Xintex CMD5-RBI Owner's Manual

Rv carbon monoxide alarm

Advertisement

RV Carbon Monoxide Alarm
CMD5-RB (RV, Battery)
CMD5-RB-B (RV, Battery, Black Housing)
CMD5-RBI (RV, Battery, Interconnect)
CMD5-RBI-B (RV, Battery, Interconnect, Black Housing)
CMD5-RD (RV, 12/24 VDC)
CMD5-RD-B (RV, 12/24 VDC, Black Housing)
CMD5-RDI (RV, 12/24 VDC, Interconnect)
CMD5-RDI-B (RV, 12/24 VDC, Interconnect, Black Housing)
Owner's Manual
&
Installation Instructions
Tested by ETL to UL STD 2034 RV
Certified by ETL to CSA 6.19.01
ATTENTION!
Read and comply with all instructions, warnings and limitations before
installing, servicing or removing this device.
Additional copies of this manual are available at no charge by contacting the manufacturer,
distributor or dealer. Fireboy-Xintex reserves the right to change features without notice.
1
Part Number 18150, E, 02/07/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMD5-RBI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Xintex CMD5-RBI

  • Page 1 Read and comply with all instructions, warnings and limitations before installing, servicing or removing this device. Additional copies of this manual are available at no charge by contacting the manufacturer, distributor or dealer. Fireboy-Xintex reserves the right to change features without notice. Part Number 18150, E, 02/07/2018...
  • Page 2: Table Of Contents

    Single CO Alarm Interconnected CO Alarms Maintenance In the Event of an Alarm Deactivating Xintex Carbon Monoxide Alarm in End of Life Repairing Xintex Carbon Monoxide Alarms Returning Xintex Carbon Monoxide Alarms 1 Year Limited Warranty Part Number 18150, E, 02/07/2018...
  • Page 3: General Information

    SOURCE, AND FOR MAXIMUM EFFECTIVENESS, BE POWERED AT ALL TIMES. THIS DEVICE SHALL NOT BE INSTALLED OR USED IN AIRCRAFT AND/OR RACING VEHICLES. FIREBOY-XINTEX RESERVES THE RIGHT TO CHANGE FEATURES WITHOUT NOTICE. THIS ALARM WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS AT THE SENSOR.
  • Page 4 General Information Continued CAUTION: THERE ARE NO USER OR FIELD SERVICEABLE PARTS IN THIS PRODUCT. THE CO ALARM MUST BE RETURNED TO THE MANUFACTURER FOR ANY REPAIR OR PERFORMANCE CHECKS. THIS PRODUCT IS NOT INTENDED FOR USE IN ORDINARY OUTDOOR LOCATIONS OF FAMILY LIVING UNITS.
  • Page 5 Table 1 200 PPM: Slight headache within 2 to 3 hours. 400 PPM: Frontal headache within 1 to 2 hours. 800 PPM: Dizziness, nausea and convulsions within 45 minutes. Insensible within 2 hours. 1600 PPM: Headache, dizziness and nausea within 20 minutes. Death within 30 minutes.
  • Page 6 The CMD5-RBI, CMD5-RDI, CMD5-RBI & CMD5-RDI are designed to interconnect with other CMD5-RBI, CMD5-RDI, CMD5-RBI & CMD5-RDI. If the unit senses CO at an alarm level, it will communicate with other interconnected units and send them into alarm. The unit that senses CO will have a distinct LED pattern compared to the interconnected units.
  • Page 7: Specifications

    Alarm Horn: ≈ 85dB @3.05M Dimensions: 3.5” (89mm) x 3.5” (89mm) x 1.25” (32mm) Housing Material: Polylac PA-765(ABS-FR) System Specifications (CMD5-RBI & CMD5-RBI-B) Operating/Storage Temperature: -40°F (-40°C) to 158°F (70°C) Alarm Points: Time Weighted Average (TWA) Alarm @ 10% COHb (<15min @ 400 PPM) Alarm Horn: ≈...
  • Page 8: Operation Of Xintex Carbon Monoxide Alarm(S)

