Alarm system for elevators compliant with the european standard en 81-28:2018
Hide thumbs Also See for HELPY:

Advertisement

Alarm system for elevators
compliant with the European Standard
EN 81-28:2018
HELPY CONTROLLER
QUICK GUIDE
05/04/2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HELPY and is the answer not in the manual?

Questions and answers

Summary of Contents for Esse-ti HELPY

  • Page 1 Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY CONTROLLER QUICK GUIDE 05/04/2019...
  • Page 2 DESCRIPTION Autodialer specifically designed for installation on elevator controller. Connectors for optional PSTN-line board LEDs Reset pushbutton Micro USB A/B port for PC connection Serial port for PC connection RJ45 connector for GSM Satellite Terminal blocks Connector for machine room speaker unit 12 V backup battery connector Page 2 DESCRIPTION...
  • Page 3: Terminal Blocks

    : can be connected to a block –, to the block +12 V Out or to an external reference : allows to connect voltage free contact (NO or NC) or powered contacts Optional PSTN-line board PSTN-line or universal GSM gateway input Ground terminal HELPY CONTROLLER LED signalling device status GREEN LED signalling GSM Satellite signal strength WHITE...
  • Page 4: Connecting The Telephone Line

    A GSM SIM card is required. Do not use 3G/UMTS or 4G/LTE SIM cards. ATTENTION It is not required to remove the PIN code prior to the use of the Helpy Controller. The PIN code can be entered, if necessary, by setting parameter 282. ATTENTION In order to avoid damage, never power up the device without having first installed the antenna.
  • Page 5 Connecting the GSM satellite  Connect the RJ45 connector of the GSM satellite to the RJ45 connector of the Helpy Controller by means of the supplied cable. PSTN line or universal GSM gateway  Insert the optional PSTN-line board in the dedicated connectors (A in the picture at page 2) ...
  • Page 6 CONNECTING THE SPEAKER UNITS It is possible to connect to the Helpy Controller up to 16 independent 2W speaker units by means of the 2-wire bus (4 units with direct power supply from the bus and 12 with separate power supply).
  • Page 7 Given alarm indicator light (light negative pole) AL1— Alarm input Auxiliary input / Alarm input / Filter input AL1+ Alarm input BUS— Bus for connecting Helpy Controller BUS+ Bus for connecting Helpy Controller only for some models CONNECTING THE SPEAKER UNITS Page 7...
  • Page 8: Dip Switch

    Terminal blocks for connecting passive speaker unit ALT2 Output for connecting loudspeaker of passive speaker unit MIC2 Input for connecting microphone of passive speaker unit or single microphone — Negative Microphone DIP switch The DIP switch allows to assign an ID (01~16) to each 2W speaker unit connected to the bus.
  • Page 9 CONNECTING THE EMERGENCY CALL BUTTONS It is possible to connect external pushbuttons (voltage free contact pushbuttons or powered pushbuttons) to 2W speaker units without built-in pushbutton.  Connect, following one of the diagrams shown below, the external pushbutton to the 2W speaker unit. CONNECTING THE EMERGENCY CALL BUTTONS Page 9...
  • Page 10 CONNECTING THE INDICATOR LIGHTS The GIVEN ALARM INDICATOR LIGHT (yellow) switches on after pressing the emergency button to indicate the beginning of the alarm procedure. The RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered. Some 2W speaker unit models come with built-in indicator lights. It is also possible to connect external indicator lights.
  • Page 11: Other Connections

    OTHER CONNECTIONS ONNECTING THE LOCAL TELEPHONE  Connect the local telephone (for programming and managing the device) to TEL and – terminals (irrespective of the polarity). ONNECTING THE FILTER INPUT  Connect the filter contact as per one of the modes shown in the table: C TERMINAL FILTER CONTACT CONNECTED TO:...
  • Page 12: Wiring Diagrams

    WIRING DIAGRAMS IRING DIAGRAM WITH SPEAKER UNITS IN THE CAR AND IN THE PIT AND PASSIVE SPEAKER UNIT ON CAR TOP Page 12 WIRING DIAGRAMS...
  • Page 13 IRING DIAGRAM WITH LANDING FLOORS WIRING DIAGRAMS Page 13...
  • Page 14 MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING  Access to programming: lift the local telephone handset and dial The programming activated message will be heard.  Program a telephone number for the emergency-call alarm: dial <telephone number>  Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial and, after the “Correct”...
  • Page 15  Speak with the trapped person. mode: handsfree connection by “Handsfree activation” code  Answer by the called party. The voice messages will be heard.  Press to speak with the trapped person. mode: automatic handsfree connection without messages  Answer by the called party. ...
  • Page 16 * <Password> #. Pressing longer (10 seconds) Allows to reset the device. By pressing longer, the Helpy Controller will be re-started with no need to disconnect the power supply. Note: it is also possible to reset the device through the code 995*0#.
  • Page 17: Basic Programming

    < INSTALLER or OPERATOR PASSWORD > EXITING THE PROGRAMMING (factory default: SOURCE RECEIVER emergency- call button battery USER alarms * periodic automatic test ESSE-TI call * … (X..X = 2W speaker telephone TELEPHONE unit connection (position number, NUMBERS failure alarm from 01 to max.
  • Page 18 BASIC PROGRAMMING TYPE OF PSTN line or universal GSM gateway TELEPHONE LINE (INST) GSM Satellite WEEKDAY SUNDAY MONDAY TUESDAY DATE (INST) (dd) (mm) (yy) WEDNESDAY THURSDAY FRIDAY SATURDAY TIME (hhmm; from 0000 to 2359) (INST) identification message RECORD (max. 25s ) MESSAGES (record) (hang up)
  • Page 19 AUTOMATIC TEST automatic test disabled DATA Automatic (INST) automatic test enabled (EN 81-28:2018) test alarm automatic test enabled (EN 81-28:2004) Make a test call manually PROTOCOLS Esse-ti IDENTIFICATION … (identification code) CODE P100 (INST) SPEAKER UNITS loudspeaker microphone VOLUME speaker unit ID...
  • Page 20: Advanced Programming

