Do you have a question about the B 600 M and is the answer not in the manual?
Questions and answers
Summary of Contents for Greiner Vibrograf B 600 M
Page 1
Vibrograf B 600 M / Q User manual User manual User manual User manual Helmut Klein GmbH Tel. +49 7231 9535 0 Fritz-Neuert-Strasse 31 Fax +49 7231 9535 95 Greiner 75181 Pforzheim info@klein-messtechnik.de Germany www.klein-messtechnik.de Operating - Manual B 600 M / Q...
Fuse box See page 15 with integrated mini fuse: 630 mA for 230 Volt. Main connection 230 V/ 50 Hz 1.25 A for 115 Volt optional 115V / 50-60 Hz Operating - Manual B 600 M / Q...
= Turn the Level knob c.c.w. time time Amplitude Amplitude + / - sign deviation value = Turn the Level knob c.w. = Value of ( MS WINDOW ) is too high Operating - Manual B 600 M / Q...
MP86M. Light barrier for clocks. The light barrier may be connected to the 15 pin male plug on the rear of the B 600 instead of the MP86M. Light barrier Operating - Manual B 600 M / Q...
Press - MENU + or MENU - Until the desired sign appears. g. Go on this way until the text looks as you wish. h. Press - PRINT / PRINT / MENU - The selection will be stored. Operating - Manual B 600 M / Q...
50 ° 1 8 Set the desired MST 1.8 Set the desired MST N ( STEP ) 21600 LIFT ANGLE and BEAT FREQUENCY SELECT ACTUAL RUN PARAMETERS See next page for explanations ! Operating - Manual B 600 M / Q...
Page 8
MS WINDOW: 100° 28800 36000 28800, 36000, SELECT ACTUAL RUN PARAMETERS In RUN MODUS ( N FIXED) The beat can be set manually from 3240 up to 39600 in N ( FINE ) Operating - Manual B 600 M / Q...
DIAGRAM SINGLE BEAT DIAGRAM SINGLE BEAT press PRINT to display the single beat. press START/STOP to return to the main menu PRESS START/STOP KEY TO COMPLETE . . . Escape system of the watch. Operating - Manual B 600 M / Q...
Page 10
( 1 ) figure 1 But it's impossible with a escapment noise as you can see in figure ( 2 ) figure 2 Operating - Manual B 600 M / Q...
Page 11
SELECT ACTUAL RUN PARAMETERS SELECT ACTUAL RUN PARAMETERS figure 6 To save the new value of MS WINDOW when in the above menu, Press ( PRINT ) first and then ( MENU - ) Operating - Manual B 600 M / Q...
The clamp-microphone may be connected to the 15 pin male plug on the rear of the B 600 instead of the MP86M. Light barrier for clocks. The light barrier may be connected to the 15 pin male plug on the rear of the B 600 instead of the MP86M. Operating - Manual B 600 M / Q...
Connect here the cable between B 600 and microphone. 13.05.23 Quartz watch Quartz watch LCD watch measures the measures the measures the motor quartz frequency impulses frequency 4.19 MHz 32 kHz Operating - Manual B 600 M / Q...
( t bilit lt ) And the (DSP Y Gain to 20 ) By changing the ( DSP Y GAIN ) „Display gain „ the grafic line will change. Please try once Operating - Manual B 600 M / Q...
The higher you set the (DSP Y GAIN) value , The higher is the resolution of the displayed grafic The higher is the resolution of the displayed grafic. B 600 Q 0.12 s/d B 600 Q 0.12 s/d Operating - Manual B 600 M / Q...
Page 16
. This means , the internal quarz frequency will be adjusted. To calibrate the instrument correctly ,you neet a master signal , e.g. DCF77. The calibration is reserved for service only Operating - Manual B 600 M / Q...
32 kHz quartz frequency 4 19 MHz quartz frequency 4.19 MHz quartz frequency frequency of digital display motor impulses Optional devices: clamp microphone optical system for clocks Operating - Manual B 600 M / Q...
Need help?
Do you have a question about the B 600 M and is the answer not in the manual?
Questions and answers