usage) on SYSTEM SETUP screen and press ‘SET’ on touch pad. - Preset: NO, FLASH MEMORY - ID USAGE: Choose ID USAGE on touch pad. Choose YES or NO on touch pad.
Page 38
<CHILD/ADULT/AUTO> It selects the print format of result sheet. Choose ‘ ’ and on the initial screen of ‘SYSTEM SETUP’ to enter the menu. - Pre-set: AUTO - Select a print format with the touch pad. - Press ‘SET’ button on touch pad to save it. - Return to SYSTEM SETUP screen by pressing ‘CLOSE’...
Page 39
Adjust the height meter and select the use of height meter. - Preset: 000.0cm, OFF - Adjustable range: ±99.9cm - Select ‘ ’ (HEIGHT METER) to enter menu screen. - Adjust the value by pressing ‘▼, ▲’ button on touch pad. - Press ‘YES’...
Once turning on the device, you can see the screen same as right picture. 1. ID search Press ‘ ’ button on the initial screen. Enter a 20-digit ID with alphabets and numbers mixed and press ‘ ’ button. You can see the results of the ID or print them.
1. Precaution for measurement The reliability of the results can be assessed by its accuracy. The "Accuracy" of the device is determined by comparing the actual body composition and the results from Body Composition Analyzer. The "Reproducibility" is determined when the device gives the identical results under the same conditions.
composition through continuous analysis and compare the results. Make sure that the body composition should are measured under the same physical and environmental conditions. If the condition before the measurement such as volume of a meal, meal time, and activities (exercise, sauna, drinking lots of beverage, urination, etc.) are kept same, the reproducibility of a device is obtained.
Page 43
When using a ankle electrode, be careful not to trip on the electrode before and Caution after a measurement. Use the ankle electrode after reading and understanding the instructions enough. Especially the elderly and the infirm have to be more careful of the safety while using the ankle electrode.
3) Measuring Posture - Step the scale in the bare feet. Stretch both arms and spread them 30° from the body. - Press start buttons with thumbs for 2 ~ 3 seconds to start the measurement. Once it starts, release the start button and hold the same posture until the measurement is over. - Do not speak or move the body until the measurement is completed.
Page 45
Note 1. If ID is already registered in previous time, input ID and press ‘ '. The data of Height, Gender and age saved in ID automatically appears on the display. The saved data can be changed. 2. When transmit the member information from software to the device, ID USAGES screen will appear.
Page 46
⑤ Measurement posture 2 The screen changes as shown in the picture. - Grip electrode handles correctly and press start buttons with thumbs at the same time. - Impedance measurement starts by pressing start buttons. - Do not move or speak during measurement. ⑥...
Page 47
⑧ Scanning QR code - Press the ‘QR code’ on the device screen to enlarge the icon and scan the ‘QR code’ with a mobile device to save the data in the server. After scanning the ‘QR code’, you can check the measurement data with your mobile device and manage it at will from the server in which it is saved.
An Ultrasonic Height Meter is an optional part. When height meter is connected to the device, it measures the user’s height in accurate way. [Measuring procedure] ① Connect the device to ultrasonic Height Meter. ② When stepping on the scale, the message “It stars a measurement.”...
The blood pressure monitor from SELVAS Healthcare, Inc. can be connected to the device as STORAGE OF DATA USING USB MEMORY an option. In this way, the blood pressure can be monitored together with weight control. It helps to manage the body fat while checking the blood pressure simultaneously. The measuring procedure is as follows.
1. Storage of data 1) On selecting FLASH MEMORY ① Insert USB memory stick into USB(A) jack placed on the back side of the device. ② The following message appears. ‘Do you want to write data to USB memory stick?’ on initial screen.
1. USB memory should be inserted only at the initial screen. Note 2. When there’s no data saved in FLASH MEMORY, the message “No saved data.” will appear. Please insert USB memory after measuring body composition. 3. When the saving format is changed from USB MEMORY to FLASH MEMORY, the data saved in USB MEMORY should be transferred to PC.
Page 52
1) Connect printer Beside the results displayed in LCD, more information can be printed out in the A4 result sheet. The printing procedure using A4 printer is as followings. ① Connect the device to A4 printer. ② Connect the device to a computer where basic management program is used 2) Result sheet There are two kinds of result sheet.
