EMU Modem User Manual
Revision: V.06
Emu Modem
User Manual
Rev: V0.6
t h
7
June 2016
Connect edI O Cont act :
TBD
ConnectedIO CONFIDENTIAL

Advertisement

Table of Contents
loading

Summary of Contents for ConnectedIO Emu EM1000T-NA

  • Page 1 EMU Modem User Manual Revision: V.06 Emu Modem User Manual Rev: V0.6 June 2016 Connect edI O Cont act : ConnectedIO CONFIDENTIAL...
  • Page 2 Revision History: Date Rev No. Description 7-6-2016 V0.1 Initial draft ConnectedIO 7/20/2016 V0.2 Draft update ConnectedIO 7/26/2016 V0.3 Draft update ConnectedIO 7/27/2116 V0.4 SIM Size update ConnectedIO 8/16/2016 V0.5 Temperature Range ConnectedIO 3/21/2017 V0.6 Antenna and Certification updates ConnectedIO ConnectedIO CONFIDENTIAL...
  • Page 3: Table Of Contents

    Set-up 6.2. AT Command 6.3. APN Change Antenna 7.1. Antenna – Installation Guidelines 7.2. Maximum Antenna Gain 7.3. Recommended Antennas Environmental 8.1. Operating Environment 8.2. Physical Parameters Approvals and Certifications 9.1. Manufacturing 9.2. North American Certifications 9.2.1 EM1000T-NA ConnectedIO CONFIDENTIAL...
  • Page 4 EMU Router User Manual 9.3. European Certifications 9.3.1 EM1000T-EU ConnectedIO CONFIDENTIAL...
  • Page 5: Introduction

    EMU Router User Manual 1. Introduction The ConnectedIO Emu Modem is designed and developed for applications requiring high throughput, devices requiring worldwide coverage, and for applications primarily in the areas of telematics for M2M applications. The Emu Modem is a compact module offering full LTE connectivity with 3G fallback across numerous carrier independent networks depending on the end customers’...
  • Page 6: Activation

    The connection manager installer will create an icon on the desktop. If not, type “TCM” in your Windows search field. Everything should be auto configured and the only action required is to click the “Play” button located in the TCM as shown in the picture below. 5. System Configuration – Windows- ConnectedIO CONFIDENTIAL...
  • Page 7: At Command

    Verify which serial port the device should be communicating on in the Windows Device Manager. Click on the “Play” button it will connect the Telit AT Controller to the serial port so communication can be established with the modem. ConnectedIO CONFIDENTIAL...
  • Page 8 EMU Router User Manual Click on “AT terminal” button. The previous step will open AT terminal as shown below: ConnectedIO CONFIDENTIAL...
  • Page 9 The AT command format is “AT+ Command” for example: AT+CSQ. Enter the AT command and click “Execute”. Figure 1 AT command responses will be displayed in the terminal window on the right side of the Telit AT Controller software. Figure ConnectedIO CONFIDENTIAL...
  • Page 10 EMU Router User Manual Figure 1: AT Command Example ConnectedIO CONFIDENTIAL...
  • Page 11: Apn Change

    Typically, your APN is auto-configured or auto-detected. The APN Change command allows you to change the local telecommunication company. Enter AT command for changing APN in AT terminal as follows: AT+CGDCONT=1,”IPV4V6”,”<your APN name>” and click the “Execute” button Figure Figure 2: APN Change ConnectedIO CONFIDENTIAL...
  • Page 12 EMU Router User Manual To verify the APN setting update was successful, enter AT command “AT+CGDCONT?” See Figure Figure 3: Check APN Function ConnectedIO CONFIDENTIAL...
  • Page 13: Mode Setting

    In Auto mode the system will automatically coordinate between the different modes based on network availability for the particular carrier. Start Telit Connection Manager and click on the “Settings” button. Then click on the “Network settings” button. You’ll find “Wireless Data Service Selection” as a drop down list. ConnectedIO CONFIDENTIAL...
  • Page 14: System Configuration - Linux

    However, if the APN does not auto-configure, please refer to section 6.3 From a root shell type: ifconfig wwan0 up qmicli -d /dev/cdc-wdm0 --wds-start-network= --client-no-release-cid dhclient wwan0 Verify that if the network interface has a valid IP address: • ConnectedIO CONFIDENTIAL...
  • Page 15: At Command

    EIRP limitations. Typical antenna Gain in most M2M applications should not exceed 2dBi. At least 20cm of separation distance between the antennas, the collocated router transmitters, and • the human body must be maintained at all times. ConnectedIO CONFIDENTIAL...
  • Page 16: Maximum Antenna Gain

    700-960/1575-2700MHz Dipole, 1-4dBi Gain with SMA Articulating Plug 8. Environmental 8.1. Operating Environment Operating Temperature: -30°C to +85°C • Storage Temperature: -30°C to +85°C • 8.2. Physical Parameters Size: 84mm x 77mm x 17.8 • Weight: 60gr. • 9. Approvals and Certifications 9.1. Manufacturing ConnectedIO CONFIDENTIAL...
  • Page 17: North American Certifications

    EMC (R&TTE art. 3.1b): EN 301 893 V1.7.1 (2012-06) § EN 301 489-1 V1.9.2 (2011-09) § § EN 301 489-24 V1.5.1 (2010-10) EN 55032:2012 + AC:2013, Class A § § EN 61000-3-2:2014 § EN 61000-3-3:2013 § EN 55024:2010 ConnectedIO CONFIDENTIAL...
  • Page 18 This device has been tested and conforms to the Australian Communications and Media Authority’s (ACMA) regulatory arrangements for EMC and therefore as attained the RCM mark. Compliance with this directive implies conformity to the following: AS/CA S042.1:2015 AS/CA S042.4:2015 ConnectedIO CONFIDENTIAL...