LOCATION AND CONNECTION OF THE QUANTUM PUMP

The connection point for the Quantum pump may
vary depending on the system to be cleaned, and the
availability of suitable connection points.
However the optimum location is via the central
heating circulation pump, using either the special
hoses supplied to connect across the pump unions,
or using the optional CP2 adaptor connected to the
pump body. (see page F.2)
Issue: Mar 2008
Section B – Using the Quantum for Power Flushing
Generally the unit should be located in a room with a
suitable drain point, and near to a convenient mains
water supply, such as a bathroom or kitchen. The
cold water supply for a washing machine or dish-
washing machine is a convenient source when a
mixer tap makes connection of a hose difficult.
The normal precautions during work on any heating
system should be taken, and it is prudent to place
the pump on a waterproof groundsheet or drip tray.