Instrument Certificate Date: Model : ZIVE SP2 Serial No.: End-user: AC Power Line: 100VAC-240VAC 50/60Hz Installation date: Warranty Period: One Year Option V range I range +/-10V Corrosion +/-1V 200mA ElectroAnalysis +/-100mV 20mA Battery 200uA 20uA 200nA 20nA 200pA 20pA...
Page 4
ZIVE SP2 Instruction manual This manual has to be read carefully before switching on the instrument. The Instructions must be followed strictly. Non-observance of these instructions can lead to the loss of right to claim for damages or guarantee. Manufactured by WonATech Co,.
Page 5
ZIVE SP2 Instruction manual Take the time to read this License Agreement prior to opening this package, because by opening the package, you accept the terms and conditions of this License Agreement. Likewise, if you do not accept the terms of this agreement, do not open this package.
Page 6
ZIVE SP2 Instruction manual Limited Warranty WonATech warrants to the original user of this product that it shall be free of defects resulting from faulty manufacture of the product or its components for a period of one year from the date of shipment.
Do not place any obstacle preventing air flow at bottom or the side of the unit ZIVE SP2 should only be used with the supplied cell cable. If you use a custom made cell cable, it is likely to create noisy data.
ZIVE SP2 Instruction manual A service contract that extends the hardware warranty is available at an additional charge. Please contact your local representative or distributor. 4. Software upgrade and general information The latest version of firmware and software upgrade is available at http://www.zivelab.com.
Failure to do so may create a safety hazard. 2. Safety You must use earth grounded AC power source. You should use AC/DC adapter which supplied with ZIVE SP2. Do not use other power source other than that supplied with the ZIVE SP2. - 12 -...
ZIVE SP2 Instruction manual There is screw part on power connector, you must connect adapter’s screw cap to this screw part. Do not locate any obstacles which will prevent air flow at bottom and side of the ZIVE SP2. 3. USB port PC must have usb2.0 high speed port and needs USB port number per device...
ZIVE SP2 Instruction manual Chapter 3. Reference ZIVE SP2 generates sine wave using fast DAC(50MHz) with DDS and DSP calculate the impedance in accordance with the block diagram below. Output signal has x1, x0.1 and x0.01 gain. Current & voltage input signal has x1, x10 and x100 gain.
ZIVE SP2 Instruction manual Chapter4. Installation 1. Rear Panel Internal FRA included FPGA/DSP control Plug-In Type Busy LED communication Power switch RUN LED Temperature measurement (K type) LAN port thermocouple (option) USB port Cell port : Working, reference, counter, working sense, ground Power connector Misc.
ZIVE SP2 Instruction manual 3. Front panel LCD There is a front panel LCD that displays relevent test information. Its function will be automatically change depending on the applied test mode (impedance test or DC test). Asteristic or heart mark: blinking 1) DC data monitoring...
Current range 4. Checking points Power line cables (PC, Monitor, Zive SP2, Printer etc.) should be for earth ground No fault on system information of Windows 2000/XP/Vista/7/8 control panel No virus in Software inside PC Test ZIVE SP2 using dummy cell.
, it means that communication between PC and ZIVE SP2 is disconnected. ZIVE SP2 can save the data file in PC in real time but for fast sampling rate(including burst mode), data stocking speed in ZIVE SP2 is faster than transfer rate to PC. So after finishing the experiment, data transferring from ZIVE SP2 to PC may continue for some time.
Each channel is plug and play type. Easy firmware upgrade It is possible to extend multichannel system using several set of ZIVE SP2 using USB hub. If there is PC power failure or USB cable is unplugged by accident, the experiment keeps going and you can tranfer data from ZIVE SP2 memory any time.
ZIVE SP2 Instruction manual If you input wrong license code, you can see the following message You MUST click “Save channel info”. After above process, you MUST turn off ZIVE SP and turn it on. License code comes from ZIVE SP serial number. So if you try to input license code for other ZIVE ...
Page 23
ZIVE SP2 Instruction manual Click Device utility icon on tool bar Select device number on channel 2 Click “Save Ch. Setting” button Multichannel system is ready. Note: If each SP has different license, each license will work only for its SP.
ZIVE SP2 Instruction manual Chapter5. Update firmware When you install new version smart manager software, this software will detect firmware update requirement. If it require firmware update, you can update firmware package in smart manager software. Please refer to Smart Manager operation manual.
If the progress bar stops, it is mainly due to lack of resources in the computer. Close other application programs and turn-off /turn on the instrument and try to update firmware again. Do not turn off during firmware upgrade. After Firmware upgrade, you must turn off ZIVE SP2 and turn it on If PC was not connected to instruments, the following message will be displayed..
ZIVE SP2 Instruction manual Click “Select firmware file “button and select firmware package(*.sfw), the you can see file information at “ USB firmware” at bottom side. The information of “Chip Information” section is for firmware information inside of instruments. Please compare with two dates and only if target firmware’s date is newer, try to update the firmware.
ZIVE SP2 Instruction manual C. DSP firmware update To update dsp firmware; Select channel number. Click “Select firmware file “button as the above and select firmware package(*.sfw), the you can see file information at “ file information” at bottom side. The information of “Chip Information” section is for firmware information inside of instruments.
Reference: White connector Counter: Red connector ZIVE SP2 was shipped with standard 1meter shielded cell cable. Cell connector is Dsub type and other side has 5 banana ended plugs with removable alligator clips. 25pin Dsub male connector of standard cell cable connects to SP2’s rear panel 25pin Dsub female connector.
ZIVE SP2 Instruction manual 1. General connection (3 electrodes connection) Red colored lead to counter electrode White colored lead to reference electrode Green colored lead to working electrode Blue colored lead to working electrode Working Counter:...
ZIVE SP2 Instruction manual 3. ZRA connection (2 working electrodes connection) AuxV1(-) lead to reference electrode Green colored lead to working1 electrode Blue colored lead to working1 electrode AuxV1(+) lead to working1 electrode White colored lead : Working2 electrode ...
ZIVE SP2 Instruction manual Appendix 1. Specification Main system PC communication USB2.0 High Speed Line voltage 100-240VAC, 50/60Hz, 1Amp Power adapter 24V@2.5A Size/weight 113X305.7X196mm(W*D*H) / 3.2kg Max output power 24Watt System Cell cable 1meter shielded type (Standard) Working, reference, counter,...
Page 32
ZIVE SP2 Instruction manual Electrometer Max input voltage ±10V Input impedance 2x10 Ω||4.5pF Bandwidth >22MHz CMRR >114dB EIS(Internal FRA) for system Frequency range 10uHz ~ 2MHz Frequency accuracy 0.01% Frequency resolution 5000/decade Amplitude 0.1mV ~ 5V rms (Potentiostatic) 0.1 ~ 70%(Galvanostatic)
Page 35
ZIVE SP2 Instruction manual Power switch USB port ROM switch Power connector ROM switch direction: write enable ROM switch direction: write protected - 35 -...