RESULT INTERPRETATION Here's the explanation and the criteria of the printed results. 1. Personal Data The subject's ID / name, date, height, weight, age and gender are indicated on the result sheet. 2. Company Logo The user can input LOGO such as name of hospital, sports center, or obesity clinic, telephone number, address, contact person, etc.
Page 54
*EAST ASIA thin normal overweight obese < 18.5 18.5 ~ ≤ 23 23 ~ ≤ 25 over 25 * EU and etc. thin normal overweight obese < 18.5 18.5 ~ ≤ 25 25 ~ ≤ 30 over 30 5. Abdominal Analysis Abdominal fatness is divided into subcutaneous type and visceral type.
Page 55
1) B.M.R. (Basal Metabolic Rate) B.M.R. refers to the calories required to maintain human body's basic function such as movement of heart, brain, neural transmission, regulating body temperature and so on. B.M.R. is in proportion to S.L.M. because body fat stores energy while muscle consumes energy. Therefore, even if the weight is same between persons, the person with more muscle has greater B.M.R.
Edema is the unbalanced state of intra and extra cellular water. Edema can be increased by salty STORAGE & MAINTENANCE food, malnutrition, postpartum, exercise, temporary fatigue etc. It is divided into 3 steps; Optimal, Borderline, Over. 13. Control guide Control guide shows goal to control weight, mass of body fat, and soft lean mass based on body composition analysis result.
Page 57
1) Pay attention to the allowable value to electric current. 2) Avoid direct sunlight, humidity, dust, thick oil and salty or extreme changes in temperature. 3) Do not install or store the device in a place where any chemicals or gas is stored. 4) Do not use the device in any unstable, vibrating, or impact-giving area.
ERROR & REPAIR 1. Kinds of Error & Repair Error Cause Repair • Clean the measuring parts (the electrodes, When the subject’s body impedance palms, and soles) and try again. Out of deviates from the limit • Measure again with correct posture. range of - Insufficient touch to electrodes •...
Page 59
When the subject’s height is deviated Can’t input • Input height correctly. If the subject’s height from the limit the height is out of range, height can't be entered. - Incorrect input of height • Measure the weight again. Don't move or speak during measurement.
2. Error & Repair Error Cause Repair • Measuring method. • Measure again in stable physique. Measuring is done under • If there is movement or speaking during unstable hydration state measurement, the weight and impedance are such just after not correct.
AFTER SERVICE 1. AFTER SERVICE If there is any problem with the unit, please follow the steps below; ※ Contact our company’s Overseas Service Department immediately. After gathering the model name, Serial Number, date of purchase and description of the problem, contact our company with information shown below.
SPECIFICATION Model ACCUNIQ BC360 Measuring method Tetra-polar electrode method using 8 touch electrodes. Frequency Range 5, 50, 250 kHz Measuring site Whole body and Segmental measurement (arms, legs, and trunk) [Result for Body Composition Analysis] Main items Body Composition Analysis (Weight, LBM, Body fat, SLM, Protein,...
Page 63
Storage ambient Ambient temperature range -25 to +70 °C Relative humidity range lower than 93 % RH ※ For purpose of improvement, specifications and design are subject to change without notice.
WARRANTY Warranty Name of product Body Composition Analyzer Name of model ACCUNIQ BC360 Serial number Period of warranty Within 1 year from the date of purchase Date of purchase Customer Add. Name Tel. Dealer (market) Add. Name Tel. Note - When you receive this warranty, make sure that the name of the dealer and the month, day and year of purchase are all completed.
INSTRUCTIONS FOR ASSEMBLY 1. How to install a device To ensure the operator's security, please work in team of minimum two people during installation, packing and transport. (1) Components 4mm 6angles wrench Body cover Main unit M6 bolt Adapter and Power cable (2) Unpacking ①...
Page 66
③ After opening the Carton Box, fold the box cover outwardly not give contact to the air pack for protecting products. Take out the protection air pack and check its components inside. Air pack (3) Installation ① More than two workers hold the device, and lift it up. Take the device out of the Carton Box. ②...
Page 67
③ While one person is holding the column, remove the plastic package from the Body and scale. ④ While the one person is holding the column, another inserts two M6 bolts into each side of column and fixes them using 4mm 6angles T-wrench.
Page 68
(4) Assembling the body cover ① Push the body cover in the arrow direction shown in the picture below and adhere to the scales packing. Tight contact Body cover 완전 밀착 체중계 패킹...
