o n t e n t s 1 Safety regulations and notes ................4 2 General information ..................5 Packing contents ................5 Meaning of the symbols used ............... 5 Technical data..................6 Description ..................7 Software query .................. 8 3 Assembly ......................9 Installing the cassette ................9 EMC regulations ................
Page 3
Signal source ................27 Switching the IP address off or on ..........28 Transmission protocol ..............28 Port number ................28 Input IP addresses ............... 29 Station filter ................29 Hints about the service IDs ............30 Manually selection ..............31 Transport stream / ORGNET-ID ............
a f e t y r e g u l a t i o n s a n d n o t e s • Assembly, installation and servicing should be carried out by authorised electricians. • Switch off the operating voltage of the system before beginning with assem- bly or service work or pull out the mains plug.
2.3 t e C h n i C a l data The devices meet the following EU directives: 2011/65/EU, 2014/30/EU, 2014/35/EU The product fulfils the guidelines and standards for CE labelling (page 49). Unless otherwise noted all values are specified as "typical". LAN interface Standard: ............
2.4 d es C r i P t i o n The cassette is a 5 to 1 multiplexer. It converts 5 ASI/SPTS/MPTS input channels into one ASI/MPTS output channel. Each input transport stream can be fed in selectively via each one ASI input or the LAN interface (five input IP addresses). The fed in transport streams can be edited individually and will be combined into one transport stream in the TPS module.
To operate this cassette the software version of the control unit must be "V 45" or higher. You can find the current operating software for the control unit and the cassette, the software "BE-Flash" and the current assembly instructions on the website "www.mygss.eu". The cassette is intended for use in the PROFI-LINE head-end stations.
s s e m b l y 3.1 i n s ta l l i n g t h e C a s s e t t e – Ensure the head-end station is mounted so it will not be able to vibrate. Avoid, for example, mounting the head-end station onto a lift shaft or any other wall or floor construction that vibrates in a similar way.
3.2 emC r e g u l at i o n s To comply with the current EMC regulations, it is necessary to connect the lines leading in and out of the head-end station using cable terminals. When mounting the cassette in a head-end station which is installed in a 19" cabinet, make sure the connections leading in and out for the 19" cabinet are made using cable terminals. The attenuation of shielding of the connection lines for ASI and antenna must meet the requirements for "Class A". CLASS • Insert the required number of cable terminals in the openings provided in the head-end station or in the 19" cabinet. Tighten the nuts on the cable terminals until the teeth on the lock washer have penetrated the exterior coating and a good connection is made between the hous- ing and cable terminals.
3.3 C a s s e t t e ov e rv i e w Status LED of the LAN interface (data transfer) LAN socket Status LED of the LAN interface (network connection) ASI output ASI input 5 Status LED ASI input 5 ASI input 4 Status LED ASI input 4 ASI input 3...
r o g r a m m i n g 5.1 P ro g r a m m i n g Pro C e d u r e Ein / On Bedienhinweise Operating Hints BE–Remote V 45 "blättert" Menüs vorwärts. scrolls forward through the menu.
Page 14
0xxx nur bei Auswahl "ASI" only with selection "ASI" Bx 4 OUTPUT Bx 4 ASI RATE ◀ ▶ ▶ => 108000 KBits ASI/LAN 188 / 204 Bx 4 ASI OPTION ◀ ▶ positiv / negativ, 188 pos. cont. positive / negative kontinuierlich / burst, continuous / burst nur bei Auswahl "LAN"...
Page 15
1234 0 … 65535 IN 1 IP-INPUT ◀ ▶ 227. nicht bei MUX-MODE "transparent" not with MUX-MODE "transparent" IN 1 FILTER first / all / cascaded / manual nur bei Auswahl "manual" only with selection "manual" IN 1 ± 001/016 ◀...
5.2 P r o g r a m m i n g t h e C a s s e t t e —> Pressing the button for longer than 2 seconds cancels the programming procedure. This takes you back to the program item "Selecting the cassette"...
