FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/spa service
technician. The procedures in this manual must be followed exactly. Failure to follow warning notices
and instructions may result in property damage, serious injury, or death. Improper installation and/or
operation will void the warranty.
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac ePump

  • Page 1 Installation and Operation Manual ePump™ Variable Speed Pump User Interface WARNING FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/spa service technician. The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.
  • Page 3: Table Of Contents

    Table of Contents Section 1. Important Safety Instructions ..4 Section 5. Service Setup Options ....14 Entering Service Setup ........14 Section 2. Installation of the ePump Minimum and Maximum Pump Speeds ..14 Controller .......... 6 Load Defaults ..........14 Introduction ............
  • Page 4: Section 1. Important Safety Instructions

    Page 4 Important Safety Instructions Section 1. READ AND FOLLOW ALL INSTRUCTIONS All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub.
  • Page 5 Page 5 WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
  • Page 6: Section 2. Installation Of The Epump Controller

    WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the ePump™ Figure 1. Zodiac ePump™ Variable Speed Pump electrical circuit before starting the procedure. Failure to...
  • Page 7: Installation Of The Backplate On A Flat Wall

    WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the ePump™ electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
  • Page 8: Connection To Remote Contacts

    WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the ePump™ electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
  • Page 9: Remote Closure 4 Application - Booster Pump Support

    WARNING The ePump™ Controller Interface ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the ePump™ The ePump™ controller interface panel electrical circuit before starting the procedure. Failure to provides both timed and manual speed controls for the comply may cause a shock hazard resulting in severe ePump™.
  • Page 10: Basic Functions

    Page 10 Basic Functions RUN Mode The ePump™ has two (2) operational modes: When the pump is running (not off), the User Mode and Setup Mode. controller displays , where N:LABEL/00:00 RPM:xxxx n:label is the number and label of the selected preset, 3.3.1 User Mode...
  • Page 11: Pump Speed Setting

    ON TIME as 12:00AM (midnight)  starting the pump, press any button " " through "4". and set the ePump OFF TIME as 8:00AM. Pump Speed Setting Please note this does not mean the filtration will operate at midnight. It indicates the epump will ...
  • Page 12: Remote Operation

    Page 12 Using the arrow keys, select 4.5.3 Manually Overriding a Timer TIMECLOCK Select using the arrow keys. The program is Program ENABLE  now enabled to run. Press the preset button (" " or Timeclock programs may be prematurely "2") to return to the mode.
  • Page 13: Pump Freeze Protect

    Page 13 Pump Freeze Protect To help protect against pump damage, the controller monitors the temperature inside the pump. If enabled, pump freeze protect will start the pump at the eStar speed when the temperature approaches freezing. The pump will then run for a duration set by the installer.
  • Page 14: Section 5. Service Setup Options

    SET MAx LIMIT keys. Press . Using the arrow keys, set the MENU NOTE The ePump™ controller must be in the OFF maximum speed to the desired value. Press MENU mode (all LED's lights must be off) before accept and store.
  • Page 15: Last Fault

    MENU Priming Speed and Duration The ePump™ controller will command the ePump™ to operate at the priming speed for the priming duration specified (except during timer program overlaps or follow-on commands where the pump is not stopped before changing speeds). From the service setup menu, select using the arrow keys.
  • Page 16: Estar Speed

    When enabled to do so, the ePump™ controller monitors the temperature inside the pump and will activate the ePump™ at the eStar speed when the temperature approaches freezing. The run duration of the pump freeze protect operation is adjustable from 30 minutes to 8 hours, or may be disabled completely.
  • Page 17: Setting Time-Of-Day

    Using the arrow keys, change the character as desired. Press to accept the change and advance MENU The ePump™ controller comes from the factory  to the next character position. Press any preset key " " with pre-programmed labels or names for the preset through "4"...
  • Page 18: Display Light Control

    Page 18 Display Light Control Run Duration (Presets 3 and 4 Only) The controller’s display is equipped with a Presets "3" and "4" may be programmed to run backlight to aid viewing in low light conditions. for a specified duration after being manually started. This run duration is programmable from 30 minutes to From the setup menu, select DISPLAY LIGHT...
  • Page 19: Section 7. Menu Flow Chart

    Page 19 Section 7. Menu Flow Chart...
  • Page 20 Zodiac Group Australia Pty Ltd 219 Woodpark Road, Smithfield NSW 2164 Ph: 1800 688 552 Fax: 02 9756 3987...

Table of Contents