Summary of Contents for Air Quality Engineering MistBuster 500
Page 1
7140 Northland Drive North, Brooklyn Park, MN 55428-1520 USA FAX: (763) 531-9900 EMAIL: info@air-quality-eng.com WEB SITE: www.air-quality-eng.com TOLL FREE: 1-800-328-0787 Air Quality Engineering Inc., has a policy of continuing product improvement and reserves the right to make changes in design and specification without notice.
TABLE OF CONTENTS PAGE SPECIFICATIONS INSTALLATION Direct Mount Ducted Installations Installing Plenum Machine Mount Stand Ceiling Mount Pedestal Stand Drain Installation Electrical START UP ROUTINE MAINTENANCE HEPA FILTER OPTION INSTALLATION TROUBLESHOOTING PARTS LIST WARRANTY...
SPECIFICATIONS - IMPORTANT - THE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES. THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPECIFICATIONS EXACTLY. ALSO, THIS PRODUCT IS TESTED AND CALIBRATED UNDER CLOSELY CONTROLLED CONDITIONS AND SOME MINOR DIFFERENCES IN PERFORMANCE CAN BE EXPECTED IF THOSE CONDITIONS ARE CHANGED.
INSTALLATION INSPECTION The MistBuster Model 500 can be mounted direct- The MistBuster air cleaner should be checked for ly to the enclosure on a machine tool. The col- any shipping damage that may have occurred dur- lected mist droplets simply drain back into the ma- ing shipping.
ners. Carefully position the MistBuster over 6. Replace the mesh impingers and the electron- the opening and bolt the unit in place. ic cell. Please make sure the arrows on the cell and filters are pointing up. 5. The MistBuster comes complete with a 10’[3.05m] power cord.
1. Remove the six 1/4” bolts on the back of the 3. Use a crane or fork truck to lift the assembled MistBuster and install the two L-brackets. MistBuster onto the machine tool. CAUTION: Make sure the MistBuster is secured to the 2.
Buster and lift the unit up to the pedestal stand. Align the MistBuster and insert and tighten the 1/4-20 bolts with lock washers to secure the MistBuster to the pedestal stand. Install the plenum per the instructions in the Installing the Plenum section. 5.
Mcode Speed Controller Option The MistBuster 500 can be ordered with the Cord Connected Mcode speed control shipped separately. In addi- The MistBuster is equipped with a 10’[3.05m]...
Page 9
2. Apply silicone glue to the top of the module around the outside of the bolt pattern Assembling the Two Units Together 1. Set the MistBuster 500 on top of the DPM module making sure the 7/8”[22mm] diameter holes line up between MistBuster and DPM module.
Page 10
FIGURE 15 – SCHEMATIC FOR DOUBLE PASS MODULE...
Total Oil Cleaner The mist impingers and electronic cell will need to Air Quality Engineering, Inc. offers Total Oil be cleaned periodically. The exact maintenance Cleaner. This detergent was specifically designed interval is determined by each specific application.
HEPA FILTER OPTION NOTICE Handle the HEPA filter carefully to avoid damage to the filter media. The HEPA filter weighs 25 lbs.[55kg] clean and adds an additional 12”[305mm] to the height of the MB. 1. Install the two anchor brackets to the center of both sides of the MistBuster cabinet by remov- ing the two bolts/washers (on each side of the MistBuster).
CERTIFICATE OF WARRANTY THREE-YEAR LIMITED WARRANTY Air Quality Engineering, Inc. (AQE), warrants to the original purchaser, subject to the conditions below, that if the “Product” covered by this warranty should fail to perform by reason of improper workmanship or material, AQE will during the period of three (3) years from the date of original purchase either (i) replace the product or (ii) provide all necessary parts to repair the product without charge.