• Press the button. —> The "Ethernet parameters" – "ETHERNET" main menu is activated. t h e r n e t Pa r a m e t e rs In this menu you specify whether the Ethernet parameters for the cassette are entered automatically by a connected server ("DHCP"), or whether you want to enter them manually ("stat").
• Use the buttons to place the cursor under the digit of the IP address displayed to be set and use to set the desired IP address. • Press the button. IP-MASK —> The "Address range" – " " sub menu is activated. d d r es s r a n g e In this menu you define the address range for the cassettes connected to the...
udP P o r t The UDP port setting is required if the cassette shall be controlled via LAN and the standard port 60000 can not be used. Bx 4 UDP-PORT 60000 • Use the buttons to place the cursor under the digit of the port number displayed to be set and use to set the desired port number ("0"...
"manual" or "transparent" setting: —> The "Output parameter" – "OUTPUT" menu is activated (page 21). "fixed" setting: —> The "SID standard" – "SID-NORM" menu is activated. sid s ta n da r d —> This menu is only displayed if "fixed" is selected in menu "MUX- MODE".
SID 201 —> SID 12201 … —> Adding an offset will avoid to get the same SID twice if several PADA 5100 are used "in parallel" (and not cascaded). • Use the buttons to enter the desired offset. • Press the button.
• Press the button. —> If "ASI" is selected, the "ASI transmission rate" – "ASI RATE" sub- menu is activated. —> If "LAN" is selected, the "LAN datarate" – "LAN RATE" submenu is activated (page 23). asi t r a n s m i s s i o n r at e In this menu you set the output transmission rate for the ASI component con- nected.
—> Setting "cont." The data packets of the user data are spaced out evenly in the trans- port stream. —> Setting "burst" The data packets of the user data are collected to a great data packet in the transport stream. •...
iP u t P u t a d d r es s In this menu you set the IP address for the IP output. OUT-IP 227. —> Use an IP address of the multicast range (224.5.0.0 … 231.255.255.255 e.g. 227.40.50.x). •...
—> The "Switching the IP address off or on, transmission protocol, port number" – "MODE / PORT" submenu is activated. iP w i tC h i n g t h e a d d r es s o f f r a n s m i s s i o n P r oto C o l o r t n u m b e r...
ua n t i t y data PaC k e t s o rwa r d e r r o r C o r r e C t i o n r a n s m i s s i o n C h a n n e l In this menu you set the quantity of the data packets to be transmitted, the forward error correction FEC and the transmission channel.
n P u t Pa r a m e t e rs In this menu you select the input, for which you would like to set the input pa- rameters in the submenus. Bx 4 INPUT 1 LAN OK => —>...
—> If "ASI" is selected, the "Station filter" – "FILTER" submenu is acti- vated (page 29). —> If "LAN" is selected, the "Switching the IP address off or on, Trans- mission protocol, Port number" – "IN x MODE / PORT" submenu is activated.
—> The "Input IP addresses" – "IN x IP-INPUT" submenu is activated. iP n P u t a d d r e s s es In this menu you set the IP address for the IP input selected. IN 1 IP-INPUT 227.
—> "all" - all stations are used. "cascaded" - setting for the "downstreamed" PADA 5100 when using several PADA 5100 cascaded – observe the following hints about the service IDs (SIDs) as well as chapter "cascading" (page 37). "first" - only the first station of the transport stream (PAT) is used.
• Press the button. —> Is "all", "cascaded" or "first" selected, you will be returned to the "Input parameters" – "INPUT" main menu (page 27). —> Is "manual" selected, The "Manually selection" – "IN x 00x/00y" submenu is activated. a n ua l ly s e l e C t i o n —>...
Page 32
Further possible terms displayed: "RA" Radio channel type For radio stations, the background of the screen of the connected TV or test receiver is darkened. "—" The currently selected station is deactivated. "HD" HD reception —> If a service number (e.g. "131") appears instead of "TV" or "RA", this indicates that an unnamed station or an undefined data stream is being received.
—> This menu is not displayed, if "transparent" is selected in menu "Multiplex mode" (page 19). Is a NIT generated via the remote control software PSW 1000 (from SW V39 on), the PADA 5100 is included. In this menu the NIT can be switched on or off. Bx 2 •...
