Advertisement

2D Scanner Setting Manual
Catalog .................................................................................................................... 1
I、Default Setting .................................................................................................... 5
1. Set Custom Defaults .................................................................................... 5
2. Recall default ............................................................................................... 5
II、Interface setting ................................................................................................. 5
1. introduce ...................................................................................................... 5
2. USB interface setting ................................................................................... 5
3. RS232 Baud rate ......................................................................................... 8
III、Keyboard setting............................................................................................. 12
1. Keyboard language setting ........................................................................ 12
2. Keyboard combination configuration.......................................................... 17
3. Character Shift ........................................................................................... 19
2D Scanner Setting Manual
EC323

Catalog

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EC323 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gems EC323

  • Page 1: Table Of Contents

    2D Scanner Setting Manual EC323 2D Scanner Setting Manual Catalog Catalog ........................1 I、Default Setting ....................5 1. Set Custom Defaults ..................5 2. Recall default ....................5 II、Interface setting ....................5 1. introduce ...................... 5 2. USB interface setting ................... 5 3.
  • Page 2 2D Scanner Setting Manual IV、input/output configuration ................20 1. Power Up Beeper..................20 2. Power On BELCharacter ................20 3. Trigger Click ....................20 4. Good read ....................22 5. LED ......................24 6. Power Save mode..................24 7. Read delay ....................26 8.
  • Page 3 2D Scanner Setting Manual 3. Suffix setting ....................37 4. Intercharacter and Intermessage Delays ........... 39 VI、Symbologies Configuration ................40 1. All Symbologies..................40 2. Codabar ..................... 40 3. Code39 ...................... 42 4. Interleaved 2 of 5 ..................45 7. Straight 2 of 5 Industrial ................50 8.
  • Page 4 2D Scanner Setting Manual 20. GS1 DataBar Omnidirectional..............76 21. GS1 DataBar Limited ................76 22. GS1 DataBar Expanded ................77 23. PDF417 ....................78 24. MicroPDF417 ................... 79 25. GS1 Composite Codes ................80 26. TCIF Linked Code 39 (TLC39) ..............82 27.
  • Page 5: I、Default Setting

    2D Scanner Setting Manual I、Default Setting 1. Set Custom Defaults Set Custom Defaults 2. Recall default Recall Defualt Remark : USB inteface as default setting II、Interface setting 1. introduce The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal.
  • Page 6 2D Scanner Setting Manual following steps: (1)USB PC Connecting the WINDOWS PC and Scan the “USB PC Keyboard” setting code, the scanner could be setting as the USB keyboard mode. This setting will add return and line break after the scanned information, if you don’t want the suffix, please refer to the suffix setting chapter.
  • Page 7 2D Scanner Setting Manual (4)USB IBM USB IBM (5)USB HID POS If the scanner need to be recognized as HID POS device, please scan the “USB HID POS” barcode. USB HID POS (6)USB COM When the application software requires the serial environment, the USB device could be recognized as USB COM device,and it needs to install the USB COM driver.
  • Page 8: Rs232 Baud Rate

    2D Scanner Setting Manual 3. RS232 Baud rate When the engine connect the terminal through TTL/RS232, should setting the same baud rate in engine and terminal, including the transmission speed, check bit and control flow, etc. The transmission speed is the baud rate, the default value is 115200.
  • Page 9 2D Scanner Setting Manual 19200bps 38400bps 57600bps *115200bps...
  • Page 10 2D Scanner Setting Manual 4. RS232 data length RS232 data length including the data bit, stop bit, check bit. The default is 8 data bit, 1 stop bit and no check bit. 7 data bit, 1 stop bit, no check bit 7 data bit, 2 stop bit, no check bit *8 data bit, 1 stop bit, no check bit 7 data bit, 1 stop bit, even check bit...
  • Page 11 2D Scanner Setting Manual 8 data bit, 1 stop bit, odd check bit...
  • Page 12: Keyboard Setting

