Summary of Contents for Nordson EFD 741MD-SS Series
Page 1
Europe: 0800 585733 or +44 (0) 1582 666334 Asia: +86 (21) 5854 2345 technical@efd-inc.com www.efd-inc.com Barrel adapter assembly Introduction The 741MD-SS Series is simple to use and will operate many millions of cycles without maintenance. Stroke reference ring The 741MD-SS is a pneumatically operated, Control...
Page 2
To exhaust To pressurize Installation Prior to installing this valve, please read the associated reservoir and valve controller operating instructions to become familiar with the operation of all components of the dispensing system. Mount valve with an EFD universal valve mount (#7002VM) or other fixture.
Page 3
How the Valve Operates Input air pressure at 70 psi (4.8 bar) retracts The amount of fluid dispensed the piston and needle from the needle seat will depend on the time the valve ➀ ➀ in the dispensing tip , permitting fluid flow is open, fluid reservoir pressure, ➁...
Calibration Feature Specifications The stroke control reference ring of each 741MD-SS valve is factory calibrated to the zero position. Slight internal variations in General dispensing tips may require the stroke control to be recalibrated when tips are changed. To do so: Size: 127.5 mm length x 26.9 mm diameter 1.