Kooltronic KP2E192/40 Operator's Manual

Packaged blowers

Advertisement

Quick Links

OPERATOR'S MANUAL
CAUTION
BEFORE INSTALLING AND
USING THIS AIR CONDITIONER,
IT IS IMPORTANT THAT THIS
MANUAL BE READ AND
UNDERSTOOD THOROUGHLY
900-057-04 (12/18)
(CDR: 20111)
Keep This Manual
With Pagoda
PAGODA SERIES
Pagoda Series
Packaged Blowers
Find additional information on this
model at kooltronic.com, or use the
Technical
Documents
below.
Technical
Documents
KOOLTRONIC, INC.
30 Pennington-Hopewell Road
Pennington, NJ 08534
609 • 466-3400
FAX: 609 • 466-1114
www.kooltronic.com
QR
code

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KP2E192/40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kooltronic KP2E192/40

  • Page 1 Pagoda Series Packaged Blowers Find additional information on this Keep This Manual model at kooltronic.com, or use the Technical Documents code below. With Pagoda Technical Documents PAGODA SERIES OPERATOR'S MANUAL CAUTION KOOLTRONIC, INC. 30 Pennington-Hopewell Road BEFORE INSTALLING AND Pennington, NJ 08534 USING THIS AIR CONDITIONER, 609 •...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Page Introduction Incoming Inspection III. Product Handling Product Identification and Nameplate Installation Instructions Drawings and Dimensions VII. Specific Model Data Technical Data Major Component Replacement VIII. Packing Procedure for Warranty Return Warranty I. Introduction This Manual provides you with the necessary general information for properly installing and operating Pagoda Packaged Blowers.
  • Page 3: Incoming Inspection

    CONCEALED DAMAGE An immediate claim MUST be filed with the freight carrier and an inspection requested. Retain all packing materials. Kooltronic cannot assume responsibility for Consignee's failure to file a timely freight claim. III. Product Handling Do not attempt to operate your Pagoda unit until you read and thoroughly understand this Manual.
  • Page 4: Drawings And Dimensions

    ENCLOSURE AIR INLET (4) .312 [7.0] DIA. HOLES 2.00 [50.8] DISCHARGE AIR OUTLET (ALL 4 SIDES) imensions, inches[mm] are for reference only and subject to change Model KP2E192/40 13.50 [342.9] 11.38 [289.1] 5.18 [131.6] 12.00 [304.8] 12.75 [323.9] KP2E220/45 13.50 [342.9] 11.38 [289.1]...
  • Page 5: Specific Model Data

    VII. Specific Model Data Technical Data* Approximate Weight CFM @ Cutoff Model Type 0" S.P. S.P. Amps Watts Lbs. KP2E192/40 2-Pole 1.72 63.6 0.74 KP2E220/45 2-Pole 1.94 68.6 1.05 KP2E225/40 2-Pole 1.71 71.7 1.11 KP2E225/63 2-Pole 2.66 73.4 1.89 KP2E250/56 2-Pole 2.68...
  • Page 6 This page intentionally left blank.
  • Page 7: Warranty

    THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS KOOLTRONIC RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.