Ellison 16580 Mounting Instructions page 2

60 slot die storage wall rack

Advertisement

(3)
(1)
(1)
(3)
(5)
Figure C
Figure D
Note: The two Z-Clips are not bearing any of the Wall Rack's weight but are there to prevent any uninten-
tional lifting of the Wall Rack, which can cause it to become of the Wall Rack, which can cause it to become
disengaged from the Z-Bar. When installing multiple racks, the two Z-Clips on the bottom of each additional
Wall Rack are not attached to the wall. Insted, the Z-Cips tuck behind the Wall Rack below to prevent it from
becoming disengaged from the wall.
10. For mounting additional Wall Racks in a stacked position, repeat steps 3 through 8, using the top of the previously
hung Wall Rack as the starting point from which to measure up 11".
Ellison will repair or replace this product if, within one year of our purchase of this product, you discover a manufacturing defect and return the product to
Ellison along with your written proof of purchase. All returns must be made within one year of your purchase of this product. Unless otherwise specified in
writing, all such returns must be made to Ellison Educational Equipment, Inc., 25862 Commercentre Drive, Lake Forest, California 92630 USA. This warranty
is expressly limited to manufacturing defects and does not include any damage or defect caused in any manner after your purchase of this product. Other
than the express limited warranty set forth above, to the maximum extent permitted by applicable law, Ellison and its affiliates disclaim all express or implied
warranties. NO WARRANTIES ARE MADE WITH RESPECT TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE.
©2008 Ellison All rights reserved.
Ellison
Die Storage Wall Rack
®
(3)
6. Place grooved bottom edge of Z-Bar on wall level line (Figure A).
Black Line
(4)
Step 2
7. Insert the 1" Wood Screws (Item 5) into the pre-drilled holes at
Level Line
Wall
11"
8. Place Wall Rack onto the Z-Bar, making sure the pre-mounted
(3)
(5)
9. Once the Wall Rack is in final position, mark and drill a
(6)
(4)
Step 1
LIMITED WARRANTY
16580 Ellison 60 Slot Die Storage Wall Rack
25862 Commercentre Drive • Lake Forest, CA 92630-8804 USA
Within USA 800.253.2238 • Outside USA 949.598.8822
Secure one end of the Z-Bar (Item 2) to the wall using 2" Wood
Screws provided (Item 4). (Do not completely tighten this Screw,
but leave a little play to allow for leveling). Level the Z-Bar and
drive a second 2" Wood Screw (Item 4) onto the other end of the
Z-Bar. Finish tightening the first 2" Wood Screw and drive the
third Screw into the middle stud or wall anchor (Figure B).
the bottom of the Wall Rack in order to attach the grooved
bottom edge of the two remaining Z-Clips (Figure C, Item 3).
(The Wall Rack comes with three Z-Clips installed along the top
of the backside).
Z-Clips on back interlock securely with the Z-Bar (Figure D).
through the two bottom Z-Clips (installed in Step 7) into the wall.
Secure to wall using remaining 2" Wood Screws (Item 4). If the
Wood Screws are not in studs, use a Wall Anchor (Item 6) to
secure them to the wall (Figure D).