Dr. Trust ECG PEN User Instructions

Smart portable ecg pen

Advertisement

Quick Links

12. ABOUT US
Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers
with the latest medical inventions with an objective to promote good health and wellness
all around the world. All the medical devices and health monitors provided by Dr Trust are
supported by accurate, latest and ground breaking technologies, innovated at our
headquarters in NY, USA. All our products adhere to the most stringent CE and FDA
guidelines and are strongly recommended by doctors and health practitioners. Our
products are designed in the utmost exemplary ways to ensure that their accuracy and
convenience are unrivalled. The ease of their use and operation makes them even more
suitable for users of all age groups.
Dr Trust strives to enhance the quality of lifestyle by providing with the most trusted and
innovative health care and wellness products. Being a renowned global leader in health
care products, Dr Trust ensures that our technically e cient team works dynamically and
tirelessly to provide the best of the medical devices to our clients. The products that we
have to o er are suitably designed for use at homes, laboratories and hospitals.
Our ground breaking solutions allow you to monitor your health in the easiest ways
possible. In today's era when all of our lives are too hassled to handle, it becomes a bit
di cult to pay attention to our health. But it has now become easier with the coming of the
monitoring devices which can be conveniently used at homes and even on the go.
We bring to you a variety of best self medical devices, trusted and used by Doctors,
medical professionals and home users all over the world.
26
SMART PORTABLE
ECG PEN
Thank you for purchasing Dr. Trust Smart Portable ECG Pen. Please read the
instructions before use.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECG PEN and is the answer not in the manual?

Questions and answers

Summary of Contents for Dr. Trust ECG PEN

  • Page 1 We bring to you a variety of best self medical devices, trusted and used by Doctors, medical professionals and home users all over the world. Thank you for purchasing Dr. Trust Smart Portable ECG Pen. Please read the instructions before use.
  • Page 2: Table Of Contents

    6. Taking Measurement Operation Procedure Common Wrong Operations 7. Result Display Measurement Results Reviewing Results on ECG Pen 8. iBP Monitor APP 2. GENERAL NOTES System Requirements Installation and Connection 1. This is an Electrocardiogram (ECG) device that provides referential data that could be taken into Application Interface consideration by medical professionals.
  • Page 3: Important Safety Notes

    Do not use this device with a brillator.  The ECG Pen can take up to 500+ measurements with two new coin-typed batteries and keep Do not submerge (or immerse) the device in water or liquid. Do not clean the device with acetone, records of 36 measurements.
  • Page 4: Components

    5. PREPARATION BEFORE TAKING MEASUREMENT 4. Bottom Electrode Battery Installation To charge your ECG Pen, please follow the steps below: 1. Remove the battery cover by inserting the tip of y Lcd display 2. Follow the +(positive) and -(negative) polarities indicated on the battery compartment.
  • Page 5: Things To Know Before Taking Measurement

    Things to Know Before Taking Measurement Measurement method C o ers maximum comfort, but o ers a much lower measurement stability than To assure accurate measurement, please observe the following: methods A or B. Make sure that electrodes are directly in contact with your skin. Press the on/ o button for about three seconds to turn the device on.
  • Page 6 Lightly press the electrode against your chest until you hear or feel a click. Measurement “left hand–right hand” method C Important: Do not pr our skin. (approximately corresponds to “lead 1”) Measurement chest” Place y wo upper electrodes on the device. (approximately corresponds to “lead 3”) method B our left hand on the lower electrode.
  • Page 7: Common Wrong Operations

    : Fast Heart Rate (>100 bpm)  Measuring over/through clothing. : Paused Heart beat (pause>2 s) : Irregular Rhythm (Disrupted Rhythm)  Pressing wrong side of ECG Pen against the chest. : Abnormal Waveform (Altered Waveform) Please note that if the displayed heart rate is , it indicates ECG signals are unstable or weak.
  • Page 8: Reviewing Results On Ecg Pen

    Application Interface number of stored records. You can connect IBP monitor app with your Dr Trust ECG Pen devices using Bluetooth 4.0. It helps in providing real-time display of ECG and blood pressure measurements. The app also automatically stores 3. By pressing the button repeatedly, the result will be shown in a cyclic order.
  • Page 9: Cleaning And Maintenance

    “Device settings”. You can also obtain the device information from here when your Dr. Trust device is in connection with your smart phone or your Measurement result shows...
  • Page 10: Tions

    12. EMC INFORMATION ■ Device ID is not Problems of data exchanging for I f the device is discovered tion. successfully, there will be a blank displayed on the box in on the box, then click on the blank to manually link the device “iBP Monitor APP.
  • Page 12 RF transmitters, an electromagnetic site survey should be considered. If the measured strength in the location in which the Dr.Trust ECG Pen is used exceeds the applicable RF compliance level above, the Dr.Trust ECG Pen should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Dr.Trust ECG Pen.
  • Page 13 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.