    2D Scanner Setting Manual III、Keyboard setting 1. Keyboard language setting When the engine be recognized as a keyboard input device, you need to set the different language in different country. The default language is US English. Keyboard Defualt *English (US) Belgium Finland France...
  • Page 13 2D Scanner Setting Manual Italy Switzerland - German England Danmark Norway Spain Holland Hebrew Portugal...
  • Page 14 2D Scanner Setting Manual Latin America Czech Brazil Greek Hungray Turkey Poland Canada(French) Russia...
  • Page 15 2D Scanner Setting Manual Japan ASSIC Albania Canada(Multilingual) Ireland Uzbekistan(cyrillic) Ukraine Kyrgyzstan (Cyrillic) Kazakhstan Belarus...
  • Page 16 2D Scanner Setting Manual Tartar Mongolia(Cyrillic)...
  • Page 17: Keyboard Combination Configuration

    2D Scanner Setting Manual If want to allocate state type is not in the above the bar code, can be the following steps: 1: sweep "keyboard national language configuration” code; 2: sweep the appendix of numeric values in bar code (select the desired digital number decimal countries value);...
  • Page 18 2D Scanner Setting Manual In Germany, France and other countries the keyboard can be had for NumLock to achieve CAPS LOCK function Autocaps via NumLock...
  • Page 19: Character Shift

    2D Scanner Setting Manual 3. Character Shift Keyboard conversion, have the letter content in the output of the bar code, can be configured to output the results to all uppercase or lowercase. For example, if the code contents: ab123dE, if sweep "converted to uppercase" barcode, output the result: AB123DE;...
  • Page 20: Input/Output Configuration

    2D Scanner Setting Manual IV、input/output configuration 1. Power Up Beeper The scanner can be programmed to beep when it’s powered up. If you are using a cordless system, the base can also be programmed to beep when it is powered up. Scan the Off bar code(s) if you don’t want a power up beep.
  • Page 21 2D Scanner Setting Manual click. (This feature has no effect on serial or automatic triggering.) Default = Trigger 。 Click Off. Trigger Click On *Trigger Click Off...
  • Page 22: Good Read

    2D Scanner Setting Manual 4. Good read (1)Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off only turns off the beeperresponse to a good read indication. All error and menu beeps are still audible.
  • Page 23 2D Scanner Setting Manual (3)Beeper Pitch *Medium High...
  • Page 24: Led

    2D Scanner Setting Manual (4)Beep duration * Beep 50ms Beep 20ms 5. LED The LED indicator can be programmed On or Off in response to a good read. Default = On. * LED Good read On LED Good read Off The number of good read beep and LED blink could be several times, and the default is once.
  • Page 25 2D Scanner Setting Manual bar code; 2 sweep accessories digital value bar code (decimal length); 3 sweep "save" 。 Time-out duration setting...
  • Page 26: Read Delay

    2D Scanner Setting Manual 7. Read delay (1)Read delay duration setting This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads.
  • Page 27 2D Scanner Setting Manual User Specified Reread Delay...
  • Page 28: Trigger Modes

    2D Scanner Setting Manual 8. Trigger Modes (1)Manual Trigger modes When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. Two modes are available, Normal and Enhanced. Normal mode offers good scan speed and the longest working ranges (depth of field). Enhanced mode will give you the highest possible scan speed but slightly less range than Normal mode.
  • Page 29 2D Scanner Setting Manual When in Presentation Mode, the LEDs remain dim until a bar code is presented to the scanner, then the aimer turns on and the LEDs turn up to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly. Scan the following bar code to program your scanner for Presentation Mode.
  • Page 30: Continue Scanning Mode

    2D Scanner Setting Manual 9. Continue Scanning Mode When in Continue Scanning Mode, the scanner’s aimer goes out after a short time, but the scan illumination remains on all the time to continuously search for bar codes. Continue Scanning Mode 10.
  • Page 31: Reread Delay

