INSTALLATION
Fastlane
Remote Control
Setting new standards in entrance control
®
Fastlane
is a registered trademark of Integrated Design Ltd 1995
Confidential
ISSUE
DATE
A4
06-2008
A5
10-2008
A6
08/04/10
Manufactured By:
Integrated Design Ltd, Feltham Point, Browells Lane,
Feltham, Middlesex, TW13 7EQ, United Kingdom
Tel: (+44) (0)208 890 5550
Fax: (+44) (0)208 890 2444
E-mail: info@idl.co.uk
Web: www.fastlane-turnstiles.com
®
CHANGE
Standard Text Formatting, includes Illustrations/Photos
Made the manual more generic for the entire Fastlane range
Update Contact Details and Warranty
REF
CN1297
CN1358
CN1627

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fastlane and is the answer not in the manual?

Questions and answers

Summary of Contents for Integrated Design Ltd Fastlane

  • Page 1 ISSUE DATE CHANGE 06-2008 Standard Text Formatting, includes Illustrations/Photos CN1297 10-2008 Made the manual more generic for the entire Fastlane range CN1358 08/04/10 Update Contact Details and Warranty CN1627 Manufactured By: Integrated Design Ltd, Feltham Point, Browells Lane, Feltham, Middlesex, TW13 7EQ, United Kingdom...
  • Page 2: Table Of Contents

    Commissioning ....................11 Precautions ....................11 Preparation ....................11 Procedure ..................... 11 Technical Specification ..................12 Warranty ......................13 Technical Support ....................13 Important Notice ....................13 Page 2 of 13 Issue A6 April 2010 © Integrated Design Ltd Confidential...
  • Page 3: Introduction

    The aim of this manual is to provide sufficient information for suitably qualified personnel to install and commission one or more of Integrated Design’s Remote Control Panels. ® The Remote Control is designed for use only with the IDL range of Fastlane products. Figure 1 - Remote Control (example of 2-lane enclosure) It is a small desktop console that provides the following functions: •...
  • Page 4: Installation Procedure

    3-lane 168mm 304.5mm 6 5/8 “ 12” 4-lane 404mm 15 7/8” For installations with more than 4 lanes, a series of enclosures would need to be used. Page 4 of 13 Issue A6 April 2010 © Integrated Design Ltd Confidential...
  • Page 5: Remote Control Wiring Connections

    Remote Control. Alarm Indication ® The AL2 terminals on the Remote Control are connected to the Fastlane CPU Card AL2 output, operating in the Normally Open mode. Figure 5 - Wiring Connection for Alarm Indication (Remote PCB reverse view) ©...
  • Page 6: Visitor Entry/Exit

    ® ® Fastlane CPU Card AUX1 and AUX2 outputs. Assuming the Fastlane Pedestals are installed in the recommended configuration (Receive Pedestal on the right-hand side as you enter the building/secure area): AUX1 is for Visitor Entry, AUX2 is for Visitor Exit.
  • Page 7: Power

    CPU Card or a third party PSU. The 12V ‘+’ and ® ‘-’ terminals are connected to one of the Fastlane CPU Card PWR outputs. Ensure the correct polarity before connecting, and use suitable cabling for the required distance. Technical specifications are at the end of this manual.
  • Page 8 Fastlane Remote Control INSTALLATION MANUAL Confidential ® Figure 8a - Wiring Connection for Power from Fastlane CPU Card (Remote PCB reverse view) Figure 8b - Wiring Connection for Power from 3 Party PSU (Remote PCB reverse view) Page 8 of 13 Issue A6 April 2010 ©...
  • Page 9 Fastlane Remote Control INSTALLATION MANUAL Confidential ® Figure 8 - Fastlane Connection Overview (example with Glassgates) ® Please see the relevant Installation Manual for alternative Fastlane examples © Integrated Design Ltd Issue A6 April 2010 Page 9 of 13 Confidential...
  • Page 10: Operation

    A momentary push (1-second) on the Enter button will allow timed-visitor access. During timed ® access, the Fastlane turnstile will wait for a person to use the lane or will time out and return to normal operation. The time-out period is adjusted inside the turnstile; please see the appropriate installation manual for more information.
  • Page 11: Commissioning

    Preparation ® This procedure is to be conducted once the Fastlane turnstiles have been installed and confirmed working. The Remote Control should be in the desired location with all connections intact and the plastic ends replaced (you may wish to screw the ends on only after confirming the unit is working).
  • Page 12: Technical Specification

    1 Volt-free Normally Open (NO) Contact, closing on Alarm Alarm Indicator: 12V 80mA bulb 2 Normally Open (NO) Contacts. 1A at 28Vdc Outputs: 1 Changeover Contact. 1A at 28Vdc Page 12 of 13 Issue A6 April 2010 © Integrated Design Ltd Confidential...
  • Page 13: Warranty

    Company. The terms of warranty are as per Integrated Design Ltd. Conditions of Sale and will not apply to any product, which has been modified, or improperly used or repaired after leaving the Company's control.