Power factor controller

Advertisement

Quick Links

GUIDA RAPIDA REGOLATORE R5 / QUICK SETUP POWER FACTOR CONTROLLER (PFC) R5
Principali caratteristiche / General description:
-
Controllore automatico del fattore di potenza a 5 gradini per reti monofase e trifase con e senza neutro / 5-step power factor automatic controller for single-
phase and three-phase networks with or without neutral connection.
-
Display con icone retroilluminate a LED rossi di chiara leggibilità anche da distanza, 5 tasti di navigazione per funzioni ed impostazioni / Display with backlit
icons with red LEDs, 5 navigation keys for functions and settings.
-
Opzioni di connettività Radio 868MHz, NFC e RS485 / 868MHz Radio, NFC and RS485 connectivity options.
-
Misure di tensione con precisione 0,2%±0,5 digit / Voltage measurement accuracy: 0.2%±0.5 digit.
-
Misure di corrente con precisione 1%±0,5 digit / Current measurement accuracy: 1%±0.5 digit.
Allarmi completamente definibili dall'utente e associabili alle uscite a relè / Alarms can be completely defined by the user and associated to relay outputs.
-
Avvertenze/Warnings:
Leggere attentamente la seguente guida prima dell'utilizzo del regolatore
Lo scopo di questa guida è quello di offrire il modo più rapido per installare ed iniziare a
utilizzare i modelli della gamma di regolatori R5 presenti nel manuale completo disponibile
al link:
https://www.ducatienergia.com/product.php?lang=it&id=8&cat=13&product=89
L'installazione e il cablaggio del dispositivo devono essere effettuati da personale
qualificato.
Un interruttore automatico o un sezionatore deve essere incorporato nell'impianto elettrico,
posizionato adeguatamente nelle strette vicinanze del regolatore ed essere facilmente
raggiungibile da parte dell'operatore. Deve essere marchiato come il dispositivo di
sezionamento dell'apparecchio: IEC/EN 61010-1 § 6.11.2
Pericolo di elettrocuzione ustione e arco elettrico. Dotarsi di un equipaggiamento di
protezione personale adatto a rispettare le attuali norme per la sicurezza elettrica.
Prima di procedere ai collegamenti verificare il sezionamento dell'alimentazione elettrica
con un dispositivo di rilevamento tensione che deve essere posto nelle vicinanze del
regolatore o comunque essere facilmente raggiungibile dall'operatore.
Se necessario pulire lo strumento utilizzare solo un panno umido.
La versione aggiornata di questo manuale e il manuale operativo completo sono consultabili
online al link:
https://www.ducatienergia.com/product.php?lang=it&id=8&cat=13&product=89
Il fabbricante, Ducati energia S.p.A., dichiara che i Regolatori R8 sono conformi alla
direttiva 2014/53/UE.
Il testo completo della dichiarazione di conformità UE è disponibile al seguente indirizzo
internet:
https://www.ducatienergia.com/product.php?lang=it&id=8&cat=13&product=89
364490257_GUIDA_RAPIDA_R5_V0L.PDF
Non smaltire l'apparecchio come rifiuto urbano misto
Do not dispose of the device as mixed municipal waste
Carefully read this guide before using the Power Factor Controller.
The purpose of this guide is to provide the quickest way to install and start using the
models of the range of R5 Power Factor Controllers listed in the complete manual
available on line at the link:
https://www.ducatienergia.com/product.php?lang=en&id=8&cat=13&product=89
The device must be installed and wired by qualified personnel.
A circuit breaker must be included in the electrical installation and must be installed
close to the equipment and within easy reach of the operator. It must be marked as the
disconnecting device of the equipment: IEC/EN 61010-1 § 6.11.2
Risk of electrocution, burns and electric arc. Obtain the personal protective equipment
appropriate to fulfil the current electrical safety standards.
Before making the connections, check the power supply disconnection with a voltage
detection device that must be placed close to the Power Factor Controller or, however,
be easily accessed by the operator.
If necessary, clean the instrument using only a damp cloth.
The updated version of this manual and the complete operating manual are available
on line at the link
https://www.ducatienergia.com/product.php?lang=en&id=8&cat=13&product=89
The manufacturer, Ducati energia S.p.A. declares that R5 Controllers comply with the
2014/53/EU directive.
The complete text of the EU declaration of conformity is available at the following
internet address:
https://www.ducatienergia.com/product.php?lang=en&id=8&cat=13&product=89
Pag.1 di 10
Rev. 0L
02/2018

Advertisement

loading
Need help?