    2D Scanner Setting Manual Presentation Time-Out 12. Read Time-Out When the scanner is in manual trigger mode, if the scanner could not decode the pictures, it will continue decode it until reach the decode time-out. The default decode time-out is 30,000ms. Scan the Read Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save.
  • Page 32: Aimer Light

    2D Scanner Setting Manual 2000ms If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Reread Delay 14.
  • Page 33 2D Scanner Setting Manual LEDs won’t turn on until the delay time is over. Default = Off. Aimer lights Off *Aimer light On Aimer delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken.
  • Page 34: Reverse Barcode Mode

    2D Scanner Setting Manual Total Read Mode-On *Total Read Mode-Off 17. Reverse Barcode mode The reverse barcode is the barcode which space is black and bar is white. In reverse only mode, the scanner could read the reverse barcode. In normal & reverse mode, the scanner could read both normal and reverse barcode, but the scan speed will be a little slow when the barcode print quality is bad.
  • Page 35: Data Editing

    2D Scanner Setting Manual V、Data Editing 1. Prefix & Suffix When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.”...
  • Page 36 2D Scanner Setting Manual Repeat Steps 1-6 to add a prefix or suffix for another symbology. (2)To Clear one or all prefix or suffix You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. If you have been entering prefixes and suffixes for single symbologies, you can use Clear One Prefix (Suffix) to delete a specific character from a symbology.
  • Page 37: Prefix Setting

    2D Scanner Setting Manual Add CR & LF Suffix All Symbologies Add Tab Suffix All Symbologies 2. Prefix Setting The default is no Prefix. Add Prefix Clear On Prefix Clear All Prefix 3. Suffix setting Remark:Suffix default no suffix...
  • Page 38 2D Scanner Setting Manual Add Suffix Clear One Suffix Clear All Suffix...
  • Page 39: Intercharacter And Intermessage Delays

    2D Scanner Setting Manual 4. Intercharacter and Intermessage Delays (1)Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
  • Page 40: Symbologies Configuration

    2D Scanner Setting Manual VI、Symbologies Configuration 1. All Symbologies All Symbologies On(except Post Code) All Symbologies Off 2. Codabar Recall Default Codabar On/Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may...
  • Page 41 2D Scanner Setting Manual either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit Don’t Transmit Codabar Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Maximum Message length Minimum Message length...
  • Page 42: Code39

    2D Scanner Setting Manual 3. Code39 Recall Default Code39 On/Off * On Code39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code39 Check Character...
  • Page 43 2D Scanner Setting Manual or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data.
  • Page 44 2D Scanner Setting Manual Full ASCII On * Full ASCII Off This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 39 bar code with the append trigger character(s), it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger.
  • Page 45: Interleaved 2 Of 5

    2D Scanner Setting Manual 4. Interleaved 2 of 5 Recall Default Interleaved 2 of 5 On/Off Interleaved 2 of 5 Check Character * No Check Character Validate, but Don’t Transmit Validate and Transmit...
  • Page 46 2D Scanner Setting Manual Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 2-80. Minimum Default =2, Maximum Default = 80. Maximum Message length Minimum Message length...
  • Page 47 2D Scanner Setting Manual 5. NEC 2 of 5 Default NEC 2 of 5 setting NEC 2 of 5 On/Off * On NEC 2 of 5 Check Character * No Check Character Validate, but Don’t Transmit Validate and Transmit NEC 2 of 5 Message Length Scan the bar codes below to change the message length.
  • Page 48 2D Scanner Setting Manual Maximum Message length Minimum Message length...
  • Page 49 2D Scanner Setting Manual 6. Code93 Default Code93 setting Code93 On/Off Code93 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Maximum Message length Minimum Message length...
  • Page 50: Straight 2 Of 5 Industrial

    2D Scanner Setting Manual 7. Straight 2 of 5 Industrial Default Straight 2 of 5 setting Straight 2 of 5 Industrial On/Off *Off Straight 2 of 5 Industrial Message length 信息长度 Scan the bar codes below to change the message length. Minimum and Maximum lengths = 4-48.
  • Page 51: Straight 2 Of 5 Iata

