Series DA/DS-7000 Bourdon Tube Pressure Switches
are SPDT snap-action switches that combine extremely
high sensitivity and repeatability with easily adjustable set
and reset points through non-interactive external adjust-
ments. These switches have visible calibrated dials for set
points and on-off indicators to indicate switch actuation.
DA models are equipped with two external adjustments.
One sets the high pressure operating point; the other sets
the reset point. Deadband or the difference between set
and reset points is adjustable over the full scale. DS mod-
els have a fixed deadband.
NOTE: The DS7300 has no status indicator.

INSTALLATION

The switch may be mounted in any position. Select a loca-
tion recommended by equipment manufacturer. Where
excessive vibration occurs, mount the switch remotely,
using an appropriate remote connection and mounting
bracket. See accessories, below.

ACCESSORIES

Mounting
Bracket
Siphon
Series DA/DS-7000 Bourdon Tube Pressure Switches
Specifications - Installation and Operating Instructions
Remote
Connection
Pigtail
Contact: Northeast Controls Incorporated
P.O. Box 275 - Upper Saddle River, New Jersey 07458
Tel: 201-327-7660 | Fax: 201-327-3242 | sales@nciweb.net
www.nciweb.net/dwyer
2-1/4
[57.15]
6-1/64
[152.8]
DIA.
MERCOID
CONTROL
1/4 N.P.T.

PHYSICAL DATA

Pressure Range: Models range from 0 to 30" Hg (0 to
762.5 mm/Hg) Vac. to 800 to 8000 psig (55.16 to 551.6
bar).
Maximum Temperature: 180°F (82°C). For higher tem-
perature media applications, a remote connection or siphon
(pigtail) should be used.
Pressure Connections:
Ranges 500 to 5000 psig and 800 to 8000 psig.
Housing: Pressed steel with transparent cover.
Wiring Connections: Three-screw type.
Wetted Parts: Same as Bourdon tube material (brass,
403SS or 316SS) on all ranges except 23K, 24K, and 9K,
which have carbon steel bottom connections.
Weight: 4 lb/1.8 kg (standard); 6 lb/2.7 kg (weatherproof);
8 lb/3.6 kg (explosion-proof)
Max. Pressure: Max. adjustment of operating range.
CAUTIONS:
Control movement must not be oiled. Do not overload.
Note electrical rating on name plate and be sure that total
current passing through the switch is within specified rat-
ing.
When testing a boiler or system, never exceed maximum
pressure rating on control or it may be seriously damaged.
Remove control if higher pressures are required.
Do not fail to use a siphon on steam where range is 35 lbs
(2413 mbar) or more.
Bulletin IN-523
1-5/8
[41.28]
1/2 [12.7]
CONDUIT HOLE
ADJUSTMENT SCREWS
7/8 [22.23]
5/8 [15.88]
" NPT standard;
" NPT on
1
/
1
/
4
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-7000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercoid DS-7000 Series

  • Page 1 Series DA/DS-7000 Bourdon Tube Pressure Switches Specifications - Installation and Operating Instructions 2-1/4 [57.15] 6-1/64 [152.8] DIA. 1-5/8 [41.28] MERCOID CONTROL 1/2 [12.7] CONDUIT HOLE ADJUSTMENT SCREWS 1/4 N.P.T. 7/8 [22.23] 5/8 [15.88] PHYSICAL DATA Series DA/DS-7000 Bourdon Tube Pressure Switches are SPDT snap-action switches that combine extremely Pressure Range: Models range from 0 to 30”...
  • Page 2 Bulletin IN-523 Page 2 GENERAL PURPOSE CONTROLS, TYPES DA, DL, DR, DS WEATHER-RESISTANT (RAINTIGHT) Mount control in any position. Do not twist the case when NEMA 2, 3, TYPES N3DAW, N3DRW, N3DSW installing. Use a wrench on the square part of the control These switches are supplied with flanged case, bottom con- nection, for surface mounting.
  • Page 3 Bulletin IN-523 Page 3 ADJUSTMENTS: HOW TO SET OPERATING POINT SINGLE ADJUSTMENT TYPES—FULLY AUTOMATIC: Double Adjustment Types - Fully Automatic: Models prefixed DS, DSH, DSW, N3DSW are equipped with With double-adjustment switches (prefixed DA, DAH or a single adjustment. Differential is fixed (not adjustable). The DAW), adjust the upper pointer “U”...
  • Page 4 Bulletin IN-523 Page 4 TYPE DA TYPE DS Double Adjustment Single Adjustment RANGES: Minimum Differential Fixed Differential SPDT SPDT SPDT (2) SPDT Adjustable DS-7331-153 DA-7031-153 DS-7231-153 DS-7231-804 Range Bourdon Tube Operating Range DAW-7033-153 DSW-7333-153 DSW-7233-153 DSW-7233-804 Number Material (PSIG) DAH-7031-153 DSH-7331-153 DSH-7231-153 DSH-7231-804...

This manual is also suitable for:

Da-7000 series

Table of Contents