• Press the button. —> The "Refresh the tables" – "REFRESH" main menu is activated. e f r es h t h e ta b l es —> This menu is not displayed, if "transparent" is selected in menu "Multiplex mode" (page 19). Herein you select when the tables are refreshed.
u t P u t data r at e In this menu the current output data rate is displayed. Bx 4 DATARATE 087/180 —> "087" - current data rate. "180" - maximum data rate —> The maximum Data rate depends on the used/available output: –...
aC to ry r es e t In this menu you can reset all settings to the factory defaults. Bx 4 FACTORY Bx 4 FACTORY ▶ Defaults => STORE => M • Press the button. —> The submenu "FACTORY STORE" is invoked. —>...
" s ta n da r d If several PADA 5100 are cascaded, at the "downstream" cassette (cassette 6 of the example) the station filter (page 29) must be set to "cascaded". Cascading, for example, is used to combine many transport streams each containing one service to one transport stream.
Page 38
—> At Cascading the SID-Offset (page 21) of the "upstream" cassettes must be set to "0xxx", so that the static SID assignment of the "downstream" cassette works. Table for "static" SID assignment at station filter setting "cascaded" Input If more than one services are present at one input of Input SID SID at the output "upstream"...
" s ta n da r d If several PADA 5100 are cascaded, at the "downstream" cassette (cassette 6 of the example) the station filter (page 29) must be set to "cascaded". Cascading, for example, is used to combine many transport streams each containing one service to one transport stream.
Page 40
—> At Cascading the SID-Range (page 21) of the "upstream" cassettes must be set to "0xxx", so that the static SID assignment of the "downstream" cassette works. Table for "static" SID assignment at station filter setting "cascaded" 16 Bit SID Input If more than one services are present at one input of Input SID SID at the output "upstream"...
Psw 1000 o P t i o n s All the settings that have been described above, can be done via the PSW 1000 more comfortably in menus "Settings" and "Filter". Detailed SID/PID settings are possible via menu "Filter". —> For basic operations observe the operating instruction of the PSW 1000.
Page 42
—> The function/buttons which are not described in that chapter, are basic operations. For that please observe the operating instruction of the PSW 1000. The menu contains five submenus (tab "Line A"…"Line E"). In the following figures the input fields are assigned to the corresponding menus of the control unit.
Page 43
Section Output ASI Bx 4 OUTPUT Bx 4 ASI RATE Bx 4 ASI OPTION => 108000 KBits 188 pos. cont. Bx 4 LAN CHECK Bx 4 TS/ONID Bx 4 enable 0x0001,0100 Section Output LAN Bx 4 LAN CHECK Bx 4 OUTPUT Bx 4 PKTS / FEC...
- e e t t i n gs w i n d ow d i t m e n u Filter The function Filter is described from Page 45 on. Export cassette and filter settings With this menu item you can export the cassette and filter settings. •...
6.2 m e n u i lt e r Herein you can perform the settings of "Multiplex mode", "SID standard", "SID offset", "Refreshing the tables" and the station filter. In the multiplex mode "manual" you can modify the SIDs/table PIDs manually. —>...
" " u lt i P l e x m o d e m a n ua l Herein you can filter out stations (services) and manually rename SIDs/PIDs. —> All stations (services) are deactivated and, if required, must be reac- tivated by the check boxes.
Page 47
• Enter the new value and click on button "OK". —> In section "Input" the old and the new value is displayed: "old value" => "new value" —> In section "Overview filter settings" all manually modified/deacti- vated PIDs are listed. —>...
i n a l Pro C e d u res After installing the head-end station, upgrading accessories or installing cas- settes it is necessary to tighten all cable connections, cable terminals and cover screws in order to maintain compliance with current EMC regulations securely. • Securely tighten the cable bolted connections using an appropriate open- ended spanner. • Mount the front cover (see assembly instructions of the head-end station). - 48 - PADA 5100...
Need help?
Do you have a question about the PADA 5100 and is the answer not in the manual?