Compressed Air Advisors HEF 005 Maintenance And Operating Manual

Compressed Air Advisors HEF 005 Maintenance And Operating Manual

Compressed air filter

Advertisement

COMPRESSED AIR FILTER
HEF 005÷240
M A I N T E N A N C E A N D O P E R A T I N G M A N U A L
38178800738
Original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEF 005 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Compressed Air Advisors HEF 005

  • Page 1 COMPRESSED AIR FILTER HEF 005÷240 M A I N T E N A N C E A N D O P E R A T I N G M A N U A L 38178800738 Original instructions...
  • Page 3: Table Of Contents

    INTRODUCTION ..................2 SAFETY......................2 INTENDED USE .................... 2 FILTRATION GRADES AND APPLICATIONS ........3 INSTALLATION.................... 4 1.1 Models HEF 005 - 070 ............4 1.2 Models HEF 094 - 240 ............4 1.3 Starting up................5 1.4 Operation ................5 1.4.1 Condensate discharge ..................6 MAINTENANCE....................
  • Page 4: Introduction

    The Manufacturer cannot be held responsible for any damage resulting from improper, incorrect or unreasonable use. HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 5: Filtration Grades And Applications

    0,005 mg/m HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 6: Installation

    Pressurize the plant like shown at paragraph "Starting up" and check for air leakage. HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 7: Starting Up

    If a filter grade A is installed, check the good efficiency of the pre-filters, otherwise the presence of any oil and water aerosols make the absorption power of the filter void. HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 8: Condensate Discharge

    See the instructions enclosed with the discharger for operation and installation. Fig. 3 Fig. 2 Fig. 1 Fig. 5 Fig. 4 Fig. 6 HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 9 ATTENTION! Never proceed service and maintenance work, if device is still under pressure. HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 10: Maintenance

    Always respect the regulations in force for disposing of polluting materials such as filtering elements etc. HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.
  • Page 11: Technical Data

    A Flow rate Filter Pipe size Dimension [mm] Volume Mass housing model [Rp] D min [Kg] 3/8” 0,47 HEF 005 1/2” 0,47 HEF 007 3/4” 0,60 HEF 010 1” 1,57 HEF 018 1” 2,20 HEF 030 11/2”...
  • Page 12 0,38 0,50 0,63 0,75 0,88 1,00 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13 factor 1/2” HEF 005÷240 The data in this manual are not binding and may be changed by the manufacturer without notice. Reproduction of this manual is strictly prohibited.

Table of Contents