Air Quality Engineering MistBuster 500 Installation And Operation Manual

Air Quality Engineering MistBuster 500 Installation And Operation Manual

Machine mountable mist & smoke collector
Hide thumbs Also See for MistBuster 500:

Advertisement

S U P P L Y I N G
C L E A N
A I R
T O
I N D U S T R Y
MistBuster 500
®
Installation and Operation Manual
Protected by U.S. Patent Number 6,428,611
Machine Mountable Mist & Smoke Collector
7140 Northland Drive North, Brooklyn Park, MN 55428-1520 USA
FAX: (763) 531-9900 EMAIL: info@air-quality-eng.com WEB SITE: www.air-quality-eng.com
TOLL FREE: 1-800-328-0787
Air Quality Engineering Inc., has a policy of continuing product improvement and reserves the right to make changes
in design and specification without notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MistBuster 500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Air Quality Engineering MistBuster 500

  • Page 1 7140 Northland Drive North, Brooklyn Park, MN 55428-1520 USA FAX: (763) 531-9900 EMAIL: info@air-quality-eng.com WEB SITE: www.air-quality-eng.com TOLL FREE: 1-800-328-0787 Air Quality Engineering Inc., has a policy of continuing product improvement and reserves the right to make changes in design and specification without notice.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE SPECIFICATIONS INSTALLATION Direct Mount Ducted Installations Installing Plenum Machine Mount Stand Ceiling Mount Pedestal Stand Drain Installation Electrical START UP ROUTINE MAINTENANCE HEPA FILTER OPTION INSTALLATION TROUBLESHOOTING PARTS LIST WARRANTY...
  • Page 3: Specifications

    SPECIFICATIONS - IMPORTANT - THE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES. THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPECIFICATIONS EXACTLY. ALSO, THIS PRODUCT IS TESTED AND CALIBRATED UNDER CLOSELY CONTROLLED CONDITIONS AND SOME MINOR DIFFERENCES IN PERFORMANCE CAN BE EXPECTED IF THOSE CONDITIONS ARE CHANGED.
  • Page 4: Installation

    INSTALLATION INSPECTION The MistBuster Model 500 can be mounted direct- The MistBuster air cleaner should be checked for ly to the enclosure on a machine tool. The col- any shipping damage that may have occurred dur- lected mist droplets simply drain back into the ma- ing shipping.
  • Page 5: Ducted Installations

    ners. Carefully position the MistBuster over 6. Replace the mesh impingers and the electron- the opening and bolt the unit in place. ic cell. Please make sure the arrows on the cell and filters are pointing up. 5. The MistBuster comes complete with a 10’[3.05m] power cord.
  • Page 6: Ceiling Mount

    1. Remove the six 1/4” bolts on the back of the 3. Use a crane or fork truck to lift the assembled MistBuster and install the two L-brackets. MistBuster onto the machine tool. CAUTION: Make sure the MistBuster is secured to the 2.
  • Page 7: Pedestal Stand

    Buster and lift the unit up to the pedestal stand. Align the MistBuster and insert and tighten the 1/4-20 bolts with lock washers to secure the MistBuster to the pedestal stand. Install the plenum per the instructions in the Installing the Plenum section. 5.
  • Page 8: Electrical

    Mcode Speed Controller Option The MistBuster 500 can be ordered with the Cord Connected Mcode speed control shipped separately. In addi- The MistBuster is equipped with a 10’[3.05m]...
  • Page 9 2. Apply silicone glue to the top of the module around the outside of the bolt pattern Assembling the Two Units Together 1. Set the MistBuster 500 on top of the DPM module making sure the 7/8”[22mm] diameter holes line up between MistBuster and DPM module.
  • Page 10 FIGURE 15 – SCHEMATIC FOR DOUBLE PASS MODULE...
  • Page 11: Start Up

    Total Oil Cleaner The mist impingers and electronic cell will need to Air Quality Engineering, Inc. offers Total Oil be cleaned periodically. The exact maintenance Cleaner. This detergent was specifically designed interval is determined by each specific application.
  • Page 12: Hepa Filter Option Installation

    HEPA FILTER OPTION NOTICE Handle the HEPA filter carefully to avoid damage to the filter media. The HEPA filter weighs 25 lbs.[55kg] clean and adds an additional 12”[305mm] to the height of the MB. 1. Install the two anchor brackets to the center of both sides of the MistBuster cabinet by remov- ing the two bolts/washers (on each side of the MistBuster).
  • Page 13: Parts List

    PARTS LIST DESCRIPTION 120 VAC 208-240 VAC Aluminum Mesh Impingers, 2”[51mm] think 2 req. 41205 41205 ESP Cell 07192 07192 Aluminum Mesh Impingers, 1”[25mm] think 1 req. 41050 41050 Speed Controller 10251 10253 Indicator Light 10097 10097 Motor / Impeller 07184 07185 Capacitor...
  • Page 15: Warranty

    CERTIFICATE OF WARRANTY THREE-YEAR LIMITED WARRANTY Air Quality Engineering, Inc. (AQE), warrants to the original purchaser, subject to the conditions below, that if the “Product” covered by this warranty should fail to perform by reason of improper workmanship or material, AQE will during the period of three (3) years from the date of original purchase either (i) replace the product or (ii) provide all necessary parts to repair the product without charge.