    Operation of Xintex Carbon Monoxide Alarm(s) Horn Power Indicator Danger Indicator Test/Mute Button The CO Alarm uses a microprocessor to measure and accumulate CO levels. Using the principle of “time-weighted averaging” (TWA), the CO Alarm monitors CO concentrations, temperature, and time to calculate levels of carboxyhemoglobin (COHb).
  • Page 9 Status Indicators and Explanations SYSTEM Green LED Red LED AUDIBLE STATUS INDICATOR INDICATOR HORN Normal: 1 Flash/180 sec. Alarm: 1 Flash/5 sec. 4 Beeps, 5 sec. Silence Remote Alarm: 1 Flash/5 sec. 1 Flash/5 sec. 4 Beeps, 5 sec. Silence End of Life 1 Flash/5 sec.
  • Page 10 Operation of Xintex Carbon Monoxide Alarm(s) Continued Normal The Green LED will flash once every 180 seconds (3 minutes) while in normal operation. Alarm When the CO Alarm enters the danger alarm, the Danger (!) indicator is flashing red and the horn beeps 4 times and pauses for 4-5 seconds in a repeat pattern.
  • Page 11: Locating A Xintex Carbon Monoxide Alarm

    DURING EOL RESET THE UNIT WILL GO THROUGH A SELF-DIAGNOSTIC PROCESS FOLLOWED BY THE TEST SEQUENCE. Locating a Xintex Carbon Monoxide Alarm Because of the high risk of carbon monoxide injuries due to the nature of recreational vehicles, we recommend a carbon monoxide alarm be installed in the main accommodation area and in each sleeping area of the recreational vehicle.
  • Page 12: Installation

    Installation Installing the Mounting Base  Mounting Base should be installed vertically when installing CO Alarm on a wall.  Use appropriate length #6, Pan Head screws to secure Mounting Base.  Do not over-tighten.  Drill appropriate size hole (0.38” (9.5mm) Max) for wired models to accommodate the wires.
  • Page 13: Power Connections (Cmd5-Rd, Cmd5-Rdi, Cmd5-Rd-B & Cmd5-Rdi-B)

     Press CO Alarm against mounting surface and turn clockwise, approximately 25°. After installation is complete, attach one of the enclosed “Warning” stickers to the wall next to the alarm. Place the other sticker near a source of fresh air where you would gather after an alarm indicates the presence of carbon monoxide.
  • Page 14: Interconnect Wiring (Cmd5-Rbi, Cmd5-Rdi, Cmd5-Rbi-B & Cmd5-Rdi-B)

    Installation Continued Interconnect Wiring (CMD5-RBI, CMD5-RDI, CMD5-RBI-B & CMD5-RDI-B) Brown and Yellow 18 GA wires are provided for interconnecting CO Alarms. Connect the Brown wires and Yellow wires of up to 10 units to each other. Brown (Int -) Yellow (Int +)
  • Page 15: Testing

    Testing Test device operation after vehicle has been in storage, before each trip, and at least once per week during use. Single CO Alarm Press “Test/Mute” button until Green LED turns on and release. The alarm will simulate 2 alarm cycles (2 sets of 4 Beeps, 5 sec. Silence between). The Red LED will flash once every 5 seconds.
  • Page 16: Deactivating Xintex Carbon Monoxide Alarm In End Of Life

    CAUTION: DEACTIVATING CO ALARM IS PERMINANT. REACTIVATING IS NOT POSSIBLE. Repairing Xintex Carbon Monoxide Alarms Xintex Carbon Monoxide Alarms are not field serviceable. Components must be returned to the factory for any repairs. Returning Xintex Carbon Monoxide Alarms No product may be returned for credit or repair without a written “Returned Material Authorization”...
  • Page 17: Year Limited Warranty

    Fireboy-Xintex LLC any other liability in connection with the sale of its products; Fireboy-Xintex LLC shall not be liable for the loss of use, revenue, or profit or for any injury, or for any other consequential or incidental damages, buyer is not relying on seller’s judgment regarding his or her particular requirements, and has had an opportunity to inspect the product to his or her satisfaction.

Table of Contents