Need help?

Do you have a question about the R5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ducati Energia R5

  • Page 1 Lo scopo di questa guida è quello di offrire il modo più rapido per installare ed iniziare a models of the range of R5 Power Factor Controllers listed in the complete manual utilizzare i modelli della gamma di regolatori R5 presenti nel manuale completo disponibile...
  • Page 2: Installazione / Installation

    364490257_GUIDA_RAPIDA_R5_V0L.PDF Rev. 0L 02/2018 Installazione / Installation Dimensioni / Dimensions 92,0mm +0,8mm -0mm Dimensioni / Dimensions 92,0mm +0,8mm -0mm Pag.2 di 10...
  • Page 3 364490257_GUIDA_RAPIDA_R5_V0L.PDF Rev. 0L 02/2018 Collegamento / Electrical Connection La presente figura illustra il collegamento in modalità FF1. Lo strumento ammette altre configurazioni di collegamento alla rete. This figure shows the connection in FF1 mode.The device allows other network connection configurations. www.ducatienergia.com Per i modelli con RS485 collegare B e T per attivare la resistenza di terminazione interna.
  • Page 4 Secondario del TA (figg. 1a, 1b, 2a e 2b) e della tensione nominale dei condensatori (fig. 3a e 3b) At first turn-on of the system, the PFC R5 performs an automatic insertion of capacitor banks to check the connections and the amount of batteries power.
  • Page 5 364490257_GUIDA_RAPIDA_R5_V0L.PDF Rev. 0L 02/2018 Procedura di avvio Regolatore / PFC R5 Startup procedure Passa alla schermata del parametro precedente / Annulla la modifica in corso Screen of the previous parameter / Cancel current change Modifica del valore di primario (Pri) o secondario (SEC) del TA o della...
  • Page 6 Rev. 0L 02/2018 Procedura di avvio Regolatore / PFC R5 Startup procedure Dopo l’impostazione dei valori di Primario e Secondario del TA e della tensione nominale dei condensatori, il regolatore controllerà i collegamenti di tensione/corrente inserendo ciclicamente le batterie di condensatori; sono previsti da un minimo di 2 cicli ad un massimo di 5 cicli di inserimento al termine dei quali il regolatore auto-imposterà...
  • Page 7 Rev. 0L 02/2018 Procedura di avvio Regolatore / PFC R5 Startup procedure Dopo il controllo del collegamento se la potenza di almeno una delle batterie di condensatori era già stata pre-impostata (ad es. durante un precollaudo in fabbrica) prima del controllo automatico dei collegamenti, il regolatore terminerà...
  • Page 8: Caratteristiche Tecniche

    364490257_GUIDA_RAPIDA_R5_V0L.PDF Rev. 0L 02/2018 Caratteristiche tecniche  Alimentazione:  Condizioni ambientali di funzionamento: o Temperatura di impiego: da -20 a +70°C o Tensione nominale: 400 o 230 VAC; o Temperatura di stoccaggio: -30-+80 °C o Limiti di funzionamento: 380÷415 VAC ±10% oppure o Categoria di sovratensione: ||| 220÷240 VAC ±10%;...
  • Page 9 364490257_GUIDA_RAPIDA_R5_V0L.PDF Rev. 0L 02/2018 Technical features  Power supply:  Environment conditions: o Operating temperature: -20 to +70 °C o nominal voltage: 400V~ o 230V~ o Storage temperature: -30 to +80 °C o operating limits: 380÷415 VAC ±10% or 220÷240 VAC o Overvoltage category: ||| ±10%;...
  • Page 10 Reset commands. (1) The default values of the parameters of the regulators installed on DUCATI energia PFC panel are shown in the leaflet inside the panel (2) The “Msg.” column indicates the message displayed alternately with the parameter value. Rif.