Page 69
(5) Adjust the level Connect the power Check the level of the device. If it is not at level, adjust the level using the four wheels. After adjusting the level, connect the provided adapter and power cable and turn on the device. Power connection...
2. Assembling a height meter (option) Carefully read below and start to assemble the components for a correct installation (1) Components for installing a height meter 6angles 1 pc of M4 flat 2 pcs of M6 4 pcs of M4 wrench bolt headed bolt wrench...
Page 71
(3) Installing the height meter ① Pay attention during the installation and follow the instruction below carefully. Lay the device aside as shown in the picture. Put a prop or books to support the column so that LCD would not touch the ground. Place the handle electrodes at a safe spot.
Page 72
③ Fix the bottom plate of the height meter to the bottom plate of the scale. Make sure that 6 holes are matched. Put M4 wrench bolts and M6 wrench bolts to the appropriate holes and fasten them tightly. (Use 3mm wrench tool for M4 wrench bolts. / Use 5mm wrench tool for M6 wrench bolts.) ④...
Page 73
⑤ After the bottom plate of the height meter is installed, stand the device on the flat surface. Please do the operation following the instruction carefully. Remove the prop, paper or vinyl on the floor. ⑥ Take the height meter body out of the box and unwrap the body. Push up the head of the height meter to the (A) arrow direction and push it to the (B) arrow direction.
Page 74
⑦ Lift up the fixing lever to the arrow direction as shown in the picture. ⑧ Slightly press the rubber pad located at the inner body cover to make the height meter body put into easily. Put the height meter body in the body cover. (*Note: RS-232C connector at the bottom of the height meter body should be placed at the connector socket.) Rubber pad RS-232C...
Page 75
⑩ Lift up the fixing lever located at located at the middle of the height meter body to the arrow. Lift up the inner column to the end and pull down the fixing lever to the arrow and fix it. Also move the fixing rack to the spot where the fixing lever is matched.
Page 76
⑪ Connect a RS-232C cable to the “HEIGHT” port on the back side of the device. Connect it to the adapter and turn on the power.
3. Assembling a Bluetooth (option) Connect the provided Bluetooth to the BLUETOOTH port on the back side of the device. Users can check and manage the result data on the exclusive mobile device app via Bluetooth connection. ① Components for Bluetooth Bracket Bluetooth Union of bracket...
Page 78
③ Connect the antenna to the Bluetooth. Connect the main body connecting cable to the reverse side of the antenna and fix the cable by screwing the bolts in with a (-) driver. ④ Connect the unconnected side of the cable to ‘ EXTERNAL PORT’...
Page 79
⑤ Fix the Bluetooth to the back side of the main body with the provided bracket using a (+) driver. The installation is completed by turning on the device. Joint of bracket...
4. Assembling an ankle electrode (option) When installing, packing and transporting, please work in terms of minimally 2 people to ensure safe operation. (1) Components for installing an ankle electrode M4 bolt M12 bolt 10mm 6angles wrench Flat Washer Flat Washer Ankle electrode Top cover...
Page 81
② Detach the top cover from the scale by using a (-) driver. ③ Check the RS-232C port of the weight scale and ankle electrode. Ankle electrode RS-232C port ④ Connect the RS-232C port of the ankle electrode to the weight scale as shown in the picture. Ankle electrode RS-232C port...
Page 82
⑤ Grip the ankle electrode with one hand and fix it on the scale firmly by using M12 bolt-10mm 6 angle wrench and M4 bolt-3mm 6 angle wrench. M12 bolt M4 bolt ⑥ After it, try shaking the ankle electrode to check if the fixation is good or not. (X) Bad (O) Good...
Page 83
⑦ Remove the protective vinyl and double-faced sticker inside of the top cover. ⑧ Attached the top cover on the ankle electrode to the arrow direction in the picture.
Page 84
⑨ Power on After finishing the installation, connect the adapter and power cable and turn on the device. Adapter connecting Socket...
Page 85
Pass/Fail 4 Measurement Proper measurement Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BC360 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
Page 86
Pass/Fail Other 1 Clock Present date/time Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BC360 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
Page 87
EUROPEAN REPRESENTATIVE VITAKO Sp. z o.o. ul. Stanisława Żaryna 7c 02-593 Warszawa, POLAND TEL: +48 22 400 8000 BC360E-20161124 Rev1.1...