Parameter CONDITIONS data type structure part 1 (start conditions)
Parameter
STARTCOND
IDLETIME
STARTCHAR
STRSEQ1CTL
STRSEQ1
STRSEQ2CTL
STRSEQ2
STRSEQ3CTL
STRSEQ3
STRSEQ4CTL
STRSEQ4
S7-1200 Programmable controller
System Manual, 11/2009, A5E02486680-02
ignored are not required to be part of the message. Any trailing characters that are
ignored are required to be part of the message.
Parameter
type
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
Data type
Description
UInt
Specify the start condition:
01H - Start Char
02H - Any Char
04H - Line Break
08H - Idle Line
10H - Sequence 1
20H - Sequence 2
40H - Sequence 3
80H - Sequence 4
UInt
The number of bit times required for idle line timeout.
Only used with an idle line condition. 0 to 65535
Byte
The start character used with the start character
condition.
Byte
Sequence 1 ignore/compare control for each character:
These are the enabling bits for each character in start
sequence
01H - Character 1
02H - Character 2
04H - Character 3
08H - Character 4
10H - Character 5
Disabling the bit associated with a character means
any character will match, in this sequence position.
Char[5]
Sequence 1 start characters (5 characters)
Byte
Sequence 2 ignore/compare control for each character
Char[5]
Sequence 2 start characters (5 characters)
Byte
Sequence 3 ignore/compare control for each character
Char[5]
Sequence 3 start characters (5 characters)
Byte
Sequence 4 ignore/compare control for each character
Char[5]
Sequence 4 start characters (5 characters)
Point-to-Point (PtP) communications
8.7 Point-to-Point instructions
257