  • Page 1 XR 3700 Real-Time X-Ray Inspection System (PN 8007-0542, 120V) (PN 8007-0546, 230V) XR 3500 Real-Time X-Ray Inspection System (PN 8007-0540, 120V) (PN 8007-0544, 230V) This manual operation is for PACE’s XR 3500 50kv unit and PACE’s XR 3700 70kv unit.
  • Page 2: Table Of Contents

    Radiation Safety Information……………………………………...…..4 Radiation Safety Guidelines…………………………………..….…...6 XR 3700 Specifications……………………………………………..7 Features……………………………………………………………...……7 System Operation…...…………………………….…………………….8 Set-up……………………………………………………………………...9 XR 3700 Initial Power-up and Operational Test……………………10 XR 3700 Maintenance…………………………………………………..11 XR 3700 Troubleshooting……………………………………………...12 Design Safety Standards and Safe Operating Practices………...13 Service and Warranty…………………………………………………...15 PACE contact information and trademarks………………………...16...
  • Page 3: Xr 3700 Safety Information

     PACE strongly recommends that all maintenance be performed by a qualified service technician.  The XR 3700 x-ray tube produces high voltages of up to 70,000 volts. The XR 3500 X-ray tube produces high voltages of up to 50,000 volts. Under no circumstances should the case be disassembled or modified as severe electrical shock may occur.
  • Page 4: Radiation Safety Information

     The radiation exposure dosage received by personnel working with x-ray inspection equipment should not exceed those limits set by local regulations relating to ionizing radiation.  Adequate warning signs and symbols should be displayed in the vicinity of the XR 3500/3700 warning of possible x-ray exposure. Any warning lamps and signals should be checked prior to operating the XR 3500/3700.
  • Page 5 Warning: Failure to adhere to the following warnings may result in exposure to radiation:  Do not operate the x-ray system unless all system components and features are in good repair.  Never attempt to remove any system component or bypass any system function.
  • Page 6: Radiation Safety Guidelines

    Radiation Safety Guidelines To ensure the health and safety of the operator and all others in the vicinity of operating x-ray inspection equipment, the following guidelines are recommended for establishing a basic radiation safety program. Note: Federal, State, and some local government agencies may have more stringent regulations concerning the operation and use of equipment that produces ionizing radiation (x-rays).
  • Page 7: Xr 3700 Specifications

    6. Service of the equipment should only be performed by or under the instruction of trained PACE personnel. Many users choose to issue periodic radiation film badges to assure employees that they are not being exposed to significant levels of radiation and to provide added assurance that radiation emissions are well within regulatory limits.
  • Page 8: System Operation

    6. System Operation XR 3500/3700 The XR 3500/3700 Real Time Inspection System is a powerful tool in the quality control and process verification of all aspects of microelectronics manufacturing. The XR 3500/3700 provides rapid, real-time x-ray inspection for Bare Board production and rework environments.
  • Page 9: Set-Up

    7. Set Up A. XR 3500/3700 as a stand-alone inspection station Place the XR 3500/3700 on a stable work platform of sufficient capacity to adequately support the XR 3500/3700. The monitor used to view the images should be placed on the work surface next to the XR 3500/3700 and not on top of the XR 3500/3700, as it is not designed to support a monitor and the monitor may fall.
  • Page 10: Xr 3700 Initial Power-Up And Operational Test

    The other end of the composite video cable should be connected to the composite video input on the video capture card on the PC. See Figure 2. The power cord should be connected to a properly grounded 120 VAC power supply. Composite Video Connection Figure 2: Back of TF 1700/2700 PC or IR 3000.
  • Page 11: Xr 3700 Maintenance

    The window is made of a lead-impregnated acrylic resin; NEVER allow solvents that will attack acrylic to be used near the window. If you find that your system is coming close to its calibration date, please contact PACE to schedule a calibration.
  • Page 12: Xr 3700 Troubleshooting

    In the event that your system exhibits problems, this section will familiarize you with the basic steps to troubleshoot the Quick Tips problem as well as what information PACE will require in order to give you the best The first thing to do is to simply possible service.
  • Page 13: Design Safety Standards And Safe Operating Practices

     Does the systems image processor boot up?  Does the X-ray monitor have a light gray screen or flicker? X-Ray: The x-ray category covers the problems that affect the tube’s emission of x-rays. The x-ray category includes: - The red “X-Ray On” light is not turning on. - There is no image on the monitor, but video signal is present.
  • Page 14 (milli Roentgens per hour). It is generally a good idea to have, as part of a radiation safety program, a radiation survey meter. The monitor –4EC survey meter is available from PACE. The Monitor-4EX employs an energy compensated G-M tube to measure the presence of radiation.
  • Page 15: Service And Warranty

    Warranty service may be obtained by contacting the appropriate PACE Company or local Authorized PACE distributor as set forth below to determine if return any item is required or, if repairs can be made, by the user in the field.
  • Page 16: Pace Contact Information And Trademarks

    (44) 1908-277666 Fax: (301) 498-3252 (44) 1908-277777 PACE Incorporated retains the right to make changes to specifications contained herein at any time, without notice. Contact your local authorized PACE Distributor or PACE Incorporated to obtain the latest specifications. The following are trademarks and/or service marks of PACE, Incorporated, MD, USA.