    2D Scanner Setting Manual 8. Straight 2 of 5 IATA Default Straight 2 of 5 IATA setting Straight 2 of 5 IATA On/Off *Off Straight 2 of 5 IATA Message length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 4-80.
  • Page 52: Matrix 2 Of 5

    2D Scanner Setting Manual 9. Matrix 2 of 5 Default Matrix 2 of 5 setting Matrix 2 of 5 On/Off *Off Matrix 2 of 5 Message length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 4-80.
  • Page 53: Code 11

    2D Scanner Setting Manual 10. Code 11 Default Code 11 setting Code 11 On/Off *Off Code 11 Check Digit One Check Digit Two Check Digits Code 11 Message length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-80.
  • Page 54 2D Scanner Setting Manual Minimum Message length...
  • Page 55: Code 128

    2D Scanner Setting Manual 11. Code 128 Default Code 128 setting Code 128 On/Off ISBT Code On/Off ISBT Code On *ISBT Code Off Code 128 Message length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-48. Minimum Default = 1, Maximum Default = 48. Maximum Message Length...
  • Page 56 2D Scanner Setting Manual Minimum Message Length...
  • Page 57: Gs1-128

    2D Scanner Setting Manual 12. GS1-128 Default GS1-128 setting GS1-128 On/Off GS1-128 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. Maximum Message Length Minimum Message Length...
  • Page 58: Telepen

    2D Scanner Setting Manual 13. Telepen Default Telepen setting Telepen On/Off *Off Telepen Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Maximum Message Length Minimum Message Length...
  • Page 59: Upc-A

    2D Scanner Setting Manual 14. UPC-A Default UPC-A setting UPC-A On/Off UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On UPC-A Number System The numeric system digit of a U.P.C.
  • Page 60 2D Scanner Setting Manual UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On *5 Digit Addenda Off UPC-A Addenda Required...
  • Page 61 2D Scanner Setting Manual *Not Required UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On.
  • Page 62: Upc-E0

    2D Scanner Setting Manual 15. UPC-E0 Default UPC-E0 setting UPC-E0 On/Off UPC-E0 Expand On/Off * Off UPC-E0 Addenda Required UPC-E0 Addenda Not Required...
  • Page 63 2D Scanner Setting Manual * UPC-E0 Addenda Separator On UPC-E0 Addenda Separator Off...
  • Page 64 2D Scanner Setting Manual UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On *UPC-E0 Leading Zero On UPC-E0 Leading Zero Off 2 Digit Addenda On *2 Digit Addenda Off 5 Digit Addenda On...
  • Page 65 2D Scanner Setting Manual *5 Digit Addenda Off...
  • Page 66: Upc-E1

    2D Scanner Setting Manual 16. UPC-E1 UPC-E1 On/Off *Off...
  • Page 67: Ean/Jan-13

    2D Scanner Setting Manual 17. EAN/JAN-13 Default EAN/JAN-13 setting EAN/JAN-13 On/Off EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.
  • Page 68 2D Scanner Setting Manual 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On *5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda. Default = Not Required. Required *Not Required EAN/JAN-13 Addenda Separator...
  • Page 69 2D Scanner Setting Manual ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. *Off...
  • Page 70: Ean/Jan-8

    2D Scanner Setting Manual 18. EAN/JAN-8 Default EAN/JAN-8 setting EAN/JAN-8 On/Off EAN/JAN-8 Check digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.
  • Page 71 2D Scanner Setting Manual 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On *5 Digit Addenda Off...
  • Page 72 2D Scanner Setting Manual EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda. Default = Not Required. Required *Not Required EAN/JAN-8 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda.
  • Page 73: Msi