    Advanced programming ADVANCED PROGRAMMING CHANGE THE INSTALLER … PASSWORD “0” (old) (new) (new) (INST) CHANGE THE OPERATOR … PASSWORD “1” (old) (new) (new) (INST) EMERGENCY CALL BUTTONS DELAY (seconds, from 3 to 9) (INST) IN1 INPUT IN1 = filter SETTING (INST) IN1 = reset 2W SPEAKER...
  • Page 21 ADVANCED PROGRAMMING FILTER INPUT normally closed NORMALLY CLOSED/OPEN (INST/OPER) normally open FILTER BYPASS (seconds, from 15 to 30) (INST) ALARM AI indicator light lit and courtesy message OPERATION WITHOUT AI indicator light unlit and no courtesy message TELEPHONE LINE (INST) AI indicator light lit and no courtesy message REPEATS OF COURTESY...
  • Page 22 ADVANCED PROGRAMMING “END ALARM” CODE … (from 1 to 3 digits; factory default 9) (INST) “EXCLUSION” CODE … (from 1 to 3 digits; factory default 1) (INST) RESTORE identification message FACTORY MESSAGES courtesy message (INST) (language: 00 Italian, 01 English, 02 German, LANGUAGE 03 French, 04 Polish, 06 Russian, 07 Spanish, (INST)
  • Page 23 (CLI) MULTI-LINK FUNCTION (from 0 to 9; 1=master, 0=function disabled) (INST) DTMF generated by GSM network DTMF GENERATOR DTMF generated by Helpy Controller SETTING (DTMF duration=X*50ms; from 1 to 9; (INST) factory default 2) LISTEN TO THE Digits Quality GSM SIGNAL...
  • Page 24 ADVANCED PROGRAMMING REGISTER THE GSM SATELITE TO SERVER COMNET (INST) DELETE THE GSM SATELLITE FROM SERVER COMNET (INST) LISTEN TO THE BATTERY LEVEL (expressed in mV) (INST) LISTEN TO THE EXTERNAL POWER SUPPLY (expressed in mV) LEVEL (INST) emergency-call button battery alarm periodic automatic test call 2W speaker unit connection failure alarm...
  • Page 25 Programming via e-stant software It is possible to program Helpy Controller via computer by using the USB/serial proprietary cable and the dedicated e-stant software. e-stant software also allows to: - update the firmware of the Helpy Controller - customize the messages of the Helpy Controller.
  • Page 26 SMS. Programming via SMS is possible by any mobile phone or other device supporting SMS. An SMS notifying the programming was performed is sent by the Helpy Controller to the number that sent the programming. ATTENTION Programmed performed via SMS sent from the Internet could not have a positive result if the required format is not followed.
  • Page 27: Local Use

    EXTERNAL CALLS <TELEPHONE NUMBER> Use remotely with Helpy Controller at rest  Call Helpy Controller and wait for a response.  Listen to the elevator identification message, if present.  Dial: to speak with the cabin speaker unit (ID 01)
  • Page 28  Dial <password> (factory default: ) to access programming.  All of the programming and functions below can now be performed: USE REMOTELY WITH HELPY CONTROLLER AT REST PROGRAMMING … CABIN SPEAKER UNIT (ID 01) SPEAKER UNIT (ID 02) CONVERSATION...
  • Page 29 SIGNALS LED signalling device status (red) Normal operation (no alarm) Alarm Voice connection Battery disconnected or low battery (max. 1-hour operation in idle state) 2W speaker unit connection error or bus problem Absence of telephone line Button failure LED signalling data transmission (white) Data transmission in progress GSM Satellite registered to COMNet Server...
  • Page 30 LED signalling GSM Satellite signal strength (green) No signal Low signal level Medium signal level Good signal level High signal level Note: the green LED on GSM satellite turns on during a call or when the local telephone is used. LED signalling alarm / periodical test call (yellow) Emergency-call alarm...
  • Page 31 LED signalling power supply status (blue) The external power supply is connected and the battery has max capacity charge The external power supply is connected and the battery has good capacity charge The external power supply is connected and the battery has medium capacity charge The external power supply is connected and the battery has low capacity charge...
  • Page 32 LED signalling GSM Satellite status (red) GSM Satellite correctly registered on the network GSM Satellite registering to the GSM network – GSM Satellite not registered correctly – PIN request – PIN incorrect – Other problems Call in progress Given alarm indicator light (yellow) Alarm Received alarm indicator light...
  • Page 33: Eu Declaration Of Conformity

    EU DECLARATION OF CONFORMITY Hereby, Esse-ti S.r.l. declares that the equipment type Helpy Controller is in compliance with Directives 2014/30/EU - 2014/33/EU - 2014/35/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/dichiarazioni-di-conformita...
  • Page 34 NOTE Page 34 NOTE...
  • Page 35 NOTE Page 35...
  • Page 36 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) – ITALY Tel. +39 071 7506066 Fax +39 071 7506057 www.esse-ti.it support@esse-ti.it...

This manual is also suitable for:

Helpy controller

Table of Contents