User Manual
Rev C
Penn Photon Devices, LLC
1055 Mensch Dam Road
Pennsburg, PA 18073, USA
Tel: (011) 267-923-8798

Advertisement

Table of Contents
loading

Summary of Contents for Penn Photoreactor m2

  • Page 1 User Manual Rev C Penn Photon Devices, LLC 1055 Mensch Dam Road Pennsburg, PA 18073, USA Tel: (011) 267-923-8798...
  • Page 2: Table Of Contents

    Table of Contents Introduction ............................3 Safety ..............................3 Explanation of labels ........................4 System Overview ..........................5 Setup ..............................6 System Components ........................6 Choosing a Location ........................6 Connecting the Power Cord ......................6 Operation ............................. 7 Setup ............................7 Performing a Photoredox Cycle ....................
  • Page 3: Introduction

    1 Introduction The Photoreactor m2 is a benchtop instrument designed for chemists and researchers to accelerate chemical reactions using photoredox catalysis. The Photoreactor m2 combines LED illumination, mechanical stirring and cooling in one device. The user defined parameters of temperature, intensity, stir rate and time, creates a valuable tool for repeatability, traceability, efficiency and consistency of results.
  • Page 4: Explanation Of Labels

    The Illuminator unit requires adequate airflow to maintain proper cooling. Ensure the ventilation holes and bottom of the unit are unobstructed and a minimum of 4” clearance is provided in rear of unit. If the Illuminator is used in a manner not specified within this manual, the protection provided by the equipment might...
  • Page 5: System Overview

    3 System Overview Vial Holder Light Shield Reflector LED Module Touchscreen Base Unit...
  • Page 6: Setup

    Choosing a Location Set the Photoreactor m2 horizontally on its four neoprene feet on a flat surface in a place that allows for adequate air ventilation on the back and bottom. Do not place the Photoreactor m2 on top of paper or loose material that may be drawn into any ventilation port.
  • Page 7: Operation

    Power Switch K-type connector Power Supply Receptacle USB Receptacle The unit must be powered with the supplied power supply (85-264V, 50/60 Hz, Full Range). 5 Operation Setup Once the power cord is connected set the ON/OFF (I/O) switch to the ON (I) position. Add the contents to vial with appropriately sized stir bar (if required) and insert into the vial holder.
  • Page 8 Warning: To avoid damage to the device, ensure the thermocouple does not come into contact with any moving parts, i.e. stir magnet, motor or fan Thermocouple path...
  • Page 9: Performing A Photoredox Cycle

    Performing a Photoredox Cycle The user interface (GUI) initiates on the main display (shown left). The device is configured with the following default settings. • Duration (HH:MM:SS) is 01:00:00 • Post-cool duration (MM:SS) is 00:30 • LED intensity (%) is 50 •...
  • Page 10 To change the set point of a given parameter select it on the touch screen. This will provide a display corresponding to the parameter you have chosen as shown on the right. The dial may be rotated to select the desired setting.
  • Page 11: Termination, Turning The Unit "Off

    The Status field will indicate “Paused” and the Pause button will change to “Resume”. Press “Resume” to restart the device. The LED exposure and Time Remaining count will continue from the point in the cycle when it was paused. Opening the light shield during a cycle will also pause the device. Upon completion of a cycle, the unit will display status “Complete”.
  • Page 12: System Information

    • Never clean any internal electronics with liquid cleaners. If necessary, remove all dust from external surfaces with dry compressed air. • Photoreactor m2 units shall be disposed of via local and applicable regulations based on the intended use. 8 Maintenance The Photoreactor m2 is designed to operate for many years without any maintenance required.
  • Page 13: Technical Data

    Consult the manufacturer for further instructions. Contact Information: Penn Photon Devices, LLC 1055 Mensch Dam Road Pennsburg, PA 18073, USA Tel: (011) 267-923-8798 9 Technical Data Cover closed • Width: 12.2 cm (4.8 inches) •...
  • Page 14: Product Ratings

    10 Product Ratings For all CE compliance questions, EU customers may contact; Necsel IP, Inc., an Ushio Group company 101 Panton Road, Vergennes, VT 05491, USA Tel: (011) 802 877 2182...