    2D Scanner Setting Manual 19. MSI Default MSI setting MSI On/Off *Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit.
  • Page 74 2D Scanner Setting Manual Validate Type 10 and Transmit Validate 2 Type 10 Characters, but Don’t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 10 then Type 11 Character, but Don’t Transmit Validate Type 10 then Type 11 Character and Transmit Disable MSI Check Characters...
  • Page 75 2D Scanner Setting Manual MSI Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Maximum Message Length Minimum Message Length...
  • Page 76: Gs1 Databar Omnidirectional

    2D Scanner Setting Manual 20. GS1 DataBar Omnidirectional Default GSI DataBar Omnidirectional setting GS1 DataBar Omnidirectional On/Off 21. GS1 DataBar Limited 默认配置(919000.) GS1 DataBar Limited On/Off *使能(9190011.) Off(9190010.)
  • Page 77: Gs1 Databar Expanded

    2D Scanner Setting Manual 22. GS1 DataBar Expanded Default GSI DataBar Expanded setting GS1 DataBar Expanded On/Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-1) for additional information. Minimum and Maximum lengths = 4-74.
  • Page 78: Pdf417

    2D Scanner Setting Manual 23. PDF417 Default PDF417 setting PDF417 On/Off PDF417 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Maximum Message Length Minimum Message Length...
  • Page 79: Micropdf417

    2D Scanner Setting Manual 24. MicroPDF417 Default Micro PDF417 setting MicroPDF417 On/Off *Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Maximum Message Length Minimum Message Length...
  • Page 80: Gs1 Composite Codes

    2D Scanner Setting Manual 25. GS1 Composite Codes Default GS1 Composite setting GS1 Composite Codes On/Off *Off UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Version Off.
  • Page 81 2D Scanner Setting Manual Maximum Message Length Minimum Message Length...
  • Page 82: Tcif Linked Code 39 (Tlc39)

    2D Scanner Setting Manual 26. TCIF Linked Code 39 (TLC39) TCIF Linked Code 39 On/Off 27. QR Code Default QR setting QR Code On/Off QR Code Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-7089.
  • Page 83 2D Scanner Setting Manual Maximum Message Length Minimum Message Length...
  • Page 84: Data Matrix Code

    2D Scanner Setting Manual 28. Data Matrix Code Default Data Matrix setting Data Matrix CodeOn.Off Data Matrix Code Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Maximum Message Length Minimum Message Length...
  • Page 85: Maxicode

    2D Scanner Setting Manual 29. MaxiCode Default MaxiCode setting MaxiCode On/Off *Off MaxiCode Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150. Maximum Message Length Minimum Message Length...
  • Page 86: Aztec Code

    2D Scanner Setting Manual 30. Aztec Code Default Aztec Code setting Aztec Code On/Off Aztec Code Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832. Maximum Message Length) Minimum Message Length...
  • Page 87: Han Xin Code

    2D Scanner Setting Manual 31. Han Xin Code Default Han Xin Code setting Han Xin Code On/Off *Off Han Xin Code Message Length 。 Scan the bar codes below to change the message length. Minimum and Maximum lengths = 1-7833. Minimum Default = 1, Maximum Default = 7833. Maximum Message Length Minimum Message Length...
  • Page 88: Postal Codes

    2D Scanner Setting Manual 32. Postal Codes he following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code election can be active at a time. If you scan a second 2D postal code selection, the first selection is overwritten. Default = 2D Postal Codes Off.
  • Page 89 2D Scanner Setting Manual Maximum Message Length Minimum Message Length (2)Korea Post Default Korea Post setting Korea Post On/Off *Off Korea Post Message Length Scan the bar codes below to change the message length. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
  • Page 90: Add Prefix

    2D Scanner Setting Manual Maximum Message Length Maximum Message Length Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Default = Don’t Transmit. Transmit Check Digit *Don’t Transmit Check Digit 4.1Add Prefix Generate Configurtion Barcode...
  • Page 91: Add Sufix

    2D Scanner Setting Manual added, plase note that punctuation mark . is requried. For examaple, if prefix A is going to be added, following is the commad ^38890029941. If prefixs ABC are going to be added, command will be following: ^388900299414243 Scan the barcde generated in the step 3, then scan 800002.
  • Page 92 2D Scanner Setting Manual Type: Configuration barcde is a Code128 barcode. Command: ^388800299 + ASCII Code(s). ^388800299 the fix part of the command ASCII Code(s). ASCII codes(s) of prefix(s) that will be added, plase note that punctuation mark . is requried. For examaple, if prefix A is going to be added, following is the commad ^38880029941.
  • Page 93 2D Scanner Setting Manual...
  • Page 94: Appendix 1: Programming Digit Chart

    Appendix 1: Programming Digit Chart Appendix 1:Programming Digit Chart...
  • Page 95 Appendix 1: Programming Digit Chart Save Cancel...
  • Page 96: Appendix 2: Ascii Chart

    Appendix 2: ASCII Chart Appendix 2:ASCII Chart Decimal Dexadecimal Character NULL START OF HEADING (SOH) START OF TEXT (STX) END OF TEXT (ETX) END OF TRANSMISSION (EOT) END OF QUERY (ENQ) ACKNOWLEDGE (ACK) BEEP (BEL) BACKSPACE (BS) HORIZONTAL TAB (HT) LINE FEED (LF) VERTICAL TAB (VT) FF (FORM FEED)
  • Page 97 Appendix 2: ASCII Chart DEVICE CONTROL 2 (DC2) DEVICE CONTROL 3 (DC3) DEVICE CONTROL 4 (DC4) NEGATIVE ACKNOWLEDGE-MENT (NAK) SYNCHRONIZE (SYN) END OF TRANSMISSION BLOCK (ETB) END OF MEDIUM (EM) SUBSTITUTE (SUB) ESCAPE (ESC) FILE SEPARATOR (FS) RIGHT ARROW GROUP SEPARATOR (GS) LEFT ARROW Decimal Dexadecimal Character...
  • Page 98 Appendix 2: ASCII Chart &...
  • Page 99 Appendix 2: ASCII Chart < Decimal Dexadecimal Character >...
  • Page 100 Appendix 2: ASCII Chart Decimal Dexadecimal Character...
  • Page 101 Appendix 2: ASCII Chart...
  • Page 102 Appendix 2: ASCII Chart Decimal Dexadecimal Character <DEL>...
  • Page 103: Appendix 3:Symbologies Chart

    Appendix 3: Symbologies Chart Appendix 3:Symbologies Chart AIM ID CODE CODE Symbologies AIM ID Setting IDHex All Symbologies Code128 0,1,2,4 GS1-128 EAN-13 EAN-13 with Add-On EAN-13 with Extended Coupon Code EAN-8 EAN-8 with Add-On Matrix 2 of 5 Code49 0,1,2,4 Code 32 <3C Code 39...
  • Page 104 Appendix 3: Symbologies Chart China Post Han Xin Codebar Codablock A 0,1,4,5,6 Codablock F 0,1,4,5,6 Code 11 Data Matrix Australian Post Aztec Code 0-9,A-C GS1 Composite GS1 DataBar AIM ID CODE CODE Symbologies AIM ID Setting IDHex InfoMail Intelligent Mail Barcode Interleaved 2 of 5 0,1,3...
  • Page 105 Appendix 3: Symbologies Chart Korea Post MaxiCode MicroPDF417 NEC 2 of 5 OCR MICR (E 13 B) OCR SEMI Font OCR-A OCR-B PDF417 Planet Code Postal-4i Postnet Straight 2 of 5 IATA 0,1,3 Straight 2 of 5 Industrial TCIF Linked Code 39 (TLC39) Telepen UPC-A...
  • Page 106 Appendix 3: Symbologies Chart...
  • Page 107 Appendix 3: Symbologies Chart AIM ID CODE CODE Symbologies AIM ID Setting IDHex UPC-A with Extended Coupon Code UPC-E UPC-E with Add-On UPC-E